Thank you for choosing the Qlima WDH 229 Inverter Monobloc Air Conditioner. This manual provides essential information for the safe and efficient operation, installation, maintenance, and troubleshooting of your new air conditioning unit. Please read this manual thoroughly before using the appliance and keep it for future reference.
2. Safety Information
Always observe the following safety precautions to reduce the risk of fire, electric shock, or injury.
- Ensure the power supply matches the voltage specified on the unit's rating label.
- Do not operate the unit with a damaged cord or plug.
- Keep the air inlet and outlet clear of obstructions.
- Do not insert objects into the air vents.
- Unplug the unit before cleaning or performing any maintenance.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
3. Product Overview
The Qlima WDH 229 is a compact and efficient monobloc air conditioner designed for cooling and dehumidifying spaces up to 85 m³.

Front view of the Qlima WDH 229 Inverter Monobloc Air Conditioner. It features a white casing, a horizontal air outlet grille near the top, and a black control panel with indicator lights and buttons below it.
Key Components:
- Air Outlet: Adjustable louvers for directing airflow.
- Control Panel: Buttons for power, mode selection, fan speed, temperature adjustment, and timer. Includes indicator lights.
- Air Inlet: Located on the rear or sides (not visible in front view) for drawing in room air.
- Exhaust Hose Connection: For expelling hot air outside.
- Drainage Port: For condensate water removal.
4. Setup
Placement:
- Place the unit on a flat, stable surface.
- Ensure there is at least 30 cm (12 inches) of space around the unit for proper air circulation.
- Position the unit near a window or door for easy exhaust hose installation.
Installation:
- Attach the exhaust hose to the designated port on the rear of the unit.
- Extend the exhaust hose and secure the window kit adapter to the end of the hose.
- Open a window or sliding door and install the window kit, ensuring a tight seal to prevent hot air from re-entering the room.
- Plug the power cord into a grounded electrical outlet.
5. Operating Instructions
Control Panel Functions:
- Power Button (U): Turns the unit ON or OFF.
- Mode Button (M): Cycles through operating modes: Cool, Fan, Dehumidify.
- Temperature Up/Down Buttons (^ / v): Adjusts the desired temperature in Cool mode.
- Fan Speed Button (O): Selects fan speed (Low, Medium, High) in Cool or Fan mode.
- Timer Button (Clock icon): Sets the auto-on or auto-off timer.
Operating Modes:
- Cool Mode: Provides cooling. Set desired temperature and fan speed.
- Fan Mode: Circulates air without cooling. Adjust fan speed as needed.
- Dehumidify Mode: Removes moisture from the air. Fan speed is typically fixed to low in this mode.
6. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner.
Air Filter Cleaning:
- The air filter should be cleaned every two weeks or more frequently depending on usage.
- Unplug the unit before cleaning.
- Remove the air filter from its housing (refer to diagram in full manual for location).
- Wash the filter with warm, soapy water. Rinse thoroughly and allow it to air dry completely before reinserting.
Unit Exterior Cleaning:
- Wipe the exterior with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.
Seasonal Storage:
- Before storing, run the unit in Fan mode for a few hours to dry out any internal moisture.
- Drain any accumulated water from the drainage port.
- Clean the air filter.
- Store the unit in a dry, cool place, covered to protect from dust.
7. Troubleshooting
Before contacting customer service, please refer to the following table for common issues and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on | No power supply; Power cord not plugged in; Circuit breaker tripped. | Check power outlet; Plug in power cord securely; Reset circuit breaker. |
| Unit does not cool effectively | Air filter clogged; Room too large; Doors/windows open; Exhaust hose not properly installed. | Clean air filter; Ensure room size is within unit capacity; Close doors/windows; Check exhaust hose connection. |
| Unusual noise | Unit not on a level surface; Obstruction in fan. | Place unit on a flat surface; Check for and remove any obstructions (unplug first). |
| Water leakage | Drainage plug loose; Drainage hose blocked. | Ensure drainage plug is secure; Clear any blockages in the drainage hose. |
8. Specifications
Detailed technical specifications for the Qlima WDH 229 Inverter Monobloc Air Conditioner.
| Feature | Specification |
|---|---|
| Brand | Qlima |
| Model Number | WDH 229 |
| Dimensions (L x W x H) | 10 x 10 x 10 cm (approximate) |
| Weight | 42.5 kilograms |
| Voltage | 293 Volts |
| Wattage | 293 Watts |
| Energy Efficiency | High |
| Special Features | Inverter Compressor, Silent Mode |
| Color | White |
| Control Method | Remote Control |
9. Warranty and Support
The Qlima WDH 229 Inverter Monobloc Air Conditioner comes with a limited warranty. Please refer to the warranty card included with your purchase for specific terms and conditions.
For technical support, spare parts, or warranty claims, please contact your local Qlima dealer or authorized service center. Keep your purchase receipt as proof of purchase.
Note: Information regarding the availability of spare parts is currently unavailable.