1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of the Copeland ZR36K3-TF5-230 Compliant Scroll Compressor. This compressor is designed for specific industrial applications and operates on 200-230V-AC power. Please read this manual thoroughly before attempting any installation, operation, or maintenance procedures.
2. Safety Information
WARNING: Service is exclusively for trained personnel only. Failure to observe safety warnings can result in severe injury or death. This compressor operates with high voltage and pressure. Always disconnect power before servicing.
- Ensure all electrical connections are made by a qualified electrician in accordance with local and national electrical codes.
- Wear appropriate personal protective equipment (PPE) including safety glasses and gloves.
- Do not operate the compressor if any parts are damaged or missing.
- Ensure proper ventilation in the installation area.
- Never exceed the specified operating pressures and temperatures.
Refer to the product label for specific warnings and electrical specifications.

Figure 2.1: Product label displaying model number ZR36K3-TF5-230 and serial number 99GR1244L, along with electrical ratings. This label provides critical safety and operational data.
3. Setup and Installation
Proper installation is crucial for the performance and longevity of the compressor. Ensure the mounting surface is level and capable of supporting the compressor's weight.

Figure 3.1: Front view of the Copeland ZR36K3-TF5-230 compressor, showing its overall dimensions and connection points.

Figure 3.2: Side view of the compressor, highlighting the refrigerant line connections and mounting feet.

Figure 3.3: Rear view of the compressor, showing the electrical terminal box and additional mounting details.

Figure 3.4: Close-up of the product tag, indicating the weight of the unit (58 lbs) and confirming the model ZR36K3-TF5-230, along with an identifier 854251.
3.1. Mounting
Secure the compressor using appropriate bolts through the mounting feet. Ensure there is adequate clearance for airflow and service access around the unit.
3.2. Electrical Connections
Connect the compressor to a 200-230V-AC, 3-phase power supply. Refer to the wiring diagram on the compressor's label and consult a qualified electrician for proper wiring. Ensure correct phase rotation for optimal performance.

Figure 3.5: Detail of the Copeland brand and "Compliant Scroll" designation on the compressor label, indicating the type of compressor technology.
3.3. Refrigerant Line Connections
Connect the suction and discharge lines according to standard HVAC practices. Ensure all connections are leak-free. Use appropriate brazing techniques if required.
4. Operating Instructions
Before starting the compressor, ensure all installation steps are complete and verified. Check refrigerant charge and oil levels as per system requirements.
4.1. Initial Startup
- Verify all electrical and refrigerant connections are secure.
- Ensure the system is properly evacuated and charged with the correct refrigerant type and amount.
- Apply power to the compressor. Monitor current draw and pressures during startup.
- Listen for unusual noises or vibrations.
4.2. Normal Operation
The compressor is designed for continuous operation within its specified envelope. Monitor system pressures, temperatures, and compressor current regularly to ensure efficient operation.
5. Maintenance
Regular maintenance extends the life of the compressor and ensures optimal performance. Always disconnect power before performing any maintenance.
- Annual Inspection: Check for refrigerant leaks, inspect electrical connections for tightness, and verify proper oil level.
- Cleaning: Keep the compressor and surrounding area clean and free of debris to ensure proper heat dissipation.
- Oil Analysis: Periodically perform oil analysis to check for contaminants and degradation, especially in critical applications.
6. Troubleshooting
This section provides guidance for common issues. For complex problems, consult a qualified HVAC technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Compressor not starting | No power, tripped breaker, faulty wiring, control issue | Check power supply, reset breaker, inspect wiring, check control circuit |
| Compressor running but no cooling | Low refrigerant charge, restricted lines, faulty expansion valve | Check refrigerant levels, inspect lines for blockages, test expansion valve |
| Excessive noise or vibration | Loose mounting, internal compressor issue, liquid slugging | Tighten mounting bolts, check for proper superheat, consult technician for internal issues |
7. Specifications
| Attribute | Value |
|---|---|
| Model Name | ZR36K3 TF5 230 |
| Brand | Copeland |
| Voltage | 230 Volts |
| Item Weight | 61.6 Pounds |
| Product Dimensions | 19 x 12.5 x 12.5 inches |
| Manufacturer | COPELAND |
| ASIN | B09HYNFGH1 |
| First Available | October 7, 2021 |
8. Warranty and Support
For warranty information and technical support, please contact Copeland customer service or your authorized distributor. Ensure you have your model number (ZR36K3-TF5-230) and serial number (99GR1244L) available when contacting support.
You can find general customer support information here.





