1. Introduction

This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of the Uponor Vario M Flow Meter Manifold, Model 1085950. Please read this manual thoroughly before installation and keep it for future reference. This product is designed for use in heating systems, particularly underfloor heating applications.

2. Safety Information

3. Product Overview

The Uponor Vario M Flow Meter Manifold (Model 1085950) is an 8-output collector designed for precise control and distribution of heating water in underfloor heating systems. It features integrated flow meters for each circuit, allowing for individual flow adjustment and monitoring.

Uponor Vario M Flow Meter Manifold

Image showing the Uponor Vario M Flow Meter Manifold with 8 outlets, featuring flow meters on the top bar and connection points below.

Components:

4. Setup and Installation

  1. Mounting: Securely attach the manifold to a suitable wall or mounting surface using the provided brackets. Ensure it is level and easily accessible for connections and adjustments.
  2. Main Connection: Connect the main supply and return lines to the G1 connections on the manifold. Ensure a tight seal using the provided gasket. The manifold supports both right and left main connections.
  3. Circuit Connections: Connect the individual heating circuits to the 8 G3/4" Eurocone threaded outlets. Use appropriate fittings and ensure all connections are leak-free. The circuit separation is 50 mm.
  4. Flushing and Filling: Before commissioning, flush the system thoroughly to remove air and debris. Fill the system with water and vent any remaining air.
  5. Pressure Test: Perform a pressure test according to local regulations to ensure system integrity.

5. Operating Instructions

  1. Flow Adjustment: Each circuit is equipped with an integrated flow meter. To adjust the flow rate for a specific circuit, rotate the adjustment cap on the flow meter until the desired flow (indicated in liters per minute) is achieved.
  2. Temperature Monitoring: The integrated thermometers provide a visual indication of the supply and return temperatures.
  3. System Balancing: Adjust the flow meters on each circuit to balance the heating system, ensuring even heat distribution across all zones.

6. Maintenance

7. Troubleshooting

ProblemPossible CauseSolution
No flow or low flow in a circuitAir in the circuit, closed valve, clogged flow meter, pump issueBleed air from the circuit, check valve position, inspect/clean flow meter, check pump operation.
Leakage at connectionsLoose connection, damaged gasket/seal, incorrect fittingTighten connections, replace damaged gaskets/seals, ensure correct fittings are used.
Inconsistent heating across zonesSystem imbalance, air in circuitsAdjust flow meters to balance the system, bleed air from all circuits.

8. Specifications

FeatureDetail
Model Number1085950
ManufacturerUponor
Number of Outputs8
Circuit ConnectionsG3/4" Eurocone male thread
Main ConnectionG1 (right or left, with sealing gasket)
Circuit Separation50 mm
MaterialReinforced Polyamide (UNE-EN-1264)
Nominal Pressure6 bar
Max Operating Temperature60 °C
Dimensions (L x W x H)51 cm x 5 cm x 25 cm
Weight3 kg
ColorBlack

9. Warranty and Support

Uponor products are manufactured to high-quality standards. For warranty information, please refer to the specific warranty terms provided with your purchase or visit the official Uponor website. For technical support, spare parts, or service inquiries, please contact your local Uponor distributor or customer service representative. Always provide the model number (1085950) when seeking support.

Related Documents - 1085950

Preview Uponor Classic Installation Manual
This manual provides detailed installation instructions for the Uponor Classic system, including pipe laying, manifold connection, and pressure testing. It covers essential steps for a successful and efficient installation of the Uponor Classic floor heating system.
Preview Uponor Vario Cabinets: Technical Information, Specifications, and Installation Guide
Comprehensive technical information for Uponor Vario cabinets, including system description, planning, configuration, installation, operation, and detailed dimensions for in-wall (IW) and on-wall (OW) models, as well as manifold compatibility.
Preview Uponor Nubos Installation Guide: Manifold Systems & Underfloor Heating Pipes
Detailed installation manual for the Uponor Nubos underfloor heating system. Covers manifold setup, pipe installation (Comfort Pipe PLUS, Smart UFH-pipe, MLCP RED), and system testing. Includes diagrams and technical specifications.
Preview Uponor Renovis Installation Manual
Comprehensive installation manual for the Uponor Renovis system, detailing components, assembly, and technical specifications for underfloor heating installations. Includes diagrams and step-by-step instructions.
Preview Uponor Underfloor Heating and Cooling: Planning Information Guide
This comprehensive planning guide from Uponor details underfloor heating and cooling systems, covering technical specifications, design criteria, installation procedures, and hydraulic balancing for optimal climate control solutions.
Preview Uponor Vario / Vario PLUS Actuator Installation and Technical Manual
Comprehensive guide to the Uponor Vario and Vario PLUS actuators, covering installation, operation, features like 'First-Open', and detailed technical specifications for HVAC systems.