ARLBA W10189190 TSD2

ARLBA W10189190 TSD2 Refrigerator Start Device and W10662129 Capacitor Instruction Manual

Brand: ARLBA

1. Introduction

This manual provides instructions for the installation and maintenance of the ARLBA W10189190 TSD2 Refrigerator Start Device and W10662129 Capacitor. This combination part is designed to replace faulty start relays and capacitors in compatible refrigerators, restoring proper compressor function.

Compatible Models: This start device and capacitor kit is compatible with various refrigerators and freezers from brands including Kenmore, Whirlpool, Amana, Maytag, Jenn-air, Magic Chef, Admiral, Norge, Roper, Caloric, Estate, Crosley, and KitchenAid. Specific compatible model numbers include, but are not limited to: ED5FVGXVS00, ED5KVEXVB01, ED5CHQXVB00, KSRL25FXBL00, KSRL25FXMS00, MSD2254VEQ01, ASD2522WEB01, ASD2522WED01, ASD2522WES01, ASD2522WEW01, ASD2522WRB02, ASD2522WRB03, ASD2522WRD02, ASD2522WRD03, ASD2522WRS02, ASD2522WRS03, W10128791, W10128795, WPW10197428VP, KBFS25EVMS0, mfd 2562vem, eecon jlle, eecon qd tsd2.

Replaces Part Numbers:

  • W10189190 TSD2 Start Relay: W10197428, W10197427, 9793, 14200214, 14203585, 1481748, 2319793, 2319792, 4357156, 2255554, 18516-3, 4344041, 61002047, 61002971, 10097201, 65529-1, 68001457, 68001622, AH2348569, EA23348569 Series, W10448874, 2312074, 241941005, 241941003, 241941004, 23197792, WPW1089190, W2319792, W10448878, 297237702, WR07X10097, WR08X21100.
  • W10662129 Run Capacitor: 2264017, WPW10662129, 2169373, PS11757023, W10590083, WPW10662129VP, Y09100136, Y09100156, 999532, 945508, Y09100173, AP5807758, 2169383, 2188516, 4312484, 4356442, 4356601, 4356995, 4357055, 4357094, 4390503, 4390930, 09100136, 09100156, 09100173, 1118576, 1100804, 1114291, 1118581, 14201635, 14224144, 2169136, 60001028, C8931602, C8931607, R0213143, R0213187, R0651012, R0660030, R0950186, R9800532.
ARLBA Refrigerator Start Device and Capacitor Kit

Image 1: Overview of the ARLBA Refrigerator Start Device and Capacitor Kit.

2. Safety Information

Always prioritize safety when working with electrical appliances. Failure to follow these safety guidelines may result in electric shock, injury, or damage to the appliance.

  • Disconnect Power: Before beginning any repair or installation, always unplug the refrigerator from the power outlet to prevent electric shock.
  • Wear Protective Gear: Use appropriate personal protective equipment, such as gloves and safety glasses.
  • Discharge Capacitor: Capacitors can store an electrical charge even after power is disconnected. If replacing only the capacitor, ensure it is safely discharged before handling. This kit includes a pre-assembled unit, reducing this specific risk.
  • Professional Assistance: If you are unsure about any step or uncomfortable performing the repair, consult a qualified appliance technician.
  • Proper Tools: Use only insulated tools suitable for electrical work.

3. Package Contents

Verify that all components are present and undamaged upon opening the package:

  • 1 x W10189190 TSD2 Refrigerator Start Relay
  • 1 x W10662129 Compressor Run Capacitor
  • 2 x Terminal Blocks
Components of the ARLBA Refrigerator Start Device and Capacitor Kit

Image 2: Individual components of the start device and capacitor kit, including terminal blocks.

4. Setup and Installation

This section outlines the general procedure for replacing the refrigerator start device and capacitor. Specific refrigerator models may vary, so refer to your appliance's service manual if available.

  1. Disconnect Power: Unplug the refrigerator from the electrical outlet.
  2. Access Compressor: Carefully move the refrigerator away from the wall to access the rear. Locate the compressor, typically at the bottom rear of the unit. You may need to remove a rear access panel.
  3. Identify Old Components: The old start relay and capacitor are usually attached to the side of the compressor. Note their orientation and wiring connections.
  4. Remove Old Components: Gently pull the old start relay and capacitor assembly off the compressor terminals. Disconnect any wires attached to the old components. Take a photo before disconnecting if unsure.
  5. Connect New Components: The new ARLBA W10189190 TSD2 start relay and W10662129 capacitor come pre-assembled. Connect the refrigerator's wiring to the new terminal blocks provided, then attach these to the new start relay. Ensure connections are secure.
  6. Install New Assembly: Carefully push the new start relay and capacitor assembly onto the compressor terminals. Ensure it is seated firmly and correctly.
  7. Secure and Restore: Reattach any access panels removed. Carefully move the refrigerator back into its original position.
  8. Restore Power: Plug the refrigerator back into the electrical outlet. The compressor should start, and the refrigerator should begin cooling.
Technician installing refrigerator start device

Image 3: Illustration of a technician performing the installation of a refrigerator start device.

Diagram showing installation steps for refrigerator start device

Image 4: Step-by-step diagram illustrating the installation process for the start relay and capacitor.

5. Operation

Once correctly installed, the ARLBA W10189190 TSD2 Refrigerator Start Device and W10662129 Capacitor will enable the refrigerator's compressor to start and run efficiently, restoring the appliance's normal cooling function. No user interaction is required for the operation of this component after installation.

6. Maintenance

The start device and capacitor are sealed units and do not require routine maintenance. However, to ensure optimal performance and longevity of your refrigerator:

  • Periodically clean the area around the compressor and condenser coils to prevent dust and debris buildup, which can hinder heat dissipation and strain components.
  • Ensure adequate ventilation around the refrigerator.
  • If you notice any unusual noises or performance issues, consult the troubleshooting section or a qualified technician.

7. Troubleshooting

If your refrigerator is still not functioning correctly after installing the new start device and capacitor, consider the following:

  • Refrigerator Not Starting: Ensure the refrigerator is properly plugged into a working electrical outlet. Check the circuit breaker. Verify that the new start device and capacitor are securely attached to the compressor terminals and that all wiring connections are firm.
  • Clicking Sound, No Cooling: A clicking sound followed by no compressor start often indicates an issue with the start relay or compressor. If the new part is installed correctly and this persists, the compressor itself may be faulty, or there might be another electrical issue.
  • Inadequate Cooling: If the compressor runs but cooling is insufficient, this part is likely not the cause. Check condenser coils for cleanliness, evaporator fan operation, and refrigerant levels (requires professional service).
  • Loose Connections: Re-check all electrical connections to ensure they are tight and correctly positioned.

If troubleshooting steps do not resolve the issue, it is recommended to contact a qualified appliance repair technician for further diagnosis.

8. Specifications

FeatureSpecification
ManufacturerARLBA
Part NumberW10189190 TSD2
Item Weight2.89 ounces
Product Dimensions3.11 x 2.11 x 2.08 inches
Voltage100 Volts
Horsepower0.33 Horsepower
Product dimensions diagram for refrigerator start device and capacitor

Image 5: Detailed dimensions of the W10189190 TSD2 Start Device and W10662129 Capacitor.

Multiple views of the W10189190 TSD2 Refrigerator Start Relay

Image 6: Various angles of the W10189190 TSD2 Refrigerator Start Relay.

Multiple views of the W10662129 Compressor Run Capacitor

Image 7: Various angles of the W10662129 Compressor Run Capacitor.

9. Warranty and Support

ARLBA provides a 36-month warranty for this product. If you encounter any questions or dissatisfaction with the product, please contact ARLBA customer service. We are committed to providing satisfactory solutions and 24-hour service.

For support, please refer to the contact information provided with your purchase or visit the ARLBA brand store online.