1. Introduction
This manual provides essential instructions for the safe and efficient operation, setup, and maintenance of your Global Industrial 30 KW Portable Electric Heater, Model 246553. This robust electric heater is designed for use in ventilated indoor spaces such as greenhouses and conservatories, providing consistent warm temperatures. Please read this manual thoroughly before operating the unit and retain it for future reference.
2. Safety Information
WARNING: Failure to follow these safety instructions may result in electric shock, fire, property damage, or serious injury.
- Always ensure the heater is connected to a properly grounded 480V, 3-phase power supply.
- Do not operate the heater with a damaged cord or plug. If the cord or plug is damaged, contact qualified service personnel.
- Maintain a minimum clearance of 3 feet (0.9 meters) from all combustible materials, walls, and objects around the heater.
- Do not block air intakes or exhaust openings. Ensure proper ventilation during operation.
- This heater is designed for indoor use in ventilated spaces. Do not use outdoors or in wet locations.
- Do not insert fingers or foreign objects into any ventilation or exhaust opening.
- The heater surface can become hot during operation. Avoid direct contact.
- Always unplug the heater before performing any maintenance or cleaning.
- Do not use this heater in areas where gasoline, paint, or flammable liquids are stored or present.
- The unit features a built-in sensor that automatically shuts off the heater if it reaches an abnormal temperature. If this occurs, unplug the unit, allow it to cool, and inspect for obstructions before restarting.
3. Package Contents
Verify that all components are present and undamaged upon unpacking:
- Global Industrial 30 KW Portable Electric Heater Unit
- Caster Wheels (4)
- Flip-up Metal Handle (pre-attached or requiring minor assembly)
- User Manual (this document)
4. Product Features and Components
Familiarize yourself with the main parts of your heater:

- Heat Exhaust: Large opening at the front for efficient heat distribution.
- Control Panel: Located on the side or top, featuring universal power switches and a dial control for operation.
- Flip-up Metal Handle: For easy gripping and maneuvering of the unit.
- Caster Wheels: Four wheels for convenient portability across even surfaces.
- Safety Sensor: Internal mechanism that automatically shuts off the heater if it overheats.
5. Setup
- Unpacking: Carefully remove the heater from its packaging. Inspect for any shipping damage.
- Caster Wheel Installation (if not pre-installed): Attach the four caster wheels to the designated mounting points on the bottom of the heater using the provided hardware. Ensure they are securely fastened.
- Handle Installation (if not pre-installed): Secure the flip-up metal handle to the top of the unit using the provided hardware.
- Placement: Position the heater on a stable, level surface in the desired ventilated indoor area. Ensure a minimum clearance of 3 feet (0.9 meters) from all walls, furniture, and other objects to allow for proper airflow and prevent fire hazards.
- Power Connection: Connect the heater's power cord to a dedicated 480V, 3-phase grounded electrical outlet. Ensure the outlet is rated for the heater's power requirements.
6. Operating Instructions
- Power On: Ensure the heater is properly plugged into a 480V, 3-phase outlet. Locate the universal power switches on the control panel. Turn the main power switch to the "ON" position.
- Adjust Heat Output: Use the dial control to select the desired heat setting. The dial typically offers various heat levels or temperature ranges.
- Monitoring: The heater will begin to emit warm air from the large heat exhaust. Monitor the area to ensure the desired temperature is reached.
- Automatic Shut-off: The built-in sensor will automatically shut off the heater if it detects an abnormal operating temperature. If this occurs, unplug the unit, allow it to cool for at least 30 minutes, and check for any obstructions around the air intake or exhaust before attempting to restart.
- Power Off: To turn off the heater, rotate the dial control to the "OFF" or lowest setting, then switch the main power switch to the "OFF" position. Unplug the unit from the power outlet when not in use for extended periods.
7. Maintenance
Regular maintenance ensures optimal performance and extends the life of your heater.
- Cleaning: Before cleaning, always unplug the heater and allow it to cool completely. Use a soft, damp cloth to wipe the exterior surfaces. Do not use abrasive cleaners or solvents.
- Air Intakes/Exhaust: Periodically inspect the air intake and exhaust openings for dust, debris, or obstructions. Use a vacuum cleaner with a brush attachment to gently remove any buildup. Ensure these areas remain clear for proper airflow.
- Power Cord: Regularly check the power cord and plug for any signs of damage, fraying, or overheating. If damage is observed, discontinue use and contact qualified service personnel.
- Storage: When not in use, store the heater in a cool, dry place, protected from dust and moisture.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Heater does not turn on. |
|
|
| Heater turns off unexpectedly. |
|
|
| Reduced heat output. |
|
|
If troubleshooting steps do not resolve the issue, contact Global Industrial customer support.
9. Specifications
| Brand | Global Industrial |
| Model Number | 246553 |
| Power Output | 30 KW |
| Voltage | 480V, 3 Phase |
| Fuel Type | Electric |
| Indoor/Outdoor Usage | Indoor |
| Product Dimensions (D x W x H) | 26.38"D x 18.63"W x 24.63"H |
| Item Weight | 113 Pounds |
| Color | Yellow |
| UPC | 707022431507 |