1. Introduction
This manual provides instructions for the safe and efficient use of your Qlima ASZ 2020 Ash Vacuum Cleaner. Please read it thoroughly before operation and retain it for future reference.
The Qlima ASZ 2020 is designed for the thorough cleaning of cold ash from pellet stoves, wood-burning stoves, fire pits, and grills. It features both suction and blowing functions, a 20-liter collection tank, and a washable HEPA filter for effective dust retention.

An image showing the Qlima ASZ 2020 ash vacuum cleaner. It features a black cylindrical body with a green top handle and filter housing. A black corrugated hose is connected to the side, leading to a silver-colored flat nozzle. The unit is equipped with wheels for mobility.
2. Safety Instructions
To prevent injury or damage to the appliance, always observe the following safety precautions:
- Always ensure the ash is completely cold before vacuuming. Hot ash can cause fire.
- Do not vacuum liquids, glowing embers, or flammable materials.
- Ensure the power supply matches the vacuum cleaner's specifications (220V).
- Do not operate the appliance with a damaged power cord or plug. Contact qualified personnel for repairs.
- Keep children and pets away from the appliance during operation.
- Always unplug the vacuum cleaner from the power outlet before cleaning, maintenance, or when not in use.
- Use only original Qlima accessories and spare parts.
- Do not block the air vents during operation.
3. Package Contents
Verify that all components are present in the package:
- Qlima ASZ 2020 Ash Vacuum Cleaner Unit
- Fire-resistant Aluminum Hose
- Washable HEPA Filter (pre-installed or separate)
- Flat Nozzle
- Wheels (may require attachment)
- Integrated Power Cable
4. Assembly
Follow these steps to assemble your ash vacuum cleaner:
- Attach the wheels to the designated slots on the base of the vacuum cleaner if they are not pre-installed. Ensure they click securely into place.
- Ensure the washable HEPA filter is correctly seated inside the unit's motor housing. Refer to the filter section for proper installation.
- Connect the fire-resistant aluminum hose to the suction inlet on the side of the vacuum cleaner. Twist or push firmly until it is secure.
- Attach the flat nozzle to the free end of the aluminum hose.
5. Operating Instructions
5.1. Preparation
- Verify that the ash to be cleaned is completely cold. Wait at least 24 hours after a fire has extinguished.
- Ensure the HEPA filter is clean and properly installed.
- Plug the power cable into a suitable 220V power outlet.
5.2. Suction Function
- Turn on the vacuum cleaner using the power switch, typically located on the top of the unit.
- Direct the flat nozzle towards the cold ash and begin vacuuming.
- Move the nozzle slowly and steadily to ensure thorough cleaning.
5.3. Blowing Function
The Qlima ASZ 2020 also features a blowing function:
- Unplug the vacuum cleaner.
- Disconnect the hose from the suction inlet.
- Connect the hose to the blowing outlet, usually located on the top or side of the motor unit.
- Plug in the vacuum cleaner and turn it on. Use the blowing function to clear debris from hard-to-reach areas.
5.4. Emptying the Collection Tank
- Unplug the vacuum cleaner from the power outlet.
- Unlatch the clips securing the top motor unit to the collection tank.
- Carefully lift the motor unit off the tank.
- Empty the ash from the collection tank into a suitable, fire-resistant container.
- Clean the inside of the tank if necessary.
- Reassemble the unit, ensuring the filter is correctly positioned and the clips are securely fastened.
6. Maintenance
6.1. Cleaning the HEPA Filter
- Regularly check the HEPA filter for ash buildup. A clogged filter significantly reduces suction power.
- Remove the filter from the unit.
- Tap the filter gently over a waste bin to dislodge loose ash. For thorough cleaning, wash the filter with cold water.
- Allow the filter to air dry completely before re-installing it. Do not use the vacuum cleaner with a wet filter.
6.2. Cleaning the Collection Tank
- Wipe the inside and outside of the collection tank with a damp cloth. Do not use abrasive cleaners or solvents.
- Ensure the tank is completely dry before reassembling the vacuum cleaner.
6.3. Storage
- Store the vacuum cleaner in a dry, cool place, away from direct sunlight and moisture.
- Ensure the power cord is neatly wrapped to prevent damage.
7. Troubleshooting
7.1. No Power
- Check if the power cord is securely plugged into the outlet.
- Verify the power outlet is functional by testing it with another appliance.
- Check the power switch on the unit to ensure it is in the 'ON' position.
7.2. Low Suction Power
- Check if the collection tank is full and needs emptying.
- Inspect the HEPA filter for clogging and clean it as described in the Maintenance section.
- Ensure the hose and nozzle are free from blockages.
- Verify all connections (hose to unit, nozzle to hose) are secure.
7.3. Unusual Noise
- Turn off the unit immediately and unplug it.
- Check for any foreign objects inside the hose or tank.
- If the noise persists after checking, contact customer support.
8. Specifications
| Brand | Qlima |
| Model | ASZ 2020 |
| Model Number | 199833 |
| Power | 1000 W |
| Voltage | 220 V |
| Capacity | 20 Liters |
| Item Weight | 4.5 kg |
| Power Cable Length | 3 meters |
| Filter Type | Washable HEPA, TNT |
| Special Features | Compact, Suction and Blowing Function, Wheels |
9. Warranty and Support
For warranty information, please refer to the documentation provided at the time of purchase or contact your retailer. Warranty terms may vary by region and retailer.
For technical support, spare parts, or any other inquiries regarding your Qlima ASZ 2020 Ash Vacuum Cleaner, please contact Qlima customer service or your authorized dealer. Contact details can typically be found on the product packaging or the manufacturer's official website.