1. Introduction
The Fantech HERO150H is a Heat Recovery Ventilator (HRV) designed to provide continuous fresh air to your home while recovering heat from outgoing stale air. This appliance is crucial for maintaining indoor air quality in well-sealed modern homes by removing excess moisture, odors, and contaminants. It works by continuously supplying up to 160 CFM (Cubic Feet per Minute) of fresh, filtered air and simultaneously removing an equal amount of moist, stale air.
The HERO150H features an energy-efficient counterflow core that recovers up to 80% of the heat from the exhaust air, transferring it to the incoming fresh air. During warmer months, this process helps to cool the incoming air, reducing the load on your air conditioning system. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Fantech HERO150H unit.
2. Safety Information
Please read all instructions carefully before installing or operating the Fantech HERO150H. Failure to follow these instructions may result in property damage, personal injury, or death.
- Always disconnect power to the unit before performing any maintenance or service.
- Installation and servicing must be performed by qualified personnel in accordance with all local codes and regulations.
- Ensure proper grounding of the unit to prevent electrical shock.
- Do not operate the unit with damaged wiring or components.
- Keep all foreign objects out of the air inlets and outlets.
- This product may contain materials cautioned by California Proposition 65.
3. Setup and Installation
The Fantech HERO150H is designed for straightforward installation, featuring a wall mount, external electrical box, and easy-connect ports. Professional installation is recommended.
3.1 Mounting the Unit
The unit comes with a wall mount for secure installation. Choose a location that allows for easy access for maintenance and duct connections. Ensure the mounting surface is capable of supporting the unit's weight (approximately 1 pound / 0.45 kg, but consider full operational weight with ducts).
3.2 Duct Connections
The HERO150H features 6-inch top-mounted duct connections with plastic collar shrouds and integrated backdraft dampers. Connect the appropriate supply and exhaust ducts to these ports. Ensure all ductwork is properly sealed to prevent air leakage and optimize performance.
3.3 Electrical Connection
Connect the unit to a suitable power source via the external electrical box. The unit operates on 120V and has a wattage of 3.6 watts. All electrical wiring must comply with local electrical codes. The unit is compatible with the ECO-TOUCH Programmable Wall Control for advanced operation.

4. Operating Instructions
The Fantech HERO150H is designed for continuous operation to ensure optimal indoor air quality. Once properly installed and powered, the unit will begin to exchange air between the indoors and outdoors.
4.1 Control Method
The unit's primary control method is via a compatible wall control, such as the ECO-TOUCH Programmable Wall Control. This allows for precise adjustment of ventilation rates and scheduling. Refer to the wall control's specific manual for detailed programming and operation instructions.
4.2 Airflow
The HERO150H provides up to 160 CFM of balanced fresh air supply and stale air exhaust. Integrated in-door manometer ports allow for easy airflow verification during commissioning or maintenance.
5. Maintenance
Regular maintenance ensures the longevity and efficient operation of your Fantech HERO150H. Always disconnect power before performing any maintenance.
5.1 Filter Replacement
The unit includes an integrated MERV8 fresh air filter. This filter should be inspected every 3 months and replaced every 6-12 months, or more frequently depending on air quality and usage. A dirty filter can reduce airflow and efficiency.
- Open the front access panel.
- Locate and remove the MERV8 filter.
- Insert a new, clean MERV8 filter, ensuring it is properly seated.
- Close the front access panel securely.
5.2 Heat Recovery Core Cleaning
The counterflow core should be cleaned annually to maintain heat transfer efficiency. Refer to the detailed cleaning instructions in the full product manual available from Fantech.
6. Troubleshooting
This section provides solutions to common issues you might encounter with your HERO150H. For more complex problems, contact qualified service personnel.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit not operating | No power supply; tripped circuit breaker; faulty wiring. | Check power connection; reset circuit breaker; inspect wiring (by qualified personnel). |
| Reduced airflow | Dirty air filter; blocked ducts; dirty heat recovery core. | Replace air filter; check ducts for obstructions; clean heat recovery core. |
| Unusual noise | Loose components; motor issue; fan obstruction. | Inspect for loose parts; contact service technician if motor or fan issue is suspected. |
| Excessive condensation | Improper drainage; extreme humidity. | Check and clear condensate drain; ensure proper insulation of ducts in unconditioned spaces. |
7. Specifications
Detailed technical specifications for the Fantech HERO150H Fresh Air Appliance.
| Feature | Specification |
|---|---|
| Model Number | HERO150H |
| Airflow Capacity | Up to 160 CFM |
| Duct Connections | 6-inch Top-Mounted |
| Filter Type | Integrated MERV8 Fresh Air Filter |
| Heat Recovery Core | Energy-efficient Counterflow |
| Power Source | Corded Electric |
| Wattage | 3.6 watts |
| Control Method | Touch (via compatible wall control) |
| Product Dimensions | 71.12 x 35.56 x 63.5 cm (28 x 14 x 25 inches); 15.2D x 15.2W x 15.2H Centimetres (6D x 6W x 6H inches) |
| Item Weight | 1 Pound (0.45 kg) |
| Manufacturer | Fantech |
| First Available | March 5, 2021 |
| EU Spare Part Availability | 5 Years |
8. Warranty and Support
For warranty information and technical support, please refer to the documentation included with your product or visit the official Fantech website. Keep your proof of purchase for warranty claims.
For further assistance, you may contact Fantech customer service directly. Ensure you have your model number (HERO150H) and purchase date available when contacting support.





