1. Introduction

The AmScope LED-144W-ZK is a 144-LED intensity adjustable ring light designed for stereo microscopes and camera applications. This illuminator provides cool, even, intense, and focused shadow-free illumination, enhancing visibility for detailed work. It features variable intensity control and operates with a wide range of power supplies (100-240V).

2. Safety Information

  • Ensure the power adapter is connected to a compatible power outlet (100-240V, 50-60Hz).
  • Do not open the unit; there are no user-serviceable parts inside.
  • Keep the device away from water or excessive moisture.
  • Avoid direct eye exposure to the LED light at maximum intensity.
  • Unplug the power adapter before cleaning or moving the unit.

3. Package Contents

Verify that all items are present in the package:

  • 1x AmScope LED-144W-ZK 144 LED Ring Light
  • 1x Power Adapter (100-240V)
  • 1x 1-7/8" (48 mm) Ring Adapter

4. Product Overview

The AmScope LED-144W-ZK ring light is designed for optimal illumination in microscopy. Key features include:

  • 144 bright white LED bulbs for intense and focused shadow-free illumination.
  • Adjustable intensity control for precise lighting adjustments.
  • Wide power input compatibility: 100-240V, 50-60Hz with auto-switching.
  • Color temperature of 6000K for natural daylight simulation.
  • Designed with a 2.5" (62.5mm) inside diameter and 3.64" (92.5mm) overall outside diameter.
  • Includes a 1-7/8" (48 mm) ring adapter for versatile mounting.
AmScope LED-144W-ZK Ring Light, Power Adapter, and Ring Adapter

Figure 4.1: Complete AmScope LED-144W-ZK package contents, including the 144 LED ring light, power adapter, and a smaller ring adapter.

AmScope LED-144W-ZK Ring Light with dimensions

Figure 4.2: Front view of the AmScope LED-144W-ZK ring light, illustrating its 2.5 inch (62.5mm) inner diameter and 3.64 inch (92.5mm) outer diameter.

5. Setup

  1. Identify Mounting Point: Locate the appropriate mounting area on your stereo microscope. The ring light is designed to fit objectives with a diameter up to 2.5 inches (62.5mm). For smaller objectives, the included 1-7/8" (48 mm) ring adapter can be used.
  2. Attach Ring Light:
    • Loosen the three thumbscrews on the ring light.
    • Carefully slide the ring light onto the microscope objective or the provided ring adapter, ensuring it is seated securely.
    • Gently tighten the three thumbscrews to secure the ring light in place. Avoid over-tightening to prevent damage.
    AmScope LED-144W-ZK Ring Light showing mounting screws and depth

    Figure 5.1: Underside view of the AmScope LED-144W-ZK ring light, highlighting the three mounting screws and the 2.5 inch (62.5mm) mounting diameter.

  3. Connect Power: Plug the power adapter into the DC input port on the ring light. Then, plug the power adapter into a standard electrical outlet (100-240V).
AmScope LED-144W-ZK Ring Light mounted on a stereo microscope

Figure 5.2: An AmScope LED-144W-ZK ring light properly installed on a stereo microscope, demonstrating its typical application.

6. Operating Instructions

  1. Power On/Off: Locate the power switch on the side of the ring light. Flip the switch to the "ON" position to turn on the LEDs. Flip it to "OFF" to turn them off.
  2. Adjust Brightness: Use the rotary knob, typically located next to the power switch, to adjust the intensity of the LED illumination. Turn the knob clockwise to increase brightness and counter-clockwise to decrease it. Adjust the brightness to achieve optimal viewing conditions without glare.

7. Maintenance

  • Cleaning: Ensure the unit is unplugged before cleaning. Use a soft, dry cloth to wipe the exterior of the ring light. Do not use liquid cleaners or abrasive materials, as these may damage the LEDs or housing.
  • Storage: When not in use for extended periods, store the ring light in a clean, dry environment, protected from dust and extreme temperatures.
  • Inspection: Periodically inspect the power cord and adapter for any signs of damage. If damage is found, discontinue use and contact support.

8. Troubleshooting

ProblemPossible CauseSolution
No light from LEDsPower adapter not connected or faulty. Power switch is off.Ensure power adapter is securely plugged into both the ring light and a working electrical outlet. Turn the power switch to the "ON" position. Test the outlet with another device.
Uneven or dim illuminationBrightness knob set too low. LEDs are dirty.Rotate the brightness knob clockwise to increase intensity. Gently clean the LED surface with a soft, dry cloth.
Ring light is loose on microscopeMounting screws are not tightened. Incorrect adapter used.Gently tighten the three thumbscrews on the ring light. Ensure the correct ring adapter (if needed) is used and properly seated.

9. Specifications

ModelLED-144W-ZK
Light Source144 LED bulbs
Color Temperature6000K
Power Input100-240V, 50-60Hz (Auto-switching)
Inside Diameter2.5" (62.5 mm)
Overall Outside Diameter3.64" (92.5 mm)
Ring Adapter Diameter1-7/8" (48 mm)
MaterialPlastic
ColorWhite
Item Weight0.01 Ounces
Product Dimensions7.09 x 5.79 x 2.13 inches
Compatible DevicesStereo Microscopes, Cameras

10. Warranty and Support

Warranty: This AmScope LED-144W-ZK ring light comes with a one-year warranty against manufacturing defects.

Support: For further assistance, technical support, or warranty claims, please visit the official AmScope Store or refer to the comprehensive user manual available in PDF format.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.