Introduction
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Stealth ECV05S1 5 Gallon 5.5 Peak HP Stainless Steel Wet/Dry Vacuum. Please read these instructions thoroughly before initial use and retain for future reference.
Safety Information
Always observe basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, or injury.
- Read All Instructions: Familiarize yourself with the vacuum's functions and safety warnings.
- Electrical Safety: Do not operate with a damaged cord or plug. Ensure the power source matches the vacuum's requirements (120V / 60Hz). Unplug the vacuum before cleaning or performing maintenance.
- Flammable Materials: Never vacuum flammable or combustible liquids, hot ashes, or explosive dusts.
- Supervision: Do not leave the vacuum unattended while plugged in. Keep children and pets away from the appliance.
- Proper Filtration: Always use the correct filter for wet or dry applications to protect the motor.
- Indoor Use: This appliance is recommended for indoor use.
What's Included
Your Stealth ECV05S1 Wet/Dry Vacuum package includes the following components:
- Stealth 5 Gallon Stainless Steel Wet/Dry Vacuum (x1)
- Hose (1-1/4" x 4.9') (x1)
- Extension Wands (x3)
- Floor Brush (x1)
- Foam Filter (x1)
- Crevice Nozzle (x1)
- Dust Bag (x1)
- Cotton Filter (x1)
- Sofa Brush (Gulper Nozzle) (x1)
- User Manual (x1)

Setup
Follow these steps to assemble your wet/dry vacuum:
- Unpack Components: Carefully remove all items from the packaging. Inspect for any damage.
- Attach Casters: Insert the four casters into the designated slots on the base of the vacuum for mobility.
- Filter Installation:
- For Dry Vacuuming: Ensure the cotton filter and dust bag are securely installed over the motor housing.
- For Wet Vacuuming: Remove the cotton filter and dust bag. Install the foam filter over the motor housing.
- Connect Hose: Insert the hose into the vacuum port on the front of the unit. Ensure it is securely locked in place. For blowing function, insert the hose into the blower port located at the rear.
- Attach Accessories: Connect the desired extension wands and nozzles (floor brush, crevice nozzle, sofa brush) to the end of the hose for specific cleaning tasks.

Operating Instructions
Your Stealth ECV05S1 vacuum offers three primary functions: wet vacuuming, dry vacuuming, and blowing.
Dry Vacuuming
- Ensure the cotton filter and dust bag are correctly installed.
- Connect the hose to the vacuum port.
- Plug the power cord into a suitable electrical outlet.
- Turn the ON/OFF switch to the 'ON' position.
- Use appropriate attachments for dry debris such as dust, dirt, and pet hair.
Wet Vacuuming
- Remove the cotton filter and dust bag. Install the foam filter over the motor housing.
- Connect the hose to the vacuum port.
- Plug the power cord into a suitable electrical outlet.
- Turn the ON/OFF switch to the 'ON' position.
- Vacuum liquids. The integrated buoy technology will automatically shut off suction when the tank reaches its maximum liquid capacity to prevent overflow and protect the motor.
- Empty the tank immediately after wet vacuuming.
Blower Function
- Connect the hose to the blower port located at the rear of the vacuum.
- Plug the power cord into a suitable electrical outlet.
- Turn the ON/OFF switch to the 'ON' position.
- Use the blower function to clear debris from surfaces or dry wet areas.



Maintenance
Regular maintenance ensures optimal performance and extends the life of your vacuum.
- Emptying the Tank: After each use, especially wet vacuuming, unlatch the motor head and empty the contents of the stainless steel tank. Clean the tank with water and mild detergent if necessary.
- Filter Cleaning:
- Cotton Filter & Dust Bag: For dry use, regularly shake out or gently brush the cotton filter and replace the dust bag when full. These are reusable and washable.
- Foam Filter: For wet use, rinse the foam filter with water after each use and allow it to air dry completely before reinstallation.
- Hose and Accessories: Clean the hose and attachments as needed to prevent blockages. Store accessories on the integrated on-board storage.
- Power Cord: Wrap the power cord neatly around the designated hooks for storage.


Troubleshooting
If you encounter issues with your vacuum, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Vacuum does not turn on. | No power, switch off, or damaged cord. | Check power outlet, ensure switch is ON, inspect power cord for damage. |
| Loss of suction. | Clogged filter, full tank, hose blockage, or improper filter installation. | Clean/replace filter, empty tank, clear hose/attachments, ensure correct filter for application. |
| Water overflow during wet vacuuming. | Tank is full, buoy activated. | Empty the tank. The buoy system is designed to prevent overfilling. |
| Unusual noise during operation. | Motor issue, foreign object in impeller, or loose components. | Turn off and unplug. Inspect for obstructions. If noise persists, contact support. |
Specifications
| Feature | Detail |
|---|---|
| Model Name | ECV05S1 Wet/Dry Vacuum |
| Capacity | 5 Gallon |
| Motor Horsepower | 5.5 Peak HP |
| Tank Material | Stainless Steel |
| Voltage/Frequency | 120V / 60Hz |
| Power | 1000W |
| Power Cord Length | 19.6 ft (6m) |
| Hose Length | 4.9 ft (1.5m) |
| Noise Level | <82dB |
| Product Dimensions | 14"L x 14"W x 18"H |
| Item Weight | 16.66 pounds |
| Special Features | Wet/Dry/Blow 3-in-1, HEPA filtration system, On-board accessory storage, Safety buoy technology |
Warranty and Support
Your Stealth ECV05S1 Wet/Dry Vacuum comes with a 2-year limited warranty. This warranty covers defects in materials and workmanship under normal use. For warranty claims, technical support, or replacement parts, please refer to the contact information provided in your warranty card or visit the official Stealth website.