Kalecope Q60-US

Kalecope Shockwave Therapy Machine User Manual

Model: Q60-US

1. Introduction

The Kalecope Shockwave Therapy Machine is designed to promote healing, regeneration, and reparative processes in tendons and soft tissues. This non-surgical and non-invasive device is widely applied for various soft tissue treatments, offering efficient analgesia and rapid recovery from joint and muscle pain, including sports-induced injuries.

This manual provides essential information for the safe and effective use of your shockwave therapy machine. Please read it thoroughly before operation.

2. Safety Information

Important: Please review the following safety guidelines before using the device.

  • Individuals with heart disease and hypertension should avoid using this product.
  • Do not use if you have acute inflammation, deep venous thrombosis, goiter, asthma, or cancer.
  • Avoid use on areas with ruptured blood vessels or trauma with bleeding.
  • Pregnant women should not use this device.
  • Do not apply to areas with artificial fillings after cosmetic surgery or where metallic materials are present in the body.
  • Avoid use on inflamed skin or areas with body swelling.
  • Individuals with abnormal immune system function should not use this product.

3. Package Contents

Upon opening the package, ensure all the following components are present:

  • 1 × Shockwave therapy machine (Approximate size: 16in x 14.17in x 6.3in, 26 lbs)
  • 1 × Shockwave handle
  • 5 × Transmitters (working heads)
  • 3 × Bullets
  • 2 × Shockwave holders
Kalecope Shockwave Therapy Machine and its components

Image: The Kalecope Shockwave Therapy Machine with its main unit, handle, and five different working heads.

4. Setup

Follow these steps to set up your device for first use:

  1. Carefully unpack all components from the packaging.
  2. Connect the shockwave handle to the main machine unit. Ensure it is securely attached.
  3. Plug the power cord into the machine's power socket and then into a suitable electrical outlet (110V-220V).
  4. Turn on the machine using the power switch button located on the back.
Kalecope Shockwave Therapy Machine with handle and working heads connected

Image: The main unit of the shockwave therapy machine with the handle connected and various working heads displayed.

5. Operating Instructions

The Kalecope Shockwave Therapy Machine features a user-friendly HD touch screen for easy operation.

  1. Select Treatment Area: On the touch screen, select the appropriate setting for the specific part of the body you intend to treat. The screen will display suggested adjustment values.
  2. Attach Working Head: Select and attach the appropriate working head (transmitter) for the chosen treatment area. Five different working heads are provided for various applications.
  3. Apply Gel: Cleanse the skin of the area to be treated. Apply a thin layer of conductive gel (not included) to the treatment area. Do not use too much gel.
  4. Begin Treatment: Follow the on-screen prompts to initiate the shockwave therapy.
  5. Post-Treatment: After the session, wipe any residue from the skin with a hot towel and clean the working head with a warm towel.
Touch screen display of the Kalecope Shockwave Therapy Machine showing body parts for treatment selection

Image: The machine's touch screen interface, allowing selection of various body parts for targeted therapy.

Diagram showing various body areas treatable by shockwave therapy, including waist, back, shoulder, arm, neck, and leg.

Image: Illustrates the wide range of application areas for the shockwave therapy, including waist, back, shoulder, arm, neck, and leg.

Diagram showing the operating handle, ballistic projectile, switch button, and five different transmitters with their effective diameters.

Image: Detailed view of the operating handle and the five different transmitters (working heads) with their respective effective diameters (6mm, 10mm, 15mm, 20mm, 25mm).

6. Maintenance

Proper maintenance ensures the longevity and optimal performance of your device.

6.1. Cleaning the Handle's Inner Tube

It is recommended to clean the inner tube of the handle about 1-2 times a week.

  1. Remove the head of the handle.
  2. Carefully take out the cylindrical metal block located inside the handle tube.
  3. Clean the inner tube of the handle using a brush.
  4. Apply 1-2 drops of sewing machine oil onto the cylindrical metal block before reinserting it.
  5. Reinsert the metal block and reattach the handle head.

Important Note: When replacing the working head, be careful not to lose the cylindrical metal block inside the handle. If it falls out, please put it back. If it is lost, use a spare one from the case and place it in the tube of the handle. Without this metal block, there will be no shock wave output.

6.2. Draining Water from the Air Filter

The machine may have small water remains in the air filter due to factory reliability testing. It is normal. Drain water from the air filter after each use.

To drain water from the transparent filter at the back of the instrument, press upward on the needle valve at the bottom of the filter.

Video: Demonstrates the operation to drain water from the air filter located at the back of the machine.

7. Troubleshooting

This section addresses common issues you might encounter.

7.1. No Shock Wave Output

If the machine is powered on but there is no shock wave output from the handle, ensure the cylindrical metal block is correctly placed inside the handle tube. Refer to section 6.1 for instructions on checking and reinserting this component.

7.2. Water Accumulation in Air Filter

It is normal for small amounts of water to accumulate in the air filter. This does not indicate a malfunction. Regularly drain the water as described in section 6.2 to maintain optimal performance.

8. Specifications

ParameterValue
Model NumberQ60-US
VoltageAC110V/AC220V (automatic switch)
Frequency50HZ-60HZ
Power350W Max
Electric Current5A Max
Work Intensity0.5-8.0Bar
Number of Work500-3000 time
Working Probe5
Working Frequency01-22Hz
Product Dimensions16.14 x 14.17 x 6.3 inches
Item Weight26 Pounds
MaterialMetal
Diagram showing the dimensions of the Kalecope Shockwave Therapy Machine and a table of its product parameters.

Image: Visual representation of the machine's dimensions and a summary table of its technical specifications.

9. Support

For any further assistance or inquiries regarding your Kalecope Shockwave Therapy Machine, please refer to the detailed user manual provided with your purchase or contact our customer support for professional assistance.

10. Legal Disclaimer

Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition.

© 2023 Kalecope. All rights reserved.

Related Documents - Q60-US

Preview MAPerformance Z-CBE Exhaust System Installation Guide for Nissan Z & Infiniti Q60
Step-by-step installation instructions for the MAPerformance Z-CBE exhaust system, compatible with 2023+ Nissan Z and 2016+ Infiniti Q60 models. Includes parts list and tools required.
Preview 2015 Infiniti Q60 Convertible Owner's Manual | Infiniti Guide
Your essential guide to the 2015 Infiniti Q60 Convertible. This owner's manual covers features, controls, safety, maintenance, and customer support for the Infiniti Q60.
Preview 2014 Infiniti Q60 Coupe Owner's Manual
Comprehensive owner's manual for the 2014 Infiniti Q60 Coupe. This guide details vehicle features, controls, safety procedures, maintenance, and troubleshooting, ensuring owners can operate their Infiniti safely and efficiently. Includes information on the Intelligent Key system, supplemental restraint systems, and customer support resources.
Preview HYTE THICC Q60 Protocol Documentation: Wiring Diagrams and Pinouts
Detailed technical documentation for the HYTE THICC Q60 liquid cooler, including I-O diagrams, block diagrams of the LCD cap, and comprehensive Type-C connector pinout definitions for power and signal connections.
Preview Quest Q60 Metal Detector Instruction Manual
Comprehensive instruction manual for the Quest Q60 metal detector, covering setup, operation, features, maintenance, and troubleshooting. Includes technical specifications, interface details, and troubleshooting guide.
Preview Z1 Motorsports 370Z / G37 3" Intake Kit Installation Manual
Comprehensive installation guide for the Z1 Motorsports 3" Intake Kit designed for Nissan 370Z and Infiniti G37, Q60, and Q40 models. Includes a detailed parts list, required tools, safety precautions, and step-by-step instructions with textual descriptions of diagrams and images.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.