Texecom AKD-0001
Texecom AKD-0001 Capture Grade 2 Wired 20m Dual Tech PIR Sensor
User Manual
Introduction
This manual provides essential information for the proper installation, operation, and maintenance of your Texecom AKD-0001 Capture Grade 2 Wired 20m Dual Tech PIR Sensor. This advanced motion detector combines Passive Infrared (PIR) and Microwave (MW) technologies to provide reliable and accurate detection, minimizing false alarms. Please read this manual thoroughly before installation and keep it for future reference.
Safety Information
Always adhere to the following safety precautions to prevent injury or damage to the device:
- Installation should only be performed by qualified personnel in accordance with local electrical codes and regulations.
- Ensure power is disconnected before performing any wiring or maintenance.
- Do not expose the sensor to extreme temperatures, humidity, or direct water.
- Use only specified power sources (Corded Electric).
- Avoid placing the sensor near heat sources, direct sunlight, or strong air currents, which can cause false alarms.
Package Contents
Verify that all items are present in the package:
- Texecom AKD-0001 Capture Grade 2 Dual Tech PIR Sensor
- Mounting Screws and Wall Plugs
- Installation Template (if included)
- This User Manual
Product Overview
The Texecom AKD-0001 sensor is designed for robust indoor motion detection. It features a sleek white casing and a prominent spherical lens for optimal detection coverage.

Figure 1: Front view of the Texecom AKD-0001 PIR Sensor. The sensor is white with a large, clear, spherical detection lens in the center.

Figure 2: Side view of the Texecom AKD-0001 PIR Sensor, illustrating its compact design suitable for wall mounting.
Key Components:
- Detection Lens: The spherical lens is optimized for a 20-meter detection range.
- Status LED: (Location may vary) Indicates detection events and operational status.
- Terminal Block: For wired connections (power, alarm, tamper).
- Mounting Base: Designed for secure wall mounting.
Setup and Installation
Choosing a Location:
- Mount the sensor in a corner or on a flat wall at a height of 2.0 to 2.4 meters (6.5 to 8 feet) for optimal coverage.
- Avoid aiming the sensor directly at windows, heat sources (radiators, vents), or areas with significant air currents.
- Ensure the detection area is clear of large obstructions.
Mounting Steps:
- Prepare the Mounting Surface: Ensure the wall is clean and stable.
- Mark Drill Holes: Use the provided mounting template (if applicable) or the sensor's base to mark the screw positions on the wall.
- Drill Holes: Drill pilot holes for the mounting screws. Insert wall plugs if mounting into drywall or masonry.
- Route Wiring: Feed the necessary alarm system wiring through the opening in the sensor's backplate.
- Secure Base: Attach the sensor's mounting base to the wall using the provided screws.
- Wire Connections: Connect the power (12V DC), alarm, and tamper zone wires to the appropriate terminals on the sensor's PCB. Refer to your alarm panel's manual for specific wiring diagrams.
- Attach Sensor Body: Carefully clip or screw the main sensor body onto the mounted base, ensuring all wires are neatly tucked away and not pinched.
Operating the Sensor
The Texecom AKD-0001 is a passive device that detects motion by sensing changes in infrared radiation (PIR) and microwave reflections (MW). When both technologies detect movement simultaneously, an alarm signal is generated.
Walk Test:
After installation, perform a walk test to confirm the sensor's coverage and functionality:
- Power on the alarm system.
- Walk through the entire intended detection area, observing the sensor's status LED.
- The LED should illuminate when motion is detected.
- Adjust the sensor's position or sensitivity (if adjustable via jumpers/DIP switches, refer to specific product datasheet) until the desired coverage is achieved.
Note: The dual-tech nature of this sensor helps reduce false alarms by requiring confirmation from both PIR and Microwave elements before triggering an alarm.
Maintenance
The Texecom AKD-0001 sensor requires minimal maintenance to ensure optimal performance.
- Cleaning: Periodically wipe the sensor's lens and casing with a soft, dry, lint-free cloth. Do not use abrasive cleaners or solvents.
- Obstruction Check: Regularly check that no objects (e.g., furniture, plants) are obstructing the sensor's field of view.
- Functionality Test: Perform a walk test annually or as recommended by your alarm system provider to ensure continued proper operation.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Sensor not detecting motion | Incorrect wiring; Power issue; Obstructed view; Sensor fault. | Check wiring connections; Verify power supply; Clear obstructions; Perform walk test; Contact support if fault persists. |
| False alarms | Heat sources; Air currents; Direct sunlight; Pets; Incorrect sensitivity settings. | Relocate sensor away from heat/air sources; Ensure no direct sunlight; Consider pet-immune models if pets are an issue; Adjust sensitivity if possible. |
| LED not illuminating | Power issue; LED disabled (if configurable); Sensor fault. | Check power; Consult alarm panel manual for LED settings; Contact support. |
Specifications
| Feature | Detail |
|---|---|
| Model | AKD-0001 |
| Brand | Texecom |
| Detection Technology | Dual Tech (PIR & Microwave) |
| Maximum Range | 20 Metres |
| Power Source | Corded Electric (typically 9-15V DC) |
| Mounting Type | Wall Mount |
| Colour | White |
| Grade | Grade 2 |
Warranty and Support
Texecom products are manufactured to high standards and are typically covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Texecom website.
For technical support, troubleshooting assistance beyond this manual, or warranty claims, please contact your authorized Texecom installer or distributor. You may also find additional resources and contact information on the official Texecom website: www.texecom.com
Ask a question about this manual