Maxxima MEW-OS175W
Maxxima Wall Mount PIR Occupancy Sensor User Manual
Model: MEW-OS175W
1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your Maxxima Wall Mount PIR Occupancy Sensor. Please read this manual thoroughly before installation and use to ensure proper function and safety.
The Maxxima Wall Mount PIR Occupancy Sensor utilizes passive infrared (PIR) technology to detect movement, automatically controlling lights or fans based on room occupancy. It is designed for 120V residential applications in areas such as entryways, hallways, closets, storage areas, attics, utility rooms, and garages.
2. Product Features
- 180-degree detection angle with an adjustable coverage range from 6.5 ft. to 26 ft. when mounted at a height of 8.5 ft. Automatically turns lights on/off.
- Adjustable delayed off setting ranging from 18 seconds to 10 minutes. The light will automatically shut off if no motion is detected after the set time.
- Maximum load incandescent: 1000W@120V, 150W Max Load LED, 1/4 HP. No minimum load required.
- Compatible with LED, Incandescent, Electronic Ballast Fluorescent, Compact-fluorescent (CFL), Magnetic Low-Voltage (MLV), and Electronic Low-Voltage (ELV) lighting types.
- Features adjustable sensitivity and an ambient light sensor.
- Operating temperature range: -23°F to 104°F (-30.5°C to 40°C).
- ETL Listed.
- Neutral wire required for installation.
3. Product Overview
Familiarize yourself with the components and appearance of your Maxxima Wall Mount PIR Occupancy Sensor.
Figure 3.1: Front view of the sensor, showing the main body and adjustable PIR lens.
Figure 3.2: Back view of the sensor, highlighting the mounting plate.
Figure 3.3: Side view of the sensor, showing its profile.
Figure 3.4: Alternative side view of the sensor.
Figure 3.5: Top view of the sensor.
Figure 3.6: Example of the sensor installed high in a room corner, providing wide coverage.
Product Video
Video 3.1: An overview of the Maxxima Wall Mount PIR Occupancy Sensor, demonstrating its features and typical installation scenarios.
4. Specifications
Figure 4.1: Detailed dimensions of the sensor for installation planning.
| Attribute | Value |
|---|---|
| Brand | Maxxima |
| Model Number | MEW-OS175W |
| Color | White |
| Power Source | Corded Electric |
| Item Weight | 5.1 ounces (0.32 Pounds) |
| Maximum Range | 26 Feet |
| Mounting Type | Wall Mount |
| Compatible Devices | Light, Fan |
| Upper Temperature Rating | 38 Degrees Celsius (100.4°F) |
| UPC | 755183182189 |
| Product Dimensions | 8 x 2.5 x 1.8 inches |
| Date First Available | October 12, 2021 |
5. Setup & Installation
All necessary hardware and detailed instructions are included for easy installation. A neutral wire is required for proper operation.
Wiring Diagram
For detailed wiring instructions, please refer to the diagram included in the physical instruction manual provided with your sensor. It is recommended that installation be performed by a qualified electrician to ensure safety and compliance with local electrical codes.
6. Operating Instructions
The sensor features adjustable settings for sensitivity, time delay, and ambient light. These settings can be customized using the dials located on the bottom of the unit.
Figure 6.1: Location of the adjustable dials for Sensitivity, Time Delay, and Ambient Light.
Adjusting Settings
- Sensitivity (SENS): Adjusts the detection range of the PIR sensor. Turn the dial to increase or decrease the sensitivity to motion.
- Time Delay (TIME): Sets the duration the connected load remains on after the last detected motion. Adjustable from 18 seconds to 10 minutes.
- Ambient Light (LUX): Determines the ambient light level at which the sensor will activate. This allows the sensor to only turn on lights when the room is dark enough.
To access these dials, you may need to remove the included cover plate.
7. Maintenance
To ensure optimal performance, keep the sensor lens clean and free from dust or obstructions. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents, as these may damage the sensor's components.
8. Troubleshooting
Common Issues and Solutions
- Lights not turning on: Check power connection, ensure sensor is not obstructed, verify ambient light setting is appropriate for current light conditions, and adjust sensitivity.
- Lights staying on too long/short: Adjust the Time Delay setting.
- False triggers: Reduce sensitivity. Ensure the sensor is not exposed to direct heat sources, air drafts, or rapid temperature changes, which can cause unintended activation.
9. Warranty & Support
This Maxxima Wall Mount PIR Occupancy Sensor is backed by a 1-year warranty. For technical support or warranty claims, please contact Maxxima customer service.
For more information, visit the Maxxima Store on Amazon.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.