1. Introduction
Thank you for choosing the GREE PURITY Mobile Air Conditioner. This appliance is designed to provide efficient cooling, dehumidifying, and ventilation for your indoor spaces. To ensure safe and optimal operation, please read this manual thoroughly before use and retain it for future reference.
This manual provides detailed instructions on installation, operation, maintenance, and troubleshooting for your mobile air conditioner.
2. Important Safety Instructions
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, or injury.
- Read all instructions before using the appliance.
- Connect to a properly grounded outlet only.
- Do not operate the unit with a damaged cord or plug.
- Do not block air inlets or outlets.
- Keep the appliance away from flammable materials.
- Do not insert fingers or foreign objects into the air outlets.
- Ensure the unit is placed on a flat, stable surface.
- Unplug the unit before cleaning or servicing.
- This appliance uses R290 refrigerant, which is flammable. Handle with care and ensure proper ventilation.
3. Product Overview
Familiarize yourself with the main components of your GREE PURITY Mobile Air Conditioner.

Figure 3.1: Front view of the GREE PURITY Mobile Air Conditioner, showing the control panel at the top and the main air outlet grille.

Figure 3.2: Side view of the GREE PURITY Mobile Air Conditioner, highlighting the side air intake vents.

Figure 3.3: Remote control for the GREE PURITY Mobile Air Conditioner, displaying various function buttons and an LCD screen.

Figure 3.4: Diagram illustrating the dimensions of the GREE PURITY Mobile Air Conditioner: 35.8 cm (depth), 30.4 cm (width), and 80.5 cm (height).
Main Components:
- Control Panel: Located on top of the unit for manual operation.
- Air Outlet: Front grille where conditioned air is discharged.
- Air Inlets: Side grilles for air intake.
- Exhaust Air Outlet: Connection point for the exhaust hose at the rear.
- Casters: Wheels at the base for easy mobility.
- Remote Control: For convenient operation from a distance.
- Drainage Port: For water removal during dehumidifying mode.
4. Setup
4.1 Unpacking
- Carefully remove the air conditioner and all accessories from the packaging.
- Check for any shipping damage. If damaged, do not operate and contact your dealer.
- Retain the original packaging for future storage or transport.
4.2 Exhaust Hose Installation
The exhaust hose is essential for expelling hot air outside the room during cooling and dehumidifying operations.
- Screw the exhaust hose connector onto one end of the exhaust hose.
- Attach the window kit adapter to the other end of the exhaust hose.
- Connect the exhaust hose connector to the exhaust air outlet on the back of the air conditioner by pushing and twisting until it locks into place.
- Adjust the window kit to fit your window opening and secure it. Insert the window kit adapter into the opening of the window kit.
- Ensure the exhaust hose is as short and straight as possible to maximize efficiency. Avoid sharp bends.
4.3 Placement
- Place the unit on a firm, level surface.
- Maintain a minimum distance of 30 cm (12 inches) from walls or other objects to ensure proper airflow.
- Ensure the unit is near a grounded power outlet.
- Do not place the unit in direct sunlight or near heat sources.
5. Operating Instructions
5.1 Control Panel and Remote Control
The unit can be operated via the control panel on top or the included remote control.

Figure 5.1: Remote control layout.
| Button | Function |
|---|---|
| ON/OFF | Turns the unit on or off. |
| MODE | Cycles through operating modes: Cool, Dehumidify, Fan. |
| FAN | Adjusts fan speed (Low, Medium, High, Auto). |
| TEMP +/- | Adjusts the desired temperature (16-30°C). |
| TIMER | Sets the auto-on or auto-off timer. |
| SLEEP | Activates sleep mode for quiet, energy-efficient operation. |
| TURBO | Activates maximum cooling/fan speed for rapid cooling. |
| LIGHT | Turns the display light on or off. |
| HEALTH/SAVE | Activates health or energy-saving functions (refer to specific model features). |
| BLOW | Activates the self-cleaning function (blows air to dry internal components). |
5.2 Operating Modes
Cooling Mode
This mode provides powerful cooling. Hot air is expelled through the exhaust hose.
- Press the MODE button until the 'Cool' indicator lights up.
- Use the TEMP +/- buttons to set your desired temperature (16-30°C).
- Adjust fan speed using the FAN button.
Dehumidifying Mode
This mode removes excess moisture from the air. The fan speed is typically fixed to low in this mode.
- Press the MODE button until the 'Dehumidify' indicator lights up.
- Ensure continuous drainage is set up if operating for extended periods.
Fan Mode
This mode circulates air without cooling or dehumidifying.
- Press the MODE button until the 'Fan' indicator lights up.
- Adjust fan speed using the FAN button.
5.3 Timer Function
The timer allows you to set the unit to turn on or off automatically after a set period.
- With the unit ON or OFF, press the TIMER button.
- Use the TEMP +/- buttons to set the desired delay time (e.g., 1-24 hours).
- The timer indicator will light up. The unit will turn on/off after the set time.
5.4 Sleep Mode
Sleep mode provides a comfortable sleeping environment by gradually adjusting the temperature and reducing fan noise.
- Press the SLEEP button while in Cooling mode.
- The temperature will increase by 1°C after the first hour and another 1°C after the second hour.
- The fan speed will automatically adjust to low.
5.5 Auto Restart
In case of a power outage, the unit will automatically restart with the last settings once power is restored.
6. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner.
6.1 Cleaning the Air Filter
The air filter should be cleaned every two weeks or more frequently depending on usage and air quality.
- Turn off the unit and unplug it from the power outlet.
- Locate the air filter panel (usually on the side or back).
- Remove the filter.
- Clean the filter with a vacuum cleaner or wash it with warm water (below 40°C) and mild detergent.
- Rinse thoroughly and allow it to air dry completely before reinstalling.
6.2 Draining Water
The unit has an internal water collection tank. When full, the unit will stop operating and display an error code (e.g., 'FL').
- Turn off the unit and unplug it.
- Place a shallow pan or tray under the drainage port at the bottom rear of the unit.
- Remove the drain plug. Water will flow out.
- Once drained, replace the drain plug securely.
For continuous drainage in Dehumidifying mode, connect a drain hose (not included) to the continuous drainage port.
6.3 Storage
If storing the unit for an extended period:
- Drain all accumulated water.
- Clean the air filter.
- Run the unit in Fan mode for a few hours to dry the internal components.
- Unplug the power cord and wrap it.
- Store the unit in a dry, cool place, preferably in its original packaging.
7. Troubleshooting
Before contacting customer support, refer to the following table for common issues and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power; Power cord not plugged in; Circuit breaker tripped. | Check power supply; Plug in firmly; Reset circuit breaker. |
| Unit not cooling effectively. | Air filter dirty; Exhaust hose blocked/disconnected; Room too large; Doors/windows open. | Clean air filter; Check hose connection; Ensure proper room size; Close doors/windows. |
| Unit is noisy. | Unit not on a level surface; Air filter dirty; Foreign object in fan. | Place on level surface; Clean air filter; Check for obstructions. |
| Water leakage. | Drain plug loose; Unit tilted; Continuous drain hose blocked. | Secure drain plug; Place on level surface; Clear drain hose. |
| Display shows 'FL' (Full Water). | Water tank is full. | Drain the water from the unit. |
8. Technical Specifications
| Specification | Value |
|---|---|
| Model Number | GPC09AM-K5NNA1A |
| Cooling Capacity | 9000 BTU / 2.6 KW |
| Power Consumption | 1000 Watt |
| Voltage | 230 Volt |
| Energy Efficiency Class | A |
| Refrigerant | R290 |
| Product Dimensions (D x W x H) | 35.8 x 30.4 x 80.5 cm |
| Weight | 27 Kilograms |
| Special Features | Dehumidifier, Automatic Cleaning |
| Included in Delivery | Mobile Air Conditioner, Remote Control, Exhaust Hose, Easy-rolling Casters, Operating Manual |
9. Warranty and Customer Support
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact GREE customer service directly. Keep your purchase receipt as proof of purchase.
For further assistance, please visit the official GREE website or contact your local dealer.
Ask a question about this manual