1. Introduction
Thank you for choosing the Avalla S-80 Portable Air Conditioner. This 4-in-1 unit is designed to provide efficient cooling, dehumidification, fan circulation, and a quiet sleep mode for your comfort. With a powerful 5000 BTU cooling capacity, it is suitable for rooms up to 34m³. Please read this manual thoroughly before operation to ensure proper use, maintenance, and safety.

Image 1.1: Avalla S-80 Portable Air Conditioner and included accessories (exhaust hose, window bracket, remote control).
2. Important Safety Information
WARNING: Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire, and/or serious injury.
- This appliance is for indoor use only.
- Ensure the unit is placed on a flat, stable surface.
- Do not operate the unit with a damaged cord or plug.
- Keep the unit at least 50cm away from walls or other objects to ensure proper airflow.
- Do not block air inlets or outlets.
- The appliance uses R-290 refrigerant. Do not puncture the refrigerant circuit.
- Always unplug the unit before cleaning or performing any maintenance.
- Do not use chemical solvents or abrasive cleaners on the unit.
- Supervise children to ensure they do not play with the appliance.
3. Package Contents & Product Diagram
3.1. Package Contents
Verify that all items are present in the packaging:
- Avalla S-80 Portable Air Conditioner Unit
- Exhaust Hose
- Window Bracket
- Remote Control
- User Manual (this document)
3.2. Product Diagram

Image 3.1: Avalla S-80 unit with key dimensions (Height: 70cm, Width: 31cm, Depth: 31.5cm).
The unit features a top control panel, front air outlet, rear air inlet, and castor wheels for portability.
4. Setup and Installation
4.1. Unit Placement
Place the air conditioner on a firm, level surface in the room you wish to cool. Ensure there is at least 50cm of clear space around the unit for optimal air circulation.

Image 4.1: The portable air conditioner positioned in a living space, demonstrating its compact design and mobility on castors.
4.2. Exhaust Hose Installation
- Screw one end of the exhaust hose onto the hose connector.
- Attach the other end of the exhaust hose to the window kit adapter.
- Insert the hose connector into the exhaust air outlet on the back of the air conditioner unit.
- Adjust the window bracket to fit your window opening. The kit is designed for various window types, including sliding, casement, awning, and sash windows.
- Secure the window kit in place, ensuring a tight seal to prevent hot air from re-entering the room.

Image 4.2: The air conditioner properly set up with the exhaust hose venting hot air out of a window, illustrating efficient air management.
Video 4.1: An overview demonstrating the versatility of Avalla portable air conditioners for different room sizes and window types, including setup examples.
5. Operating Instructions
5.1. Control Panel and Remote Control
The Avalla S-80 can be operated using the touch control panel on top of the unit or the included remote control. The digital display shows the current temperature and settings.

Image 5.1: The air conditioner's digital display and remote control, highlighting ease of use and quiet operation for sleep mode.
5.2. Operating Modes
- Cool Mode: Provides powerful cooling down to 16°C. Use the temperature adjustment buttons to set your desired temperature. The unit will automatically cool the room to the set temperature.
- Fan Mode: Circulates air without cooling. Ideal for improving air circulation and freshness.
- Dehumidifier Mode: Removes excess moisture from the air, up to 12 litres per day. This helps prevent dampness and mould, and can assist in drying clothes indoors.
- Sleep Mode: Designed for quiet operation, reducing noise levels to approximately 50dB. The display dims, and the unit maintains a comfortable temperature for undisturbed sleep.
5.3. Timer Function
The programmable timer allows you to set the unit to turn on or off automatically within a 24-hour period. This feature helps conserve energy and ensures comfort when needed.
Video 5.1: A demonstration of the Avalla S-80 Air Conditioner's features, including its various modes and controls.
6. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your Avalla S-80 air conditioner.
6.1. Cleaning the Air Filter
The unit is equipped with a washable air filter. Clean the filter every two weeks or more frequently if the unit is used in a dusty environment.
- Unplug the air conditioner from the power outlet.
- Locate and remove the air filter from the back of the unit.
- Wash the filter under running water (warm, soapy water if heavily soiled).
- Allow the filter to air dry completely before reinserting it into the unit. Do not expose to direct sunlight.

Image 6.1: The air conditioner's dehumidifier function can assist in drying clothes, showcasing its versatility beyond cooling.
6.2. Draining Water
In dehumidifier mode or high humidity conditions, the internal water tank may fill. The unit will typically stop operating and indicate when the tank needs draining. Refer to the unit's specific draining port location (usually at the bottom rear) and follow the instructions to empty the water.
6.3. Storage
Before storing the unit for an extended period:
- Ensure the water tank is completely drained.
- Clean the air filter.
- Unplug the power cord and coil it neatly.
- Store the unit in a cool, dry place, away from direct sunlight and extreme temperatures.
7. Troubleshooting Guide
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power, power cord unplugged, full water tank. | Check power connection, empty water tank. |
| Unit does not cool effectively. | Air filter dirty, room too large, windows/doors open, exhaust hose not properly installed. | Clean air filter, ensure room size is within specifications, close windows/doors, check exhaust hose connection. |
| Unit is noisy. | Unit not on a level surface, air filter dirty, internal components vibrating. | Place on a level surface, clean air filter. If noise persists, contact support. |
| Water leakage. | Drain plug not properly sealed, unit tilted. | Ensure drain plug is secure, place unit on a level surface. |
8. Technical Specifications
| Feature | Specification |
|---|---|
| Model | AVS-80 |
| Cooling Capacity | 5000 BTU |
| Recommended Room Size | Up to 34m³ |
| Airflow Volume | 290m³/h |
| Dehumidification Capacity | 12 Litres/day |
| Noise Level | 50 dB |
| Energy Efficiency Rating | Class A |
| Power Consumption (Cooling) | 557W |
| Refrigerant | R-290 (Eco-friendly) |
| Voltage | 230 Volts |
| Dimensions (H x W x D) | 70 x 31 x 31.5 cm |
| Weight | 18.9 kg |
9. Warranty and Support
The Avalla S-80 Portable Air Conditioner comes with a 2-year warranty from the date of purchase. This warranty covers manufacturing defects and ensures peace of mind with your new appliance.
For technical support, troubleshooting assistance beyond this guide, or warranty claims, please contact Avalla customer support. You can find contact information on the official Avalla website or through your retailer.
For more information and to explore other Avalla products, visit the Avalla Store.