SINOTIMER TM616
TM616 Weekly Programmable Timer
Digital Time Switch Relay Control User Manual
Model: TM616 | Brand: SINOTIMER
1. Introduction
The SINOTIMER TM616 is a versatile weekly programmable digital timer switch designed for precise control of electrical equipment. It allows users to set specific ON/OFF times for various devices over a 24-hour or 7-day cycle, making it ideal for automating household appliances, lighting, and other electrical systems within DB boards.
Equipped with a built-in battery, the TM616 retains programmed settings during power outages, ensuring reliable operation. Its robust design and high capacity make it suitable for a wide range of applications requiring automated power management.
2. Key Features and Characteristics
- Programmable Control: Allows switching ON/OFF electrical equipment at preset times.
- High Capacity: Supports up to 6500 Watts / 30 Amps, suitable for various loads.
- Flexible Scheduling: 24 hours / 7 days a week programmable with 17 ON/OFF settings.
- Memory Backup: Built-in 1.2V 40Ma rechargeable battery preserves programs during power failure for up to 60 days.
- Accuracy: Auto time error correction of +/- 30 seconds weekly.
- Manual Override: Option to manually set ON/OFF.
- Minimum Interval: Programs can be set with a minimum interval of 1 minute.
- Wide Timer Range: From 1 minute to 168 hours.
3. Product Overview
Familiarize yourself with the components and layout of the TM616 timer.

Figure 3.1: Front View of TM616 Timer. This image displays the front panel of the TM616 timer, showing the digital LCD screen, control buttons (Clock, TIMER, C/R, Manual, Week, Hour, Minute), and the SINOTIMER brand logo.

Figure 3.2: Angled View with Wiring Diagram. This image shows an angled view of the TM616 timer, highlighting the side label which includes the model number (TM-616), working voltage (220V AC), output control (30A), and a basic wiring diagram for connection.

Figure 3.3: Bottom View with DIN Rail Mount. This image illustrates the bottom of the TM616 timer, clearly showing the yellow clip mechanism designed for easy installation onto a standard DIN rail.
4. Technical Specifications
| Parameter | Value |
|---|---|
| Model Number | TM616 |
| Brand | SINOTIMER |
| Voltage Options | AC 110V/220V, DC 12V (model specific) |
| Capacity | 30(16)A 250V AC (6500 Watts / 30 Amps) |
| Programs | 17 ON/OFF settings per day or week |
| Minimum Interval | 1 minute |
| Timer Range | 1 minute to 168 hours |
| Rechargeable Battery | 1.2V 40Ma (for memory backup) |
| Average Error | +/- 1 second / 24 hours (at 25°C) |
| Temperature Range | -20°C to +50°C |
| Black-out Memory | Up to 60 days |
| Material | Resin, Plastic |
| Color | Black |
| Screen Size | 1.5 Inches |
| Item Weight | 7 ounces |
| Package Dimensions | 6.46 x 6.42 x 4.06 inches |
5. Installation and Setup
Important: Installation should only be performed by a qualified electrician to ensure safety and compliance with local electrical codes. Disconnect power before installation.
5.1 DIN Rail Mounting
- Ensure the power supply to the circuit is completely off.
- Locate a standard 35mm DIN rail within your electrical panel or enclosure.
- Align the TM616 timer with the DIN rail. The yellow clip on the bottom (refer to Figure 3.3) should engage with the rail.
- Press the timer firmly onto the DIN rail until it clicks securely into place.
5.2 Wiring Connections
Refer to the wiring diagram on the side of the unit (Figure 3.2) and the specific voltage model (110V, 220V, or 12V) for correct connections. The TM616 typically has terminals for power input (L, N) and load output (NO, NC, COM for relay contacts).
- Connect the incoming Live (L) and Neutral (N) wires to the designated power input terminals of the timer.
- Connect the Live wire from your load (e.g., light, appliance) to the Normally Open (NO) terminal of the timer's relay.
- Connect the Common (COM) terminal of the timer's relay to the Live wire of your power supply.
- Ensure all connections are tight and secure.
Note: The specific wiring configuration may vary slightly depending on whether you are using the Normally Open (NO) or Normally Closed (NC) contact for your application. Always consult the diagram on the device and local electrical standards.
5.3 Initial Power-Up
After wiring, restore power to the circuit. The timer's LCD display should illuminate. If the display is blank, check power connections.
Upon first power-up or after a prolonged power outage, the internal battery may need to charge for a few minutes before full functionality is available. The display might show "OFF" or a default time.
6. Operating Instructions
6.1 Setting Current Time and Day
- Press the "Clock" button and hold it.
- While holding "Clock", press "Week" to set the current day of the week (MO, TU, WE, TH, FR, SA, SU).
- While holding "Clock", press "Hour" to set the current hour.
- While holding "Clock", press "Minute" to set the current minute.
- Release the "Clock" button. The time is now set.
6.2 Programming ON/OFF Events (17 Settings)
The TM616 allows for up to 17 ON/OFF program settings. Each program consists of an ON time and an OFF time.
- Press the "TIMER" button once. The display will show "1 ON" and the time will flash.
- Press "Week" to select the day(s) for this program (e.g., everyday, weekdays, weekends, specific days).
- Press "Hour" to set the desired ON hour.
- Press "Minute" to set the desired ON minute.
- Press "TIMER" again. The display will show "1 OFF" and the time will flash.
- Repeat steps 2-4 to set the desired OFF day(s), hour, and minute for this program.
- Press "TIMER" again to move to the next program setting (e.g., "2 ON"). Repeat the process for up to 17 ON/OFF programs.
- To exit programming mode and save settings, press the "Clock" button at any time.
Tip: If you need to clear a specific program, press the "C/R" button while viewing that program setting. This will reset the time to "--:--".
6.3 Manual Override
The "Manual" button allows you to override the programmed settings temporarily or permanently.
- Press "Manual" repeatedly to cycle through the modes:
- ON AUTO: The timer is currently ON and will follow the programmed schedule.
- OFF AUTO: The timer is currently OFF and will follow the programmed schedule.
- ON: The timer output is forced ON, overriding all programs.
- OFF: The timer output is forced OFF, overriding all programs.
- Select "ON AUTO" or "OFF AUTO" to resume normal programmed operation.
7. Maintenance
- Cleaning: Wipe the timer's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Battery: The internal rechargeable battery is designed for long life and typically does not require replacement. It charges automatically when the timer is connected to power. If the display is consistently blank or loses time rapidly after power outages, the battery may be depleted or at the end of its life.
- Environment: Ensure the timer is installed in a dry environment, free from excessive dust, moisture, and extreme temperatures, within the specified operating range (-20°C to +50°C).
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Display is blank or dim. | No power supply; internal battery depleted. | Check power connections. Allow timer to charge for 10-15 minutes after connecting to power. |
| Timer does not turn ON/OFF at programmed times. | Incorrect programming; manual override active; wiring issue. |
|
| Time is inaccurate. | Initial setting error; extreme temperature. | Reset the current time and day (Section 6.1). The timer has an auto-correction feature, but significant deviations might indicate environmental factors. |
| Programs are lost after power outage. | Internal battery is not holding charge. | The internal battery may be at the end of its life. While not user-replaceable, ensure the unit is consistently powered to allow the battery to charge. |
9. Warranty and Support
SINOTIMER products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation provided at the time of purchase or contact your retailer. In case of technical issues or support inquiries, please reach out to the SINOTIMER customer service or your product supplier.
Please have your product model number (TM616) and purchase details ready when contacting support.
Ask a question about this manual