Innovair EIN10H2V32

Innovair Air Conditioner Inverter Ductless Wall Mount Mini Split System Hyper Heat Pump

Model: EIN10H2V32

Product Overview

The Innovair Inverter Ductless Wall Mount Mini Split System is a high-efficiency solution for both cooling and heating. Designed for optimal performance, it features advanced technology to maintain comfortable indoor temperatures while minimizing energy consumption.

Innovair Mini Split System: Indoor unit, outdoor unit, remote, and connection lines

Figure 1: Components of the Innovair Mini Split System, including the indoor unit, outdoor unit, remote control, and connection lines.

Setup and Installation

Proper installation is crucial for the optimal performance and longevity of your Innovair Mini Split System. It is recommended that installation be performed by a qualified HVAC professional.

Unboxing and Component Identification

Carefully unbox all components. Ensure all parts listed in the packing list are present and undamaged. The indoor unit contains the mounting bracket, copper lines, and drain line.

Innovair Indoor Unit Front View

Figure 2: Front view of the Innovair indoor unit, showcasing its sleek design.

Innovair Outdoor Unit

Figure 3: The outdoor condenser unit of the Innovair Mini Split System.

Line Evacuation and Refrigerant Release

Before releasing refrigerant, the lines must be properly evacuated to remove all air and moisture. This process typically involves using a vacuum pump for at least 15 minutes. After evacuation, seal the vacuum and monitor the pressure for approximately 15 minutes to ensure no leaks are present. Once confirmed, the refrigerant can be safely released into the system.

Innovair Mini Split System with Electric Bill graphic

Figure 4: Illustrates the high efficiency of the Innovair system, contributing to lower electric bills.

Operating Instructions

Your Innovair Mini Split System offers various modes and features for customized comfort.

Basic Operation

Use the provided remote control to power on the unit and set your desired temperature. The display on the indoor unit will show the current temperature setting.

Innovair Remote Control

Figure 5: The Innovair remote control for adjusting settings.

Advanced Features

Maintenance

Regular maintenance ensures the efficiency and longevity of your Innovair Mini Split System.

Filter Cleaning

The indoor unit is equipped with a high-density filter. For optimal air quality and system performance, clean the air filter regularly. Refer to the detailed instructions in the full user manual for specific cleaning procedures and frequency.

Outdoor Unit Care

Keep the area around the outdoor condenser unit clear of debris, leaves, and other obstructions to ensure proper airflow. The Gold-Fin coating on the outdoor condenser provides enhanced corrosion resistance.

Troubleshooting

This section provides basic troubleshooting tips for common issues. For more complex problems, contact a certified technician.

Unit Not Turning On

Insufficient Cooling/Heating

Specifications

AttributeValue
Brand NameInnovair
Product Dimensions9 x 38 x 12 inches
Efficiency (SEER)38.0
Capacity12000 British Thermal Units
Installation TypeSplit System
Part NumberEIN10H2V32
Form FactorMini-Split
Special FeaturesDefrost, Wifi
ColorWhite
Voltage230 Volts (AC)
Wattage2500 watts
RefrigerantR 410A
Innovair Mini Split Indoor Unit Dimensions

Figure 8: Dimensions of the Innovair indoor unit.

EnergyGuide Label for Innovair Mini Split System

Figure 9: EnergyGuide label detailing the cooling (SEER) and heating (HSPF) efficiency ratings.

Related Documents - EIN10H2V32

Preview Innovair Elite Heat Pump Ductless Splits Remote Controller Manual
This manual provides instructions for operating the Innovair Elite Heat Pump Ductless Splits remote controller. It covers features such as ON/OFF, fan speed control, mode selection, temperature adjustment, and special functions like I FEEL and SLEEP modes.
Preview Innovair Q Series Hyper Heat Outdoor Unit Installation Manual
Installation guide for the Innovair Q Series Hyper Heat Outdoor Unit, covering safety precautions, nomenclature, installation instructions, and electrical wiring diagrams for R454B refrigerant systems. Includes details on model number interpretation, operating temperature ranges, and essential safety warnings.
Preview Innovair Hyper Heat Condenser User and Installation Manual
Comprehensive guide for the installation and use of the Innovair Hyper Heat Condenser air conditioning unit. Covers safety precautions, installation procedures, refrigerant piping, wiring, and trial run.
Preview Innovair SLIM24 High Efficiency Heat Pump System: Installation and Owner's Manual
Comprehensive guide for installing and operating the Innovair SLIM24 High Efficiency Heat Pump System, covering safety precautions, maintenance, and troubleshooting for optimal performance.
Preview Innovair Single Zone Ductless Heat Pump Installation Manual
This manual provides detailed installation instructions for the Innovair Single Zone Ductless Heat Pump (Outdoor Unit), covering safety precautions, site preparation, installation steps, and wiring.
Preview Innovair SLIM4 SWV Series Indoor Unit User Manual
Comprehensive user manual for the Innovair SLIM4 SWV Series indoor air conditioning unit, covering safety precautions, operation, maintenance, and troubleshooting. Features include split system cooling and heat pump functionality with R454B refrigerant.