1. Product Overview
The SYNLETT Wireless Call Reset Button (Model F007A) is designed to provide a convenient and efficient way for caregivers or service staff to remotely clear and reset calls within a wireless nurse call system. This device enhances operational efficiency by allowing staff to manage call alerts with a simple push, eliminating the need to physically interact with the central monitoring unit for each call clearance. It is an essential component for optimizing response times in various care and service environments.

Image 1.1: The SYNLETT Wireless Call Reset Button, showing the main unit, included lanyard, and wall-mount bracket.
2. Package Contents
Verify that all items listed below are present in your package:
- 1 x Clear Call Button (Reset Button)
- 1 x Battery (12V 23A)
- 1 x Call Button Mounting Bracket
- 1 x Lanyard Strap
- 1 x Double-Sided Adhesive Tape
- Screws for mounting

Image 2.1: All components included in the package, illustrating the button, battery, lanyard, mounting bracket, adhesive tape, and screws.
3. Setup and Installation
3.1. Battery Installation
- Gently pry open the back cover of the Clear Call Button.
- Insert the provided 12V 23A battery into the battery compartment, ensuring correct polarity (+/-).
- Close the back cover securely.
3.2. Mounting Options
The Clear Call Button offers versatile mounting options to suit various environments:
- Wall Mounting: Use the provided mounting bracket and screws to fix the button to a wall, such as at a bedside or in a bathroom.
- Adhesive Mounting: Attach the mounting bracket to most smooth and clean surfaces using the supplied double-sided adhesive tape.
- Portable Use: Attach the button to the included lanyard strap to wear it around the neck for mobile use.

Image 3.1: The Clear Call Button securely placed within its mounting bracket, ready for wall or adhesive attachment.
4. Operating Instructions
4.1. Pairing with Central Monitoring Unit (CMU)
The SYNLETT Wireless Call Reset Button MUST be programmed and paired with a compatible SYNLETT central monitoring unit (CMU), such as the SYNLETT Q034G, before it can function properly. Refer to your CMU's instruction manual for detailed pairing procedures. This button does not program to a specific channel number but acts as a universal clear/reset signal for the paired CMU.

Image 4.1: An overview of the SYNLETT wireless call system, illustrating how various components, including the Clear Call Button, connect to the Central Monitoring Unit (CMU).
4.2. Clearing Calls
Once paired, simply press the "CLEAR" button on the device to remotely reset and clear all active calls on the connected SYNLETT central monitoring unit. This action will silence alarms and clear the display, indicating that the calls have been acknowledged and addressed.

Image 4.2: A caregiver demonstrating the use of the Clear Call Button to remotely clear calls, highlighting its convenience in a care setting.
5. Applications
The SYNLETT Wireless Call Reset Button is suitable for a wide range of professional and personal environments where efficient call management is crucial:
- Restaurants and Cafes
- Clinics and Hospitals (Nurses Stations, Emergency Rooms, Treatment Rooms)
- Care Facilities (Retirement Homes, Elderly Care, Long-Term Care Facilities)
- Home Service and Personal Care
- Offices and Call Desks
- Churches and other public venues
6. Maintenance
To ensure the longevity and optimal performance of your SYNLETT Wireless Call Reset Button, follow these maintenance guidelines:
- Cleaning: Wipe the device regularly with a soft, dry cloth. For stubborn dirt, a slightly damp cloth can be used. Avoid abrasive cleaners or solvents.
- Battery Replacement: Replace the 12V 23A battery when the device's indicator light (if present) signals low power, or if the button becomes unresponsive.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures when not in use for extended periods.
- Avoid Impact: Protect the device from drops and impacts, which can damage internal components.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Button does not clear calls. |
|
|
| Button indicator light not working. |
|
|
| Difficulty prying open for battery. | Tight casing. | Use a small, flat tool (e.g., a thin screwdriver) to gently pry open the casing from the designated notch. Apply even pressure to avoid damage. |
8. Specifications
| Feature | Detail |
|---|---|
| Model Number | F007A |
| Brand | SYNLETT |
| Control Method | Touch |
| Mounting Type | Wall Mount |
| Power Source | Battery Powered |
| Battery Type | 1 x 12V 23A (included) |
| Voltage | 12 Volts |
| Product Dimensions | 2.83 x 2.83 x 1.42 inches |
| Item Weight | 1.94 ounces |
| Color | White |
| UPC | 768494045968 |
9. Warranty and Support
For warranty information, technical support, or any inquiries regarding your SYNLETT Wireless Call Reset Button, please contact SYNLETT customer service. Refer to the product packaging or the official SYNLETT website for the most current contact details and warranty terms.