Temtop PMS 8+ Pump Suction Laser Particle Sensor User Manual
Model: PMS 8+
1. Introduction
The Temtop PMS 8+ is a pump-suction laser dust (particulate matter) monitor designed for accurate air quality assessment. This device features a cost-effective double channel, making it small and easy to install. It is widely utilized in atmospheric monitoring systems, including miniature air stations, dust monitoring, and smoke monitoring systems. This manual provides essential information for the proper installation, operation, and maintenance of your PMS 8+ sensor.

Figure 1: Front view of the Temtop PMS 8+ Pump Suction Laser Particle Sensor. This image shows the compact black casing with the Temtop logo and model number, along with the input/output terminals at the bottom.
2. Key Features
- 2 Channels Particle Size Monitoring: Simultaneously detects the mass concentration of particulate matter for PM10 and TSP with a rapid sampling time of 10 seconds.
- Precise Calibration: Manufacturer calibration benchmarking using the beta ray method reduces the need for secondary calibration.
- Efficient Sampling with Vacuum Pump: Equipped with a brushless vacuum pump ensuring a stable flow rate of 1.1 L/min for accurate measurements.
- Strong Anti-interference: Features an all-metal precision optomechanical structure design for enhanced anti-interference capabilities.
- Long Hours of Operation: Designed for durability, supporting over 10,000 hours of operation, especially in intermittent mode, due to industrial-grade core components like lasers and air pumps.
3. Specifications
| Parameter | Value |
|---|---|
| Model | PMS 8+ |
| Particle Size Range | PM10, TSP |
| Accuracy (0~100µg/m³) | ±10µg/m³ |
| Accuracy (>100µg/m³) | ±10% |
| Measurement Range | 0~10,000µg/m³ |
| Resolution | 1µg/m³ |
| Principle | Light Scattering |
| Laser Source | Long Life Laser Diode |
| Flow Rate | 1.1 L/min (Accuracy ±5%) |
| Sampling Mode | Continuous Mode/Intermittent Mode (Settable, continuous mode by default) |
| Sampling Time | 10sec~24hrs (Settable, 60sec by default) |
| Sampling Rate | Continuous/10sec~24hrs (Settable, 60sec by default) |
| Stable Time | <10sec (Sampling Stable Time) |
| Communication Interface | RS485 |
| Working Voltage | 12~24 VDC |
| Working Current | 300mA |
| Working Temperature | 0~50 ℃ |
| Storage Temperature | -10~60 ℃ |
| Dimension | 113mm x 88mm x 38mm (Excluding inlet & outlet terminal) |
| Lifespan | >10,000 hours (on intermittent mode) |
4. Setup and Installation
Proper installation is crucial for the accurate operation of the PMS 8+ sensor. Follow these guidelines:
- Mounting: Securely mount the sensor in a stable location, away from direct sunlight, strong vibrations, and extreme temperature fluctuations. Ensure adequate airflow around the device.
- Power Connection: Connect the sensor to a 12-24 VDC power supply using the designated terminals. Observe correct polarity to prevent damage.
- Communication Interface: Connect the RS485 interface to your monitoring system. Refer to your system's documentation for specific wiring instructions.
- Inlet and Outlet Terminals: Ensure the inlet and outlet terminals are clear and unobstructed. The pump-suction mechanism requires a clear path for air sampling.

Figure 2: Side view of the Temtop PMS 8+ sensor, highlighting the green terminal block for power and communication, and the inlet/outlet ports. This view helps in identifying connection points during installation.
5. Operation
The PMS 8+ operates automatically once powered and configured. Here are key operational aspects:
- Power On: Once connected to the power supply, the sensor will initiate its startup sequence. Allow approximately 10 seconds for the sensor to stabilize before reliable readings are available.
- Sampling Modes: The sensor supports both Continuous Mode and Intermittent Mode. The default setting is Continuous Mode. You can configure the sampling mode and sampling time (10 seconds to 24 hours) via the RS485 communication interface, depending on your monitoring system's capabilities.
- Data Output: Particle concentration data for PM10 and TSP is transmitted via the RS485 interface. Consult the communication protocol documentation for details on data interpretation and integration with your system.
- Environmental Conditions: Operate the sensor within the specified working temperature range of 0~50 ℃ to ensure optimal performance and longevity.
6. Maintenance
Regular maintenance ensures the accuracy and extends the lifespan of your PMS 8+ sensor.
- Cleaning: Periodically inspect the air inlet and outlet for any dust accumulation or obstructions. Gently clean with a soft, dry cloth. Do not use liquids or abrasive materials.
- Environmental Control: Maintain a clean environment around the sensor to minimize the ingress of large particles or debris that could affect the pump or laser.
- Calibration: The sensor is factory-calibrated. If you suspect a significant deviation in readings, contact Temtop support for guidance on re-calibration procedures.
- Storage: When not in use for extended periods, store the sensor in a dry environment within the specified storage temperature range of -10~60 ℃.
7. Troubleshooting
This section addresses common issues you might encounter with the PMS 8+ sensor.
| Problem | Possible Cause & Solution |
|---|---|
| No power/device unresponsive |
|
| Inaccurate or inconsistent readings |
|
| No data output via RS485 |
|
| Pump noise or reduced airflow |
|
If the problem persists after attempting these solutions, please contact Temtop customer support for further assistance.
8. Warranty and Support
Temtop products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the official Temtop website or contact their customer service department. Ensure you have your product model (PMS 8+) and purchase details available when contacting support.
You can find more information and contact details on the Temtop Brand Store.