Introduction
This manual provides detailed instructions for the setup, operation, and maintenance of your TFA Dostmann INFO 30.3065.02 Wireless Digital Thermometer. This device is designed to accurately display indoor temperature and humidity, and wirelessly transmit outdoor temperature data. Please read this manual thoroughly before using the device to ensure proper function and longevity.

Figure 1: The TFA Dostmann INFO 30.3065.02 Wireless Digital Thermometer, showing the main display unit with indoor and outdoor temperature readings, humidity, and max/min values. Two AA alkaline batteries are also depicted, indicating they are included for operation.
Package Contents
Verify that all items are present in the package:
- 1 x TFA Dostmann INFO 30.3065.02 Wireless Digital Thermometer (Main Unit)
- 1 x Outdoor Transmitter (Model: 30.3234.02)
- 4 x 1.5V AA Alkaline Batteries (2 for Main Unit, 2 for Outdoor Transmitter)
- 1 x User Manual
Note: The product description mentions "2 high-quality 1.5V AA alkaline batteries included". Please verify the exact number of batteries provided in your package, as wireless devices typically require batteries for both the main unit and the external sensor.
Setup
1. Battery Installation
- Main Unit: Open the battery compartment cover on the back of the main display unit. Insert two 1.5V AA alkaline batteries, observing the correct polarity (+/-). Close the cover securely.
- Outdoor Transmitter: Open the battery compartment cover on the back of the outdoor transmitter (Model 30.3234.02). Insert two 1.5V AA alkaline batteries, observing the correct polarity (+/-). Close the cover securely.
- After inserting batteries, the main unit will power on and begin searching for the outdoor sensor signal.
2. Sensor Placement
- Main Unit: Place the main unit indoors in a location where you wish to monitor temperature and humidity. Ensure it is away from direct sunlight, heat sources, or drafts that could affect readings. The unit can be placed on a flat surface using its integrated stand or mounted on a wall.
- Outdoor Transmitter: Position the outdoor transmitter in a sheltered outdoor location, protected from direct rain and sunlight, to ensure accurate temperature readings and prolong its lifespan. Avoid placing it near metal objects or large electrical appliances that could interfere with the wireless signal. The maximum transmission range is approximately 100 meters in open areas.
3. Initial Synchronization
Once both units have batteries installed and are placed within range, the main unit will automatically attempt to connect with the outdoor transmitter. This process may take a few minutes. The outdoor temperature reading will appear on the main display once a connection is established. If the outdoor temperature does not appear, try repositioning the outdoor transmitter or pressing the reset button (if available) on both units.
Operating Instructions
1. Display Overview
The large display shows the following information:
- OUT: Outdoor temperature (transmitted wirelessly from the outdoor sensor).
- IN: Indoor temperature.
- Humidity (%): Indoor humidity level.
- HI/LOW 24HR: Maximum and minimum recorded values for outdoor temperature, indoor temperature, and indoor humidity over the last 24 hours.
2. Max/Min Function
The device automatically records the highest (HI) and lowest (LOW) temperature and humidity values over a 24-hour period. These values are displayed on the right side of the screen. The 24-hour cycle typically resets automatically. Refer to the specific buttons on your device (if any) for manually clearing or viewing these records.
Maintenance
1. Battery Replacement
When the display becomes dim or readings are inconsistent, it is time to replace the batteries.
- Replace all batteries in both the main unit and the outdoor transmitter simultaneously to ensure optimal performance and synchronization.
- Always use new, high-quality 1.5V AA alkaline batteries.
- Dispose of old batteries according to local regulations.
2. Cleaning
To clean the device:
- Gently wipe the display and casing with a soft, dry cloth.
- Do not use abrasive cleaners, solvents, or polishes, as these can damage the display or casing.
- Keep the device away from liquids.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No outdoor temperature display. |
|
|
| Inaccurate readings. |
|
|
| Display is dim or blank. |
|
|
Technical Specifications
| Model | TFA Dostmann INFO 30.3065.02 |
| Indoor Temperature Range | -10 °C to +60 °C |
| Outdoor Temperature Range | -40 °C to +60 °C |
| Indoor Humidity Range | 10 % to 99 % RH |
| Humidity Accuracy | ± 3 % (within 35 % to 75 % RH) |
| Transmission Frequency | 433 MHz |
| Dimensions (Main Unit) | 77 x 22 x 86 mm |
| Power Supply | Main Unit: 2 x 1.5V AA Alkaline Batteries Outdoor Transmitter: 2 x 1.5V AA Alkaline Batteries |
| Mounting Options | Table standing or wall hanging |
| Material | Plastic |
Safety Information
- Do not expose the device to extreme temperatures, vibrations, or shocks.
- Keep the device away from strong magnetic fields.
- Do not immerse the device in water or other liquids.
- Do not attempt to open or modify the device. This will void the warranty.
- Keep batteries out of reach of children. If swallowed, seek medical attention immediately.
- Dispose of batteries and the device responsibly according to local environmental regulations.
Warranty and Support
Information regarding specific warranty terms and customer support for the TFA Dostmann INFO 30.3065.02 is typically provided with the product packaging or on the manufacturer's official website. Please refer to these resources for details on warranty coverage, returns, and technical assistance.
For further assistance, please contact TFA Dostmann customer service or visit their official website.