Replacement Part Instruction Manual
The Mavrik Exact Fit for Newco 110574 Limit Thermostat is a high-limit, disc-type replacement part designed for specific coffee brewing equipment. This thermostat, identified as INT02L, is set to a temperature of 230 degrees Fahrenheit. It is compatible with various BUNN-O-MATIC COFFEE BREWERS, including the C12 series, and other series such as BCO, BCM2, BL, BT, C, CG, CRTF, CT, CTF, CTFG, CTG, CWAPS, CWG, CWT, CWTAPS, CWTFCOMB, CWTFG, CWTFTS, and CWTG, CWTS.

Figure 1: Mavrik Exact Fit Newco 110574 Limit Thermostat. This image shows the compact, disc-type thermostat with two metal mounting tabs extending from its sides, each with a hole for secure attachment. The main body is dark, and the disc face is metallic grey with embossed markings.
Always disconnect power to the appliance before attempting any installation, maintenance, or repair. Wear appropriate personal protective equipment (PPE) such as safety glasses and gloves. If you are unsure about any step, consult a qualified technician.
This thermostat is a direct replacement part. Follow the specific service manual for your BUNN-O-MATIC coffee brewer model for detailed installation instructions. General steps typically include:
The Mavrik Exact Fit Newco 110574 Limit Thermostat is an automatic safety component. It is designed to monitor and limit the temperature within the coffee brewer. When the internal temperature reaches 230 degrees Fahrenheit, the thermostat will open its circuit, interrupting power to the heating element to prevent overheating. Once the temperature drops to a safe level, the thermostat will automatically reset and close the circuit, allowing the heating element to resume operation.
No user intervention is required for the operation of this thermostat. Its function is entirely passive and protective.
The Mavrik Exact Fit Newco 110574 Limit Thermostat is a sealed component and requires no routine maintenance. However, it is recommended to:
If your coffee brewer is experiencing issues related to overheating or not heating at all, the limit thermostat could be a contributing factor. Before troubleshooting, always ensure the appliance is unplugged and cooled.
| Symptom | Possible Cause | Solution |
|---|---|---|
| Brewer not heating / No power to heating element | Tripped or faulty limit thermostat | Check for continuity across the thermostat terminals with a multimeter (when cool). If no continuity, the thermostat may be faulty and require replacement. Ensure the brewer is not overheating, which would cause the thermostat to trip. |
| Brewer overheating / Excessive temperature | Faulty limit thermostat (stuck closed) | If the thermostat fails to open at its set temperature (230°F), it needs to be replaced immediately to prevent damage or safety hazards. This is a critical safety component. |
| Intermittent heating | Loose wiring or intermittent thermostat failure | Inspect all wiring connections to the thermostat for tightness. If connections are secure, the thermostat may be failing intermittently and should be replaced. |
Note: Troubleshooting electrical components should only be performed by individuals with appropriate knowledge and tools. If you are not comfortable performing these checks, consult a qualified service technician.
Mavrik OEM-equivalent parts are designed to meet strict quality standards. This product is backed by a 90-day return policy and an unbeatable 180-day warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use.
For warranty claims, technical support, or further assistance, please contact your point of purchase or visit the official Mavrik website. When contacting support, please have your product model (Newco 110574 equivalent) and purchase information readily available.
For more information about Mavrik products, you can visit the Mavrik Store on Amazon.
![]() |
Newco Little Joe Brewer Manual: Operation, Setup, and Specifications Comprehensive user manual for the Newco Little Joe coffee brewer. Includes setup instructions, operation guides, troubleshooting, specifications, and warranty information from Newco Enterprises Inc. |
![]() |
Newco R & L Series Coffee Brewers Spare Parts Catalog Comprehensive spare parts catalog for Newco R & L Series coffee brewers, listing cover assemblies, tank assemblies, valve assemblies, and miscellaneous components with item numbers, descriptions, and units of measure. |
![]() |
StrikerVR Mavrik-Pro Product Manual: VR Gaming Controller Guide Comprehensive product manual for the StrikerVR Mavrik-Pro VR gaming controller, detailing its features, setup, operation, maintenance, and specifications. Learn about Active Touch technology, charging, and integration. |
![]() |
FIT Battery Ultracore 48V Instruction Manual | Models 500081, 501215, 500256, 501216 Comprehensive instruction manual for the FIT Battery Ultracore 48V e-bike battery. Learn about installation, operation, safety, troubleshooting, and maintenance for models 500081, 501215, 500256, and 501216. |
![]() |
FIT Battery Supertube 48 V Instruction Manual Official instruction manual for the FIT Battery Supertube 48 V e-bike battery. Provides essential information on safe operation, technical specifications, installation, charging, maintenance, troubleshooting, and disposal. |
![]() |
FIT TP FIT 48 V E-Bike Battery Instruction Manual Comprehensive instruction manual for the FIT TP FIT 48 V e-bike battery, covering specifications, safety, operation, troubleshooting, and disposal. Learn how to properly use, charge, and maintain your FIT e-bike battery. |