1. Introduction
This manual provides instructions for the Renogy Suntree 32 Amp Single-Pole DC Circuit Breaker. This device is designed to protect DC electrical installations against overloads and short circuits. It incorporates both thermal and magnetic tripping mechanisms to ensure reliability and safety. The circuit breaker automatically disconnects the electrical circuit upon fault detection, preventing wire damage and fire hazards. It can also be manually operated for system maintenance. Its reversible connection design allows for wiring in either direction, supporting bidirectional current flow. A built-in indicator window provides immediate visual confirmation of the circuit breaker's contact position. The buckle design facilitates easy installation on standard DIN rails.

Figure 1: Renogy Suntree 32 Amp Single-Pole DC Circuit Breaker. This image shows the front and side view of the circuit breaker with its green toggle switch.
2. Safety Instructions
Please read and understand all safety instructions before installing or operating the circuit breaker. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Installation and maintenance should only be performed by qualified personnel.
- Always disconnect power to the circuit before installing, servicing, or removing the circuit breaker.
- Ensure the circuit breaker's current rating matches the circuit requirements.
- Do not use the circuit breaker in environments exceeding its specified operating conditions (temperature, humidity).
- Verify all connections are secure and properly insulated to prevent short circuits.
- Do not bypass or tamper with the circuit breaker's protective mechanisms.
- Wear appropriate personal protective equipment (PPE), including insulated gloves and eye protection, during installation and maintenance.
3. Product Features
- Overload and Short Circuit Protection: Equipped with both thermal and magnetic tripping mechanisms.
- Manual Disconnection: Can be manually opened under full rated load for maintenance.
- Reversible Connection: Allows wiring in either direction for bidirectional current flow.
- Contact Position Indicator: Built-in window clearly shows ON/OFF status.
- DIN Rail Mount: Buckle design for easy installation on standard DIN rails.
- Durable Construction: Designed for long mechanical and electrical life.

Figure 2: Internal components of the circuit breaker, illustrating the thermal and magnetic tripping mechanisms for reliable and safe operation.

Figure 3: Durability specifications for the circuit breaker, highlighting a mechanical life of 20,000 operations and an electrical life of 10,000 operations, along with high electrical conductivity.
4. Specifications
| Attribute | Value |
|---|---|
| Brand | Renogy |
| Model Number | SUNDCCB32MN1P |
| Current Rating | 32 Amps |
| Circuit Breaker Type | Standard |
| Mounting Type | DIN Rail Mount |
| Number Of Poles | 1 |
| Material | Copper |
| Item Weight | 3.84 ounces |
| Product Dimensions | 3.2 x 3 x 0.7 inches |
| UPC | 810009719663 |

Figure 4: Physical dimensions of the Renogy Suntree 32 Amp Single-Pole DC Circuit Breaker, showing a length of 3.2 inches, a width of 0.7 inches, and a height of 3.2 inches, with a weight of 4.2 ounces.

Figure 5: Guidelines for selecting the correct circuit breaker size for controllers, inverters, DC devices, and solar panels. It outlines calculations based on continuous operating current and short-circuit current.
5. Installation
5.1 Mounting on DIN Rail
- Ensure the DIN rail is securely mounted within the breaker box or enclosure.
- Align the circuit breaker's top slot with the top edge of the DIN rail.
- Press the circuit breaker firmly against the DIN rail until the buckle mechanism clicks into place, securing it.
- Verify the circuit breaker is firmly attached and does not wobble.

Figure 6: Step-by-step diagram illustrating the quick installation process of the circuit breaker onto a standard DIN rail using its buckle design. The diagram shows aligning the slot, pressing, and securing with a click.
5.2 Wiring Connections
The Renogy Suntree DC Circuit Breaker is designed for reversible connection, meaning it can be wired in either direction. However, it is crucial to maintain correct polarity for DC systems.
- Identify the positive (+) and negative (-) terminals on the circuit breaker and your DC system components.
- Connect the positive wire from the power source (e.g., solar panel, battery) to one terminal of the circuit breaker.
- Connect the positive wire to the load (e.g., inverter, charge controller) from the other terminal of the circuit breaker.
- Ensure all wire connections are tight and secure to prevent loose contacts and potential arcing.
- Double-check all wiring for correct polarity before applying power.

Figure 7: Diagram showing the connection points for the circuit breaker, indicating the positive terminal at the top and the corresponding connection at the bottom. This illustrates the reversible connection capability.
6. Operation
6.1 Switching On/Off
- To switch the circuit breaker ON, push the toggle switch upwards until it locks into the "ON" position. The indicator window will show green.
- To switch the circuit breaker OFF, pull the toggle switch downwards until it locks into the "OFF" position. The indicator window will show red.
6.2 Automatic Tripping
In the event of an overload or short circuit, the circuit breaker will automatically trip to the "OFF" position, interrupting the circuit and protecting connected equipment. The indicator window will show red.
6.3 Resetting the Circuit Breaker
After an automatic trip, identify and resolve the cause of the fault (e.g., remove overload, fix short circuit) before attempting to reset the breaker. Once the fault is cleared, push the toggle switch downwards to fully reset it, then push it upwards to the "ON" position.

Figure 8: Visual representation of the circuit breaker's indicator window, showing green for "ON" status and red for "OFF" status, providing clear operational feedback.
7. Maintenance
The Renogy Suntree DC Circuit Breaker requires minimal maintenance. Regular inspections are recommended to ensure optimal performance and safety.
- Periodic Visual Inspection: Regularly check the circuit breaker for any signs of physical damage, discoloration, or loose connections.
- Cleaning: If necessary, gently clean the exterior of the circuit breaker with a dry, soft cloth. Do not use abrasive cleaners or solvents.
- Functionality Test: Periodically test the manual switching mechanism by turning the breaker OFF and ON.
- Connection Check: Ensure all terminal connections remain tight. Loose connections can lead to overheating and potential hazards.
Note: Do not attempt to open or repair the circuit breaker. Refer to qualified personnel for any issues beyond basic inspection and cleaning.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Circuit breaker trips frequently. | Overload on the circuit, short circuit, or faulty appliance. | Reduce the load on the circuit. Inspect wiring and connected devices for short circuits. Disconnect faulty appliances. |
| Circuit breaker does not reset. | Persistent fault (overload/short circuit) or internal damage to the breaker. | Ensure the fault is completely cleared. If the fault is cleared and it still doesn't reset, the breaker may be damaged and require replacement. |
| Circuit breaker feels hot. | Overload, loose connections, or undersized wiring. | Check for overloads. Tighten all terminal connections. Verify wire gauge is appropriate for the current. |
| No power to the circuit, but breaker is ON. | Faulty wiring upstream/downstream, or internal breaker failure. | Check continuity of wiring. If wiring is intact, the breaker may be faulty and require replacement. |
9. Warranty and Support
Renogy products are manufactured with high-quality materials and craftsmanship. For specific warranty information, please refer to the warranty card included with your product or visit the official Renogy website. For technical support, product inquiries, or assistance with troubleshooting, please contact Renogy customer service through their official channels.