1. Important Safety Instructions
Please read all instructions and cautionary markings on the unit and all appropriate sections of this manual carefully before installation and operation. This manual contains important instructions for the Y&H VM PLUS-5.5KW-M100A Hybrid Solar Inverter that must be followed during installation and maintenance.
- Installation must be performed by qualified personnel.
- Ensure all wiring is correctly connected and securely fastened to prevent electrical hazards.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Disconnect all power sources (PV, battery, utility) before performing any maintenance or wiring.
- Wear appropriate personal protective equipment (PPE) during installation and maintenance.
- This inverter is designed for indoor use. Avoid exposure to rain, snow, or excessive moisture.
2. Product Overview
The Y&H VM PLUS-5.5KW-M100A is a 5500W hybrid solar inverter with an integrated MPPT 100A solar charge controller. It features a 500VDC PV input, 220VAC output, and operates on a 48VDC battery system, providing a pure sine wave output. It also includes WiFi communication capabilities for monitoring.
Figure 2.1: Front, side, and bottom views of the Y&H Hybrid Solar Inverter with labeled components.
- LDC display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons
- Power on/off switch
- AC input
- AC output
- PV input
- Battery input
- Circuit breaker
- USB communication port
- RS-232 communication port
Figure 2.2: Overview of key features including frequency range, battery voltage, max output power, waveform, output voltage, parallel support (non-available), solar charge current, AC charge current, and all-around protection.
Figure 2.3: Various views of the Y&H 5.5KW Hybrid Solar Inverter.
3. Installation
3.1 System Connection Diagram
Figure 3.1: This diagram illustrates how the inverter integrates with solar panels, a generator, the utility grid, battery packs, and various home appliances.
The inverter can draw power from solar panels, a generator, or the utility grid to charge battery packs and supply power to home appliances. It is designed to manage these power sources efficiently.
3.2 PV Connection
Figure 3.2: Detailed PV connection diagram showing solar panel input to the inverter and a table for PV module selection guidelines.
CAUTION: Before connecting to an AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and is protected from overcurrent. The recommended AC breaker specification is 32A for 3.5KW models and 50A for 5.5KW models.
CAUTION: There are two terminal blocks with "IN" and "OUT" markings. Do not mis-connect input and output connectors.
WARNING: All wiring must be performed by a qualified personnel.
WARNING: It is critical for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, use the proper recommended cable size as specified below.
Suggested Cable Requirement for AC Wires
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 3.5KW | 12 AWG | 4 | 1.2 Nm |
| 5.5KW | 10 AWG | 6 | 1.2 Nm |
3.3 PV Module Selection
When selecting PV modules, consider the following parameters:
- Open circuit Voltage (Voc) of PV modules should not exceed the maximum PV array open circuit voltage of the inverter (500Vdc).
- Open circuit Voltage (Voc) of PV modules should be higher than the minimum battery voltage (48VDC).
| INVERTER MODEL | 3.5KW | 5.5KW | |
|---|---|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc | 500Vdc | |
| PV Array MPPT Voltage Range | 120Vdc~450Vdc | 120Vdc~450Vdc | |
Example: For a 250W PV module, recommended configurations are:
| Solar Panel Spec. (reference) | SOLAR INPUT | Q'ty of panels | Total input power |
|---|---|---|---|
| - 250Wp - Vmp: 30.1Vdc - Imp: 8.3A - Voc: 37.7Vdc - Isc: 8.4A - Cells: 60 |
Min in serial: 6 pcs, max. in serial: 13 pcs | ||
| 6 pcs in serial | 6 pcs | 1500W | |
| 8 pcs in serial | 8 pcs | 2000W | |
| 12 pcs in serial | 12 pcs | 3000W | |
| 13 pcs in serial | 13 pcs | 3250W | |
| 8 pieces in serial and 2 sets in parallel | 16 pcs | 4000W | |
| 10 pieces in serial and 2 sets in parallel | 20 pcs | 5000W |
3.4 General Connection Diagram
Figure 3.3: General connection diagram. This inverter does not support multiple units working in parallel.
This diagram illustrates the primary connections for the inverter. It shows the PV input (solar panels connected in series), generator or utility grid AC input, 48V battery connection (supporting SLD, AGM, Lithium-ion, FLD, and user custom batteries), and the AC output to home appliances. Note that this inverter is designed for single-unit operation and does not support parallel or stacked configurations.
4. Operating Instructions
4.1 LCD Display and Function Keys
Figure 4.1: Front panel showing the LCD display, LED indicators, and function keys for inverter control and monitoring.
LED Indicator Messages
| LED Indicator | Messages | |
|---|---|---|
| AC / INV | Green Solid On | Output is powered by utility in Line mode. |
| Green Flashing | Output is powered by battery or PV in battery mode. | |
| CHG | Green Solid On | Battery is fully charged. |
| Green Flashing | Battery is charging. | |
| FAULT | Red Solid On | Fault occurs in the inverter. |
| Red Flashing | Warning condition occurs in the inverter. |
Function Keys
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.2 Working Modes
Figure 4.2: Overview of the inverter's charging and load output modes.
4.2.1 Charging Modes (4 Modes to Charge Battery Bank)
- Solar First: Solar energy will charge the battery as the primary priority. Utility power will only charge the battery if solar energy is not available.
- Utility First: Utility power will charge the battery as the primary priority. Solar energy will only charge the battery when utility power is not available.
- Solar and Utility: Both solar energy and utility power will charge the battery simultaneously.
- Only Solar: Solar energy will be the only charge source, regardless of utility power availability.
4.2.2 Load Output Working Modes (3 Modes to Power Loads)
- Solar First (PV Priority): PV power loads first, then Utility.
- Utility First (Default): Utility as first to power load.
- Inverter Mode: Battery power loads first, utility power loads when battery low voltage.
4.3 Operation with and without Battery Connected
Figure 4.3: Power flow diagrams for inverter operation, distinguishing between systems with and without external battery packs.
The inverter can operate in configurations both with and without external battery packs. The diagrams above illustrate the power flow from solar, generator, or utility to home appliances under these different scenarios. When batteries are connected, they can store excess energy and provide power during outages or when other sources are unavailable. Without batteries, the inverter acts as a direct power manager between sources and loads.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your Y&H Hybrid Solar Inverter.
- Cleaning: Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and prevent overheating. Use a soft, dry cloth for cleaning the exterior.
- Connections: Periodically check all electrical connections (PV, battery, AC input/output) for tightness and corrosion. Loose connections can lead to power loss or overheating.
- Environment: Ensure the inverter is installed in a cool, dry, and well-ventilated area, away from direct sunlight, heat sources, and flammable materials.
- Battery Health: If using lead-acid batteries, regularly check their water levels (if applicable) and ensure terminals are clean and free of corrosion. Follow battery manufacturer's maintenance guidelines.
- Firmware: Check the manufacturer's website for any available firmware updates to ensure your inverter has the latest features and bug fixes.
6. Troubleshooting
This section provides basic troubleshooting steps for common issues. For more complex problems, contact technical support.
- No Power Output:
- Check if the inverter is turned on.
- Verify battery connections and voltage.
- Check AC input and output circuit breakers.
- Ensure PV input is sufficient if operating in solar-priority modes.
- Fault Indicator On:
- Refer to the LED Indicator Messages table (Figure 4.1) for the specific fault code or flashing pattern.
- Common faults include overload, short circuit, over-temperature, or battery issues.
- Disconnect loads, allow cooling, or check battery health as appropriate.
- Battery Not Charging:
- Check PV panel connections and ensure sufficient sunlight.
- Verify AC input connection if charging from utility/generator.
- Check battery settings on the inverter display.
7. Specifications
Key technical specifications for the Y&H VM PLUS-5.5KW-M100A Hybrid Solar Inverter:
| Feature | Specification |
|---|---|
| Brand | Y&H |
| Model Number | VM PLUS-5.5KW-M100A |
| Output Power | 5500 watts |
| Input Voltage | 48 volts (DC) |
| Output Voltage | 230 volts (AC) |
| Max. PV Array Open Circuit Voltage | 500Vdc |
| PV Array MPPT Voltage Range | 120Vdc~450Vdc |
| Max Charge Current (Solar) | 100A |
| Max Charge Current (AC) | 80A |
| Wave Form | Pure Sine Wave |
| Parallel Support | No |
| Communication | WiFi, USB, RS-232 |
| UPC | 746608714474 |
8. Warranty and Support
For warranty information, please refer to the documentation included with your purchase or visit the official Y&H website. Technical support can be reached through the contact information provided by your retailer or on the Y&H support portal.
Always provide your model number (VM PLUS-5.5KW-M100A) and purchase date when contacting support for efficient service.