EVTSCAN DTS6619-016

EVTSCAN DTS6619-016 3-Phase Energy Meter User Manual

Model: DTS6619-016 | Brand: EVTSCAN

1. Introduction

This manual provides essential information for the safe and efficient operation of your EVTSCAN DTS6619-016 3-Phase Energy Meter. Please read this manual thoroughly before installation and use, and keep it for future reference. This device is designed for accurate measurement of active energy in 3-phase 4-wire systems.

2. Safety Information

WARNING: Installation and maintenance should only be performed by qualified personnel. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Product Features

The EVTSCAN DTS6619-016 energy meter offers a range of features for comprehensive energy monitoring:

4. Specifications

ParameterValue
Type3-Phase Energy Meter
ModelDTS6619-016 (LCD Display)
Reference Voltage (Un)220/380V, 230/400V, 240/415V
Operating Voltage181-279V AC (3~) / 300-500V AC (3~)
Rated Current (Ib)1.5A, 5A, 10A, 15A, 20A, 30A
Maximum Current (Imax)6A, 20A, 40A, 60A, 80A, 100A
Starting CurrentNot more than 0.004 Ib
Tolerance Overload Current30 Imax for 0.01 seconds
Working Frequency50 Hz ± 10%
Internal Power ConsumptionNot more than 2W / 10VA
Pulse Constant400 imp/1600 imp
Data Storage Duration> 20 years
Operating HumidityNot more than 75%
Operating Temperature-10 ℃ ~ +50 ℃
Storage HumidityNot more than 95%
Storage Temperature-30 ℃ ~ +70 ℃
International StandardIEC 62053-21
AccuracyLevel 1
Dust and Water ResistanceIP 51
Protection Insulation TypeII

5. Setup and Installation

The DTS6619-016 energy meter is designed for DIN rail mounting. Follow these steps for proper installation:

  1. Power Disconnection: Ensure all power to the installation area is completely disconnected before beginning.
  2. Mounting: Securely attach the meter to a standard 35mm DIN rail in an appropriate electrical enclosure.
  3. Wiring: Connect the input and output wires according to the wiring diagram provided below. Pay close attention to the phase (A, B, C) and neutral (N) connections, as well as the RS485 and pulse output terminals.
  4. Verification: Double-check all connections for tightness and correctness.
  5. Power Restoration: Once all connections are verified, restore power to the system.
Wiring diagram for EVTSCAN DTS6619-016 3-Phase Energy Meter

Figure 5.1: Wiring diagram for the DTS6619-016 energy meter. Connect phases A, B, C, and Neutral (N) to the corresponding terminals (1-7). RS485 (A+, B-) and Pulse output terminals are also indicated (15-18).

Installation of EVTSCAN DTS6619-016 3-Phase Energy Meter in an electrical panel

Figure 5.2: The DTS6619-016 energy meter being installed in an electrical panel, demonstrating its DIN rail mounting capability.

6. Operating Instructions

The DTS6619-016 meter features an LCD display and two control buttons: "TURN" and "SET".

Front view of EVTSCAN DTS6619-016 3-Phase Energy Meter with LCD display and buttons

Figure 6.1: Front view of the DTS6619-016 energy meter, showing the LCD display and the "TURN" and "SET" buttons.

7. Maintenance

The EVTSCAN DTS6619-016 energy meter is designed for minimal maintenance.

8. Troubleshooting

If you encounter issues with your energy meter, refer to the following common problems and solutions:

ProblemPossible CauseSolution
No display / Meter not powering onNo power supply; Incorrect wiring; Internal fault.Check power supply to the meter. Verify wiring connections according to the diagram. If problem persists, contact support.
Incorrect readingsIncorrect wiring; Meter not calibrated (unlikely for new unit); External interference.Verify all wiring connections. Ensure the meter is installed correctly for a 3-phase 4-wire system. If readings are consistently inaccurate, contact support.
PULSE LED not flashingNo load connected; Meter not receiving power; Internal fault.Ensure there is an active load connected to the circuit being measured. Check power supply. If problem persists, contact support.
RS485 communication failureIncorrect RS485 wiring; Incorrect communication settings; Device address conflict.Verify RS485 A+ and B- connections. Check communication parameters (baud rate, parity, stop bits). Ensure unique device addresses if multiple meters are on the bus.

For issues not covered here, please contact EVTSCAN customer support.

9. Warranty and Support

EVTSCAN products are manufactured to high-quality standards. While specific warranty details are not provided in this manual, please retain your proof of purchase for any warranty claims.

For technical support, troubleshooting assistance, or warranty inquiries, please contact EVTSCAN customer service through their official website or the retailer from whom you purchased the product.

Manufacturer: EVTSCAN
Model Reference: EVTSCANq8o9dbfveg (Internal reference, not the product model number)

Related Documents - DTS6619-016

Preview LiteTrac (White) 1-Phase Track Lighting System | hidealite
Explore the hidealite LiteTrac (White) 1-phase track lighting system. This document details components, specifications, safety instructions, and installation examples for creating versatile lighting solutions.
Preview Pfister Park Avenue 016-FEO Diverter Trim: Maintenance, Care, and Warranty Guide
Comprehensive guide for the Pfister Park Avenue 016-FEO Diverter Trim, covering maintenance, care instructions, parts identification, and warranty information.
Preview CHIKO CK-Steel Solar Carport/Gazebo Installation Manual
Installation manual for the CHIKO CK-Steel Solar Carport/Gazebo, detailing components, tools, and step-by-step assembly instructions for a 3-car premier model. Includes maintenance, safety warnings, and component lists.
Preview YS-016 Dial Combination Padlock User Manual
User manual for the Xuzhou Bamenjin Electronic Technology Co., Ltd. YS-016 Dial Combination Padlock. Details features, technical parameters, installation, operation, and maintenance.
Preview BRILO Bewegungsmelder mit Mikrowellensensor: Einstellungshinweise
Umfassende Anleitung zur Konfiguration von BRILO Mikrowellen-Bewegungsmeldern. Erfahren Sie, wie Sie Empfindlichkeit, Erfassungsbereich, Einschaltdauer und Helligkeitsschwelle mit DIP-Schaltern einstellen. Enthält Details zu Modellen wie 7187-016, 7188-016, 7189-016, 3362-016 und 3362-116.
Preview KV-016 Karaoke Speaker System: Instructions for Use and Specifications
User manual for the Shenzhen Daisi Technology KV-016 karaoke speaker system, providing instructions for setup, Bluetooth connection, microphone operation, charging, troubleshooting, and technical specifications.