1. Introduction
Product Overview
The GX PUMP L3 is a portable PCP air compressor designed for inflating airguns, rifles, paintball tanks, and mini diving tanks up to 4500 Psi (320 Bar/32 Mpa). It features dual 18V lithium batteries for cordless operation, an automatic shut-off function, a built-in oil-water separator, and an integrated cooling fan, offering convenience and efficiency for various high-pressure air needs.

2. Safety Instructions
Adhere to the following safety guidelines to ensure safe operation and prevent damage to the unit or injury.
- Do not start the machine under internal pressure. Starting the compressor with existing pressure in the system can cause damage.
- Always release the bleed valve after turning off the power, including during the shutdown cooling cycle.
- Ensure adequate ventilation during operation to prevent overheating.
- The cooling fan is manual; allow the machine to cool down after each use before turning off the power completely.
- For optimal performance and longevity, operate the machine for a maximum of 15 minutes, then allow it to rest for 10 minutes.
- If inflating mini diving tanks for actual diving, it is recommended to use an additional air filter separator for air purity.

3. Package Contents
Please verify that all the following items are present in your package:
- 1 x GX PUMP L3 Air Compressor Machine
- 1 x Instruction Manual
- 2 x 18V Lithium Batteries
- 2 x Battery Chargers
- 1 x Pull Rod
- 1 x 19mm Socket Spanner
- 1 x First Stage Piston Ring
- 2 x Wrenches (12-14mm, 14-17mm)
- 2 x Springs
- 10 x Burst Discs
- 6 x Allen Wrenches (2mm, 2.5mm, 3mm, 4mm, 5mm, 7mm)
4. Setup
Battery Installation and Removal
The compressor operates with two 18V lithium batteries. Ensure they are charged before installation.
- Installation: Place the battery into the slot in direction 1 and then push it in direction 2 until it clicks securely.
- Removal: Press the red button in direction 1 and push the battery out in direction 2.

Initial Connections
Connect the high-pressure hose to the compressor's quick connector. Ensure all connections are secure before operation to prevent air leaks.

5. Operating Instructions
Charging the Batteries
Each 18V lithium battery takes approximately 2 hours to fully charge. A fully charged battery provides about 30 minutes of operation, with two batteries offering up to an hour of continuous use. You can charge one battery while using the other, allowing for extended operation.

Inflation Procedure
- Connect: Securely attach the compressor's 8mm quick female connector to the air inlet of the tank or device you intend to inflate.
- Power On: Ensure both 18V lithium batteries are installed. Turn on the main power switch (ON/OFF).
- Set Pressure: Use the pressure gauge to set the desired inflation pressure. The compressor will automatically shut off once this pressure is reached.
- Start Compressor: Press the "START" button to begin the inflation process.
- Monitor: Observe the pressure gauge during inflation.
- Automatic Shut-off: The compressor will stop pumping air when the preset pressure is achieved. The cooling fan will continue to operate.
- Bleed Valve: After the compressor stops, or if you need to pause, slowly open the bleed valve to release residual pressure from the hose before disconnecting.
- Disconnect: Once pressure is released, disconnect the hose from your device.

Cooling and Shutdown
The compressor features a built-in cooling fan. After each inflation cycle, allow the fan to run to cool the machine before turning off the main power switch. This practice extends the lifespan of the unit. Always release the bleed valve after turning off the power.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your compressor.
- Cooling Intervals: To protect the pump and extend its life, adhere to the recommended duty cycle: operate the machine for a maximum of 15 minutes, then allow it to rest for 10 minutes.
- Oil-Water Separator: The built-in oil-water separator ensures dry and clean air. Regularly check and maintain this component as per the detailed instructions in the full manual (if available) to prevent moisture from entering your air system.
- Storage: Store the compressor in a clean, dry environment away from direct sunlight and extreme temperatures.
7. Troubleshooting
Common Issues and Solutions
- Compressor does not start:
- Ensure batteries are fully charged and correctly installed.
- Verify the main power switch is in the "ON" position.
- Check if the bleed valve is closed before starting. The machine cannot start under internal pressure.
- Slow inflation or low pressure:
- Check for leaks in connections.
- Ensure the tank or device being filled is within the compressor's capacity (maximum 1L tank recommended).
- Allow the compressor to cool if it has been running continuously for an extended period.
- Batteries drain quickly:
- Ensure batteries are fully charged before use.
- Note that battery life is approximately 30 minutes per battery, or 60 minutes with two.
- Consider the ambient temperature, as extreme cold can affect battery performance.
- Overheating:
- Adhere to the 15 minutes on / 10 minutes off duty cycle.
- Ensure the cooling fan is operating correctly and not obstructed.
- Do not obstruct the air vents on the compressor.
8. Specifications
| Feature | Value |
|---|---|
| Brand | GX pump |
| Model Name | GX PUMP L3 |
| Model Number | GX-E-L3 |
| Maximum Operating Pressure | 4500 Psi / 320 Bar / 32 Mpa |
| Power Source | Battery Powered (Dual 18V Lithium Batteries) |
| Voltage | 18 Volts |
| Maximum Power | 250 Watts |
| Air Flow Capacity | 14 Liters Per Minute |
| Noise Level | 72 Decibels |
| Item Weight | 17.8 Pounds (approx.) |
| Product Dimensions | 9.65"L x 5.71"W x 10.63"H |
| Tank Volume Capacity | 1 Liter (maximum recommended) |
| Special Features | Automatic Shut-Off, Built-in Oil-Water Separator, Cooling Fan |
| Compatible Hose Diameter | 8 Millimeters |
9. Warranty and Support
GX PUMP provides a 12-month warranty for replacement or return if the product cannot be fixed. This warranty covers manufacturing defects and malfunctions under normal use from the date of purchase.
For technical support, warranty claims, or further assistance, please refer to the contact information provided with your purchase documentation or visit the official GX PUMP website for the most up-to-date support resources.