ACEIRMC Time Delay Relay User Manual
Model: DC 5V 12V 24V Delay Controller Board
Introduction
This manual provides comprehensive instructions for the setup, operation, and maintenance of your ACEIRMC Time Delay Relay module. This versatile module features an LCD display, wide voltage compatibility (DC 6-30V, with Micro USB 5V support), and a broad timing range (0.01s to 9999 minutes). It is designed for various applications including smart home automation, industrial control, and protection equipment.
Safety Information
Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in electric shock, fire, or damage to the product.
- Ensure the power supply voltage is within the specified range (DC 6-30V or Micro USB 5V).
- Do not exceed the maximum switching current of 10 Amps.
- Always disconnect power before making any wiring connections or adjustments.
- Avoid contact with live circuits.
- Install the module in a dry, well-ventilated area, away from direct sunlight, high temperatures, and corrosive environments.
- This product is intended for use by individuals familiar with electronic components and wiring.
Product Overview
The ACEIRMC Time Delay Relay module is equipped with an LCD display for clear parameter viewing, control buttons for easy programming, and robust terminal blocks for secure connections.

Figure 1: Two ACEIRMC Time Delay Relay modules. Each module features an LCD screen, control buttons, a relay, and terminal blocks for power and output connections. The modules are shown with clear suction cup feet for mounting.

Figure 2: Top and bottom views of the relay module. The top view shows the LCD, buttons (SET, UP, DOWN, STOP), relay, and terminal blocks. The bottom view reveals the main control chip and other surface-mounted components.

Figure 3: Detailed close-ups of key components. This includes the relay, the micro USB power input, and the terminal blocks for input power (DC 6-30V) and relay output (NO, NC, COM).
Key Components:
- LCD Display: Shows current mode, timing parameters (OP, CL, LOP), and status.
- Control Buttons:
- SET: Enters/exits parameter setting mode, confirms selection.
- UP/DOWN: Adjusts parameter values, navigates menus.
- STOP: Stops the current operation, enables/disables relay output.
- Power Input Terminals: DC 6-30V.
- Micro USB Port: Alternative 5V power supply.
- Relay Output Terminals: Normally Open (NO), Normally Closed (NC), Common (COM).
- Trigger Input: High level trigger (3.0V-34V) and low level trigger (0V-0.2V).
Setup
Before connecting the module, ensure all power sources are disconnected.
- Power Connection:
- For DC 6-30V power, connect the positive (+) and negative (-) wires to the corresponding input terminals on the module.
- Alternatively, for 5V power, connect a Micro USB cable to the Micro USB port.
- Load Connection:
- Connect your load (e.g., light, motor) to the relay output terminals (NO, NC, COM) based on your application's requirements.
- Normally Open (NO): The circuit is open when the relay is de-energized and closes when energized.
- Normally Closed (NC): The circuit is closed when the relay is de-energized and opens when energized.
- Common (COM): The common terminal for the relay switch.
- Connect your load (e.g., light, motor) to the relay output terminals (NO, NC, COM) based on your application's requirements.
- Trigger Connection (Optional):
- If using an external trigger, connect the trigger signal to the designated trigger input terminal. The module supports both high-level (3.0V-34V) and low-level (0V-0.2V) triggers.

Figure 4: A single relay module showing the layout of the LCD, buttons, and terminal blocks, which are crucial for proper wiring during setup.
Operating Instructions
The module supports various operating modes and programmable parameters.
Parameter Settings:
Press the SET button to enter parameter setting mode. The LCD will display the current mode (e.g., P-1.1). Use UP/DOWN to navigate between modes and adjust values. Press SET again to confirm and move to the next parameter or exit.
- OP: Turn-on time (0.01s - 9999mins).
- CL: Turn-off time (0.01s - 9999mins).
- LOP: Number of cycles (1-9999, "---" for infinite loop).
All setting parameters are automatically saved upon power-off.
Operating Modes:
The module offers multiple operating modes (P-1.1 to P-4), each with specific functionalities. Refer to the LCD display for the current mode.
| Mode | Description | Parameters |
|---|---|---|
| P-1.1 | Trigger ON, then delay OP time, relay OFF. | OP |
| P-1.2 | Trigger ON, delay CL time, relay ON, then delay OP time, relay OFF. | OP, CL |
| P-1.3 | Trigger ON, delay OP time, relay OFF, then delay CL time, relay ON. Loop LOP times. | OP, CL, LOP |
| P-2 | Trigger ON, delay OP time, relay OFF. During delay, re-trigger resets timer. | OP |
| P-3.1 | Trigger ON, delay OP time, relay ON. During delay, re-trigger stops timer. | OP |
| P-3.2 | Trigger ON, delay OP time, relay OFF. During delay, re-trigger stops timer. | OP |
| P-4 | Signal holding mode. If trigger signal is present, relay is ON. If signal disappears, delay OP time, relay OFF. | OP |
STOP Button Functionality:
In the main interface, short press the STOP button to switch between ON and OFF states for the relay output. This function allows for immediate control of the connected load.
Maintenance
The ACEIRMC Time Delay Relay module requires minimal maintenance.
- Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning.
- Ensure all wiring connections remain secure. Periodically check for loose terminals.
- Avoid exposing the module to extreme temperatures, humidity, or corrosive substances.
- Do not attempt to disassemble the module beyond what is necessary for wiring.
Troubleshooting
If you encounter issues with your module, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Module does not power on. | Incorrect voltage, loose power connection, faulty power supply. | Verify input voltage (DC 6-30V or 5V Micro USB). Check power wiring for secure connections. Test power supply. |
| Relay does not switch. | Incorrect mode setting, incorrect trigger signal, faulty load connection, relay output disabled. | Check the selected operating mode and parameters. Ensure trigger signal is correct (high/low level). Verify load wiring. Press STOP button to enable relay output if it's disabled. |
| LCD display is blank or erratic. | Insufficient power, physical damage. | Ensure stable power supply. Inspect for visible damage. |
| Timing is inaccurate. | Incorrect parameter values (OP, CL). | Re-enter parameter setting mode and verify OP and CL values. |
Specifications
| Feature | Detail |
|---|---|
| Operating Voltage Range | DC 6-30V (main), Micro USB 5V (alternative) |
| Timing Range | 0.01 seconds to 9999 minutes (continuously adjustable) |
| Trigger Input | High Level (3.0V-34V), Low Level (0V-0.2V) |
| Relay Contact Material | Silver Alloy |
| Maximum Switching Current | 10 Amps |
| Maximum Switching Voltage | 30 Volts |
| Wattage | 1.5 watts |
| Mounting Type | Panel Mount |
| Dimensions | 5.79 x 4.13 x 1.02 inches (Package) |
| Item Weight | 2.39 ounces |
Warranty and Support
For warranty information and technical support, please contact ACEIRMC customer service through the retailer where the product was purchased or visit the official ACEIRMC store page on Amazon.