TrolMaster LMA-12

TrolMaster LMA-12 Lighting Control Adapter D User Manual

Model: LMA-12

Brand: TrolMaster

Introduction

The TrolMaster LMA-12 Lighting Control Adapter D is designed to integrate specific lighting fixtures, such as Dimlux Ballasts, with the TrolMaster Hydro-X control system. This adapter allows the Hydro-X system to manage and automate lighting schedules and intensity for compatible horticultural lighting equipment, enhancing control over your growing environment.

Product Overview

Key Features

  • Enables Hydro-X system control over Dimlux Ballasts.
  • Simple plug-and-play integration.
  • Robust design suitable for horticultural environments.

Components

The LMA-12 adapter typically includes the main adapter unit and an integrated RJ12 cable for connection to the control system.

TrolMaster LMA-12 Lighting Control Adapter D with RJ12 cable

Image: The TrolMaster LMA-12 Lighting Control Adapter D, showing the main unit and its attached RJ12 cable. This adapter facilitates communication between the Hydro-X controller and compatible lighting ballasts.

Setup Instructions

Follow these steps to properly set up your LMA-12 Lighting Control Adapter D:

  1. Identify Components: Ensure you have the TrolMaster Hydro-X controller, the LMA-12 adapter, and your Dimlux Ballast(s).
  2. Connect LMA-12 to Hydro-X: Plug the RJ12 cable from the LMA-12 adapter into an available control port on your TrolMaster Hydro-X controller.
  3. Connect LMA-12 to Ballast: Connect the other end of the LMA-12 adapter (or a splitter, if controlling multiple ballasts) to the control port of your Dimlux Ballast.
  4. Power On: Ensure all devices are properly connected and then power on your Hydro-X controller and lighting system.
  5. Configuration: Refer to your Hydro-X controller's manual for specific steps on how to detect and configure the connected lighting fixtures within the system settings.
Connection diagram for TrolMaster LMA-12 adapter

Image: A diagram illustrating the connection sequence: 1. Controller (Hydro-X), 2. Lighting Control Adapter (LMA-12), 3. Splitter (optional), and 4. G Ballast (Dimlux Ballast). This shows how the LMA-12 integrates into the lighting control system.

Operating Instructions

Once the LMA-12 adapter is connected and recognized by your Hydro-X controller, you can manage your Dimlux Ballasts through the Hydro-X interface.

  • Scheduling: Use the Hydro-X controller to set daily lighting schedules, including ON/OFF times.
  • Dimming: Adjust the light intensity (dimming) of your connected ballasts directly from the Hydro-X controller.
  • Automation: Configure advanced automation rules based on environmental conditions monitored by your Hydro-X system.

For detailed operation of the Hydro-X controller, please consult its dedicated user manual.

Maintenance

The LMA-12 adapter requires minimal maintenance to ensure optimal performance.

  • Cleaning: Periodically wipe the adapter with a dry, soft cloth to remove dust. Do not use liquid cleaners directly on the unit.
  • Inspection: Regularly check the RJ12 cable and connectors for any signs of wear or damage. Ensure connections are secure.
  • Environment: Operate the adapter within recommended environmental conditions (temperature, humidity) to ensure longevity.

Troubleshooting

Adapter Not Detected by Hydro-X

  • Check Connections: Ensure the RJ12 cable is securely plugged into both the LMA-12 and the Hydro-X controller.
  • Cable Integrity: Inspect the RJ12 cable for any visible damage. Try a different RJ12 cable if available.
  • Hydro-X Port: Try connecting the LMA-12 to a different control port on the Hydro-X controller.
  • Restart System: Power cycle the Hydro-X controller and the connected lighting system.

Lighting Fixture Not Responding

  • Ballast Connection: Verify the connection between the LMA-12 (or splitter) and the Dimlux Ballast.
  • Ballast Power: Ensure the Dimlux Ballast is powered on and functioning correctly independently of the control system.
  • Hydro-X Settings: Confirm that the lighting fixture is correctly configured and enabled within the Hydro-X controller's settings.
  • Compatibility: Ensure your specific Dimlux Ballast model is compatible with the LMA-12 adapter.

Specifications

FeatureDetail
Model NumberLMA-12
ManufacturerTrolMaster
Part NumberLMA-12
Product Dimensions5.12 x 7.36 x 3.47 inches
Item Weight1 pounds
ColorBlack
Included ComponentsModule
Batteries Required?No

Warranty Information

TrolMaster products are typically covered by a manufacturer's warranty. For specific details regarding the warranty period and terms for your LMA-12 adapter, please refer to the warranty card included with your product or visit the official TrolMaster website. Keep your proof of purchase for any warranty claims.

Support

If you encounter issues not covered in this manual or require further assistance, please contact TrolMaster customer support.

  • Online Resources: Visit the official TrolMaster website for FAQs, additional documentation, and software updates.
  • Contact Support: Refer to the contact information provided on the TrolMaster website or in your product packaging for direct support.

When contacting support, please have your product model (LMA-12) and purchase information ready to expedite assistance.

Related Documents - LMA-12

Preview Trolmaster Controller with VertX 600 Series Installation Guide for Commercial Grow Spaces
Step-by-step instructions for installing the Trolmaster Hydro-X Environment Control System (HCS-1) with the VertX 600 Series lighting system for commercial grow spaces, including necessary accessories like LMA-14 and ECS-5 connectors.
Preview TrolMaster Hydro-X Pro HCS-2: Advanced Horticultural Environmental Control System
Explore the TrolMaster Hydro-X Pro HCS-2, an advanced horticultural environmental control system featuring a 10.1-inch touchscreen, extensive module compatibility, and remote web-based control for optimized plant growth.
Preview TrolMaster TWS-1 Wireless Station: User Guide and Specifications
Comprehensive guide to the TrolMaster TWS-1 Wireless Station, covering installation, operation, pairing with the Hydro-X Pro controller, specifications, and regulatory information.
Preview TrolMaster TC-1 Grow Camera: Surveillance, Features, and Setup Guide
Comprehensive guide to the TrolMaster TC-1 Grow Camera, detailing its features for 24-7 grow room monitoring, plant-safe night vision, TM+ app integration, video recording, specifications, and setup instructions.
Preview TrolMaster DSR-1 25A Relay Device Station - Technical Specifications and Connection Guide
Detailed information on the TrolMaster DSR-1 25A Relay Device Station, including specifications, LED status indicators, and connection diagrams for horticultural control systems.
Preview TrolMaster TC-1 Grow Camera: User Guide and Specifications
Detailed overview, features, instructions, and specifications for the TrolMaster TC-1 Grow Camera, a high-quality surveillance camera for grow rooms. Learn about setup, internet access, mobile app usage, video recording, and FCC compliance.