1. Product Overview
The amiciSmart 63A Single Phase Circuit Breaker is designed to provide comprehensive electrical protection for your home or industrial applications. It integrates leakage current protection, lightning protection, and visual indicators for operational status. This device is suitable for DIN rail mounting and operates on a 220VAC/230VAC single-phase supply.
Image 1.1: Front view of the amiciSmart 63A Single Phase Circuit Breaker.
2. Safety Information
WARNING: Electrical installation should only be performed by a qualified electrician. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always disconnect power at the main supply before installing or servicing the circuit breaker.
- Ensure the product is wired correctly as per the provided diagrams and local electrical codes. Incorrect wiring can lead to product damage or safety hazards.
- Do not operate the device if it appears damaged or malfunctioning.
- This device is designed for single-phase 220VAC/230VAC systems with a maximum current rating of 63 Amps. Do not exceed these ratings.
3. Product Features
- Leakage Current Protection: Features 30mA leakage current protection to safeguard against electrical shocks.
- Lightning Protection: Built-in lightning protection also functions as a surge protector.
- Visual Grounding Indicator: A green LED indicates if excess current is being safely grounded.
- Visual Open and Close Indicators (LEDs): Clear LEDs show the operational status (ON/OFF) of the circuit breaker.
- Manual Test Button: Allows for periodic testing to ensure the mechanical integrity and proper functioning of the device.
- DIN Rail Mounted Design: Easy installation into standard electrical distribution boards.
Image 3.1: Detailed product overview highlighting terminals, basic parameters, operating handle, test button, and indicators.
4. Setup and Installation
The amiciSmart 63A Circuit Breaker is designed for DIN rail mounting. Follow these steps for proper installation:
- Power Disconnection: Before beginning any installation, ensure the main power supply to the circuit is completely disconnected.
- Mounting: Securely attach the circuit breaker to a standard DIN rail within your electrical distribution board.
- Wiring: Connect the input and output wires according to the wiring diagram. Pay close attention to the Line (L), Neutral (N), and Protective Earth (PE) connections. The device is a 2-pole breaker for single-phase applications.
Image 4.1: Wiring diagram for the amiciSmart 63A Single Phase Circuit Breaker. Ensure correct connection of Line (L), Neutral (N), and Protective Earth (PE) wires.
Note: Ensure the product is wired as shown in the image; failure to do so may result in damage to the product and potential safety hazards.
5. Operating Instructions
Once installed and wired correctly, operating the circuit breaker is straightforward:
- Switching ON/OFF: Use the operating handle to switch the circuit breaker ON (handle UP) or OFF (handle DOWN).
- Visual Indicators:
- Power Indicator (Red LED): Illuminates when the circuit breaker is ON and power is flowing.
- Ground Indicator (Green LED): Illuminates when excess current is being grounded, indicating proper leakage protection function.
- Open/Close Status: The position of the operating handle visually indicates whether the circuit is open (OFF) or closed (ON).
- Manual Test Button: Press the "Test" button periodically (e.g., monthly) to verify the mechanical operation of the circuit breaker and its leakage protection function. The breaker should trip when the test button is pressed. Reset the breaker after testing.
Image 5.1: Visual indicators for the circuit breaker's open and closed status, showing the handle positions.
6. Maintenance
The amiciSmart 63A Circuit Breaker requires minimal maintenance. Regular checks ensure continued safety and performance:
- Monthly Test: Press the Manual Test Button at least once a month to confirm the leakage protection mechanism is functioning correctly.
- Visual Inspection: Periodically inspect the device for any signs of physical damage, discoloration, or loose connections.
- Cleaning: Keep the device free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquids or abrasive cleaners.
7. Troubleshooting
If you encounter issues with your amiciSmart 63A Circuit Breaker, consider the following:
- Constant Tripping: If the device trips constantly after installation, this indicates a leakage in your electrical system that needs to be addressed. Consult a qualified electrician to identify and rectify the source of the leakage.
- Device Not Resetting: If the circuit breaker does not reset after tripping, ensure the fault condition (e.g., overload, short circuit, leakage) has been cleared. If the issue persists, the device may be faulty and require replacement.
- No Power Indication: Check the main power supply to the circuit. If the supply is active and the breaker is ON but the power indicator is off, the device may be faulty.
8. Specifications
| Specification | Detail |
|---|---|
| Brand | amiciSmart |
| Model Number | 63A |
| Current Rating | 63 Amps |
| Voltage | 230 Volts (AC) |
| Number of Poles | 2 |
| Circuit Breaker Type | Standard |
| Mounting Type | DIN Rail Mount |
| Product Dimensions | 6D x 10W x 9H Centimeters |
| Item Weight | 340 g |
| Country of Origin | China |
| Date First Available | 31 August 2021 |
Image 8.1: Product dimensions of the amiciSmart 63A Circuit Breaker.
9. Warranty and Support
This amiciSmart 63A Single Phase Circuit Breaker comes with a 1-year warranty from the date of purchase.
For any technical queries, warranty claims, or support, please contact amicikart. Their contact information is typically found on the product packaging or purchase documentation.
Manufacturer: Shenzhen Shengtai E-Trade Co. Ltd
Packer: Amicikart Online Services Pvt Ltd, A-28B, Sector-58, Noida (Contact No.-9809709898)
Importer: Amici Import Export