1. Product Overview
The NEXPEAK NC201 is an advanced 7-stage fully-automatic battery charger, maintainer, and desulfator designed for a wide range of 12V and 24V lead-acid batteries. It intelligently detects battery voltage and capacity, providing efficient and safe charging for various vehicles and equipment.
Key features include a pulse repair mode for restoring old batteries, an integrated thermal sensor for temperature-adaptive charging, and multiple safety protections. The intuitive LCD screen provides real-time charging information, making it easy to monitor the process.

Figure 1: NEXPEAK NC201 Battery Charger with included accessories.
2. Safety Instructions
Please read and understand all safety information before using this product. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ventilation: Ensure adequate ventilation during charging. Batteries can produce explosive gases.
- Eye Protection: Always wear eye protection when working with batteries.
- Skin Protection: Avoid contact with battery acid. Wear protective gloves.
- Ignition Sources: Keep sparks, flames, and smoking materials away from the battery and charger.
- Connection Order: Connect the charger to the battery first, then plug it into the power outlet. Disconnect in reverse order.
- Damaged Batteries: Do not attempt to charge frozen or visibly damaged batteries. This charger cannot charge totally dead batteries.
- Children and Pets: Keep the charger and battery out of reach of children and pets.
- Indoor Use: This charger is designed for indoor use. Do not expose to rain or excessive moisture.
3. Product Components
The NEXPEAK NC201 charger includes the following main components:
- Main Charger Unit: Features an LCD display, touch switch for mode selection, and built-in cooling fan.
- Battery Clamps: Durable red (positive) and black (negative) clamps for connecting to battery terminals.
- AC Power Cord: For connecting the charger to a standard wall outlet.

Figure 2: Multi-protection features of the charger, including overheat, pulse repair, reverse polarity, overcurrent, intelligent detection, overvoltage, short-circuit, and cooling function.
4. Technical Specifications
| Feature | Specification |
|---|---|
| Input Voltage | Standard AC (as per power cord) |
| Output Voltage | 12 Volts (DC) / 24 Volts (DC) |
| Charging Current | 10 Amps (for 12V) / 5 Amps (for 24V) |
| Battery Types | Lead-acid (Flooded, Gel, AGM, Maintenance-Free) |
| Battery Capacity Range | 2AH ~ 150AH |
| Charging Stages | 7-Stage Automatic Charging |
| Display | LCD Backlit Digital Screen |
| Protections | Overheat, Pulse Repair, Reverse Polarity, Overcurrent, Overvoltage, Short Circuit, Fire-proof, Temp Calibration |
| Dimensions | 9.06 x 5.12 x 2.56 inches |
| Weight | 1.32 pounds (0.6 Kilograms) |
| Operating Temperature | Temperature-adaptive (Summer Mode above 82.4°F/28°C, Winter Mode below 50°F/10°C) |
5. Setup and Connection
Follow these steps to safely connect the charger to your battery:
- Prepare the Battery: Ensure the battery terminals are clean and free of corrosion. If necessary, clean them with a wire brush.
- Connect Red Clamp: Attach the red positive (+) clamp securely to the positive battery terminal.
- Connect Black Clamp: Attach the black negative (-) clamp securely to the negative battery terminal.
- Plug into Power: Once both clamps are securely attached to the battery, plug the AC power cord into a standard wall outlet. The charger will automatically detect the battery voltage and begin the charging process.
To disconnect, reverse the order: first unplug the AC power cord from the wall outlet, then remove the black negative (-) clamp, and finally remove the red positive (+) clamp.

Figure 3: Proper connection of the positive clamp to the battery terminal.

Figure 4: Illustration of the 7-stage charging process and its benefits for battery health.
6. Operating Modes
The NEXPEAK NC201 features a touch switch for selecting different operating modes to suit various battery types and conditions. The LCD screen will display the selected mode.

Figure 5: The intelligent digital display and touch switch for mode selection.
- STD (Standard): For standard lead-acid batteries.
- AGM/GEL: For AGM (Absorbed Glass Mat) and Gel batteries.
- WET: For wet cell batteries.
- Motorcycle: Optimized charging for motorcycle batteries.
- Repair: Pulse repair mode designed to restore old, idle, damaged, stratified, or sulfated batteries. Select this mode by pressing the touch switch until the "Repair" indicator lights up.
The charger also automatically adjusts to ambient temperature, entering "Summer Mode" above 82.4°F (28°C) and "Winter Mode" below 50°F (10°C) to prevent over-charging or under-charging.

Figure 6: Automatic temperature compensation for extreme weather conditions.
7. Charging Process and LCD Display
Once connected and powered on, the charger's intelligent automatic detection system will identify the battery type and condition, then initiate the appropriate 7-stage charging cycle. The LCD display provides comprehensive real-time information:
- Charging Status: Indicated by a battery icon with charge level.
- Battery Status: Shows the current charge percentage (20%, 40%, 60%, 80%, 100%).
- Charging Current: Displays the current flowing into the battery (Amps).
- Voltage: Shows the battery's voltage (Volts).
- Environment Temp: Displays the ambient temperature.
- Compensation Mode: Indicates if Summer or Winter mode is active.
- Repair Mode: Indicated when pulse repair is active.
- Battery Full: "FUL" displayed when charging is complete.
- Error: "E++" displayed for reverse connection or other errors.
The charger automatically stops charging once the battery is fully charged, preventing overcharge. It can be left connected for long-term maintenance.

Figure 7: Example of LCD display readings.
8. Maintenance
To ensure optimal performance and longevity of your NEXPEAK NC201 charger:
- Cleaning: Wipe the charger's exterior with a soft, dry cloth. Do not use harsh chemicals or abrasives.
- Storage: Store the charger in a cool, dry place when not in use. Keep cables neatly coiled.
- Cable Inspection: Regularly inspect the power cord and battery clamps for any signs of damage, fraying, or corrosion. Do not use if damaged.
- Ventilation: Ensure the cooling fan vents are not obstructed during operation.
9. Troubleshooting
If you encounter issues with your NEXPEAK NC201 charger, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Charger not turning on / LCD blank | No power from outlet; incorrect connection to battery; battery completely dead. | Check wall outlet power. Ensure clamps are securely connected to battery terminals. This charger cannot charge totally dead batteries. |
| "E++" error displayed | Reverse polarity connection. | Disconnect the charger immediately. Reconnect the red clamp to positive (+) and black clamp to negative (-) terminals. |
| Charging is slow or not reaching 100% | Battery sulfation; incorrect mode selected; extreme temperature. | Try "Repair" mode for sulfated batteries. Ensure correct battery type mode is selected. Allow charger to adapt to temperature or move to a more moderate environment. |
| Charger gets hot | Normal operation; obstructed cooling fan. | A slight warmth is normal. Ensure cooling fan vents are clear and not obstructed. The built-in cooling fan prevents overheating. |
10. Warranty and Support
The NEXPEAK NC201 Battery Charger comes with an 18-month quality warranty. If you experience any issues or have questions regarding the product, please contact NEXPEAK customer support for assistance. Please retain your proof of purchase for warranty claims.
For further support, visit the official NEXPEAK website or contact their customer service department through the contact information provided with your product packaging.