Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of the DAVITU XINJE TouchWin TG765 series Human Machine Interface (HMI) touch screens. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage.
Product Overview
The DAVITU XINJE TouchWin TG765 series HMI is a 7-inch touch screen designed for industrial control applications. It features a high-resolution display and multiple communication options to interface with various programmable logic controllers (PLCs) and other devices.

An image showing the DAVITU XINJE TouchWin TG765 series HMI touch screen unit, black in color, resting on its brown cardboard packaging box. The screen displays a dark interface, and the box features the 'TouchWin' logo.
Model Differences
- TG765-MT: Equipped with a USB-B port for connectivity.
- TG765-UT: Features both a USB-B port and a USB-A port.
- TG765-ET: Includes a USB-B port, a USB-A port, and an Ethernet port for network communication.
- TG765-XT-C: A streamlined version of the HMI, typically featuring essential functionalities.
Key Features
- Processor: ARM9 CPU with 400MHz dominant frequency.
- Memory & Storage: 128MB of memory and 128MB storage capacity.
- Display: 7.0-inch TFT LCD with 16 million colors, LED backlight, and 800x480 resolution.
- Communication Ports: Two independent COM ports supporting 232, 485, and 422 communication protocols. Allows multiple screens to use one HMI.
- USB Ports: Two USB ports (USB-A and USB-B) for fast data transfer and storage, including front and rear USB-A interfaces for data backup.
- Ethernet Support: Supports multiple Ethernet communication protocols, including MODBUS TCP devices and S7-1200 PLCs (for TG765-ET model).
- Real-time Clock: Standard built-in clock function.
Setup
- Power Supply: Connect the HMI to a stable DC power source. Ensure the voltage matches the device's requirements.
- Software Installation: The necessary software for the HMI is provided free of charge. If you cannot download it, please contact support to receive it via email. Install the software on your computer.
- Communication Cable: To establish communication between the HMI and your PLC, a specific cable is required. Please specify the brand and model of your PLC when requesting the appropriate communication cable.
- Initial Connection: Connect the HMI to your computer using the appropriate USB port (USB-B for most models). Use the provided software to configure the HMI settings and upload your project.
Operating Instructions
Once the HMI is powered on and configured, it operates as an interface for your industrial control system. The touch screen allows for intuitive interaction with your programmed applications.
- Touch Interface: Navigate through screens and interact with controls by touching the display.
- Data Transfer: Utilize the USB-A ports (if available on your model) for quick data transfer and backup of project files or logs.
- Communication: The COM ports facilitate communication with PLCs and other serial devices. Ensure correct protocol settings (232, 485, 422) are configured in the HMI software.
- Ethernet Communication: For models with an Ethernet port (e.g., TG765-ET), connect to a network to communicate with MODBUS TCP devices or S7-1200 PLCs.
Maintenance
Regular maintenance ensures the longevity and optimal performance of your HMI unit.
- Cleaning: Gently wipe the touch screen with a soft, lint-free cloth. For stubborn marks, use a screen cleaner specifically designed for electronic displays. Avoid abrasive materials or harsh chemicals.
- Environmental Conditions: Ensure the HMI operates within its specified temperature and humidity ranges to prevent damage.
- Firmware Updates: Periodically check for firmware updates from the manufacturer to improve performance and add new features.
- Data Backup: Regularly back up your HMI project files and critical data to an external storage device using the USB-A port or network connection.
Troubleshooting
This section addresses common issues you might encounter with your HMI.
| Problem | Possible Cause | Solution |
|---|---|---|
| HMI does not power on. | No power supply or incorrect voltage. | Verify power cable connection and ensure the DC power supply meets the HMI's voltage requirements. |
| Display is blank or distorted. | Loose display cable, software issue, or backlight failure. | Restart the HMI. If the problem persists, check internal connections (if accessible) or contact technical support. |
| Communication with PLC fails. | Incorrect cable, wrong communication settings, or PLC not responding. | Ensure the correct communication cable is used. Verify COM port settings (baud rate, data bits, parity, stop bits) in both HMI and PLC. Check PLC status. |
| Touch screen is unresponsive. | Software freeze or physical damage. | Perform a soft reset of the HMI. If unresponsive, power cycle the device. If physical damage is suspected, contact support. |
Specifications
| CPU | ARM9, 400MHz |
| Memory | 128MB |
| Storage Capacity | 128MB |
| Display Size | 7.0 inches |
| Display Type | TFT LCD, LED backlight |
| Color Depth | 16 million colors |
| Resolution | 800 x 480 pixels |
| COM Ports | 2 (supporting 232, 485, 422) |
| USB Ports | USB-B (all models), USB-A (TG765-UT, TG765-ET) |
| Ethernet Port | Yes (TG765-ET model only) |
| Real-time Clock | Standard |
| Power Supply | DC |
Warranty and Support
Specific warranty details are not provided within the product information. For warranty claims, technical support, or inquiries regarding software and communication cables, please contact your vendor or the manufacturer directly. Ensure you have your product model and purchase details available when seeking support.