EVTSCAN HF-5111B

EVTSCAN Logo

EVTSCAN HF-5111B Serial Server User Manual

RS232/RS485/RS422 to Ethernet Converter

1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the EVTSCAN HF-5111B Serial Server. The HF-5111B is a versatile 3-in-1 device designed to convert RS232, RS485, or RS422 serial data to Ethernet, enabling seamless communication between serial devices and network-based systems. It is suitable for various industrial and IoT applications.

2. Product Features

The EVTSCAN HF-5111B Serial Server incorporates advanced features for reliable and secure serial-to-Ethernet conversion:

HF-5111B Serial Network Server with key features listed

Image: Overview of HF-5111B Serial Network Server highlighting virtual serial port, remote control, automatic IP acquisition, and RS232/485/422 support.

3. Package Contents

Verify that all items are present in the package:

Note: Power adapter is not included and must be purchased separately. Only one serial interface type (RS232, RS485, or RS422) can be connected at a time.

EVTSCAN HF-5111B Serial Server with included serial and Ethernet cables

Image: The HF-5111B Serial Server unit shown with a DB9 serial cable and an RJ45 Ethernet cable, representing the typical package contents.

4. Physical Description and Connections

The HF-5111B features an industrial-grade metal enclosure designed for durability. Key connection points and indicators are located on the device:

Front and back view of EVTSCAN HF-5111B Serial Server showing all ports

Image: Top panel showing the DB9 RS232 port and a reset button. Bottom panel showing the RJ45 Ethernet port, terminal block for RS485/RS422 and power, and DC jack.

5. Technical Specifications

Item Type:
3 in 1 Serial Port RS232 RS485 RS422 to Ethernet Converter
Enclosure:
Industrial-grade metal enclosure
MCU Type:
Cortex-M3, 96 MHz, 2 MB Flash, 128 KB RAM
Operating System:
FreeRTOS
Interfaces:
3 x UART Ports (RS232/RS485/RS422), 1 x RJ45 10/100 Mbps Ethernet Port (Auto-sensing)
Serial Interfaces:
DB9 female connector (RS232); Terminal block connector (RS485/RS422)
Baud Rates:
600 bps to 460.8 kbps
Data Bits:
5, 6, 7, 8
Stop Bits:
1, 2
Parity:
None, Even, Odd
Flow Control:
Hardware
Network Protocols:
TCP/IP, UDP, ICMP, DHCP, DNS, HTTP, ARP, Telnet, Modbus TCP, BOOTP, AutoIP, ICMP, Web socket, uPNP, NTP
Network Security:
SSL/TLS, AES, DES3
Software Support:
Configuration via web browser interface, Optional software for configuration and monitoring, Supports firmware upgrades
LED Indicators:
Power Indicator, Ethernet Link Indicator, Activity Indicator
Power Supply:
5-36V DC Input, 5.5mm x 2.1mm DC jack or 5.08mm terminal block
Protection:
Isolation, Surge protection, ESD protection
Earth:
Yes
Reset Button:
Yes
Dip Switch Configuration:
Yes
Operating Temperature:
-40°C to 85°C
Dimensions:
95mm x 65mm x 25mm (L x W x H)
Mounting Options:
Wall mounting or DIN rail (Bracket not included)
Application Areas:
Industrial automation, Building automation, Remote monitoring and control, IoT applications, PLC communication, SCADA systems, access control, and more.
Dimensions of the EVTSCAN HF-5111B Serial Server

Image: Diagram showing the dimensions of the HF-5111B Serial Server as 95mm (3.7in) length, 65mm (2.6in) width, and 25mm (1in) height.

6. Installation and Setup

Follow these steps to install and set up your HF-5111B Serial Server:

  1. Power Connection: Connect a 5-36V DC power adapter (not included) to the DC jack or the terminal block. Ensure correct polarity.
  2. Ethernet Connection: Connect the provided Ethernet cable from the HF-5111B's RJ45 port to your network switch or router.
  3. Serial Device Connection: Connect your serial device to the appropriate port on the HF-5111B. Use the DB9 connector for RS232 or the terminal block for RS485/RS422. Remember: Only one serial interface type can be active at a time.
  4. Power On: Once all connections are secure, apply power to the device. The Power LED should illuminate.
  5. Initial Configuration: The device can be configured via a web browser. Refer to the product documentation or the manufacturer's website for default IP address and login credentials.
EVTSCAN HF-5111B Serial Server connected to Ethernet and serial devices

Image: The HF-5111B Serial Server with an Ethernet cable connected to the RJ45 port and a DB9 serial cable connected to the RS232 port, illustrating a typical setup.

7. Operation

The HF-5111B acts as a bridge, allowing serial devices to communicate over an Ethernet network. After successful setup and configuration, the device will transparently transmit data between the connected serial port and the network.

Diagram showing basic function of HF-5111B connecting serial devices to network

Image: A diagram illustrating the HF-5111B's basic function, showing RS232, RS485, and RS422 devices connecting to the server, which then connects to a wired network.

8. Maintenance and Firmware Updates

Regular maintenance ensures optimal performance and longevity of your serial server.

Diagram illustrating network remote firmware upgrade process

Image: A diagram showing how firmware updates are managed remotely, with an IoT Bridge and IoT Service checking for updates and pushing them to multiple devices.

9. Troubleshooting

If you encounter issues with your HF-5111B, consider the following:

10. Safety Information

Observe the following safety precautions:

11. Support and Warranty

For technical support or warranty inquiries, please contact EVTSCAN customer service through their official website or the retailer from whom the product was purchased. Keep your purchase receipt as proof of purchase.

Manufacturer: EVTSCAN

Model Number: HF-5111B

Related Documents - HF-5111B

Preview HF2211 Serial Server Device User Manual
User manual for the HF2211 Serial Server Device, detailing its features, hardware, network configurations (AP, STA, AP+STA), Ethernet functions (Router, Bridge), and applications. It enables RS232/RS485/RS422 to Ethernet/Wi-Fi conversion.
Preview Siemens S7-1500/ET 200MP Communications Module CM PtP RS422/485 BA/HF User Manual
Comprehensive guide to the Siemens S7-1500/ET 200MP Communications Module CM PtP RS422/485 BA/HF, covering installation, configuration, programming, and technical specifications for industrial automation.
Preview Protoss-PE11 RS485 to Ethernet User Manual
User manual for the Protoss-PE11, a device that converts RS485 serial communication to Ethernet TCP/IP data transfer. Details features, specifications, hardware introduction, pin definitions, and applications.
Preview Protoss-PE11 RS485 to Ethernet Converter User Manual | HF IoT
Comprehensive user manual for the Protoss-PE11, an industrial RS485 to Ethernet converter. Features include Cortex-M3 MCU, FreeRTOS, multiple protocols (TCP/UDP/MQTT/HTTP/WebSocket), Modbus, and industrial temperature range. Learn about hardware, installation, and specifications.
Preview HF Series Digital Force Gauge Manual - Precision Measurement Tool
Comprehensive manual for the HF Series Digital Force Gauge, detailing its functional characteristics, specifications, safe usage, and operational modes for accurate force measurement.
Preview Protoss-PW11 RS485 to Wi-Fi Converter User Manual
User manual for the Protoss-PW11, a versatile RS485 to Wi-Fi converter designed for industrial control, smart grid, and remote monitoring applications. Learn about its features, specifications, network configurations, and installation.