Introduction
The COLLOMIX AQiX Water Dosing Device is engineered for precise water metering in various material mixing applications. This device ensures accurate water quantities, which is crucial for achieving consistent material properties and optimal performance, thereby eliminating manual guesswork.
Safety Instructions
- Read this instruction manual completely before operating the device.
- Ensure all connections are secure before use to prevent leaks.
- Do not expose the device to freezing temperatures. Drain all water before storing in cold conditions.
- Keep the device dry and clean. Avoid submerging the device in water.
- Use only with clean water. Do not use with corrosive liquids or chemicals.
- Always disconnect the device from the water supply when not in use.
- Keep out of reach of children.
Package Contents
Verify that all items are present in the package:
- COLLOMIX AQiX Water Dosing Device
- Sturdy hard shell case
- 1/2" connector adapter
- 2x AA batteries
Setup
Battery Installation
- Locate the battery compartment on the device.
- Open the compartment cover.
- Insert the two AA batteries, ensuring correct polarity (+/-).
- Close the battery compartment cover securely.
Connecting to Water Supply
- Attach the 3/4" quick connect hose adapter to your water hose.
- Connect the AQiX device to the quick connect hose adapter. Ensure a tight and leak-free connection.
- The device can be held manually or rested on the edge of a mixing bucket using its integrated support.

Image: The COLLOMIX AQiX device shown connecting to a standard garden hose using its 3/4-inch quick connector for easy setup.

Image: The COLLOMIX AQiX device positioned with its integrated support resting on the rim of a mixing bucket, ready for water dispensing.
Operating Instructions
Powering On/Off
Press the power button (usually the central 'Play/Pause' button) to turn the device on. The display will illuminate. To turn off, press and hold the power button.
Setting Water Volume
- Use the '+' and '-' buttons to adjust the desired water volume. The display will show the set amount.
- The device supports measurements in various units (e.g., liters, gallons, fluid ounces). Refer to the display for the current unit.
Memory Functions (m1, m2)
The AQiX device features two memory buttons (m1, m2) to store frequently used water volumes.
- To Save: Set the desired water volume using '+' and '-' buttons. Press and hold either 'm1' or 'm2' until the display confirms the setting is saved.
- To Recall: Briefly press 'm1' or 'm2' to load the saved water volume.
Dispensing Water
- Once the desired water volume is set (either manually or recalled from memory), position the device over your mixing container.
- Press the 'Play/Pause' button to start the water flow.
- The device will automatically stop the water flow once the programmed volume has been dispensed.
- To pause or manually stop the flow before the set volume is reached, press the 'Play/Pause' button again.

Image: A user holding the COLLOMIX AQiX device, dispensing a precise amount of water into a black mixing bucket for material preparation.

Image: A close-up view of the COLLOMIX AQiX device in operation, accurately dispensing water into a bucket, with the digital display showing the current measurement.

Image: The COLLOMIX AQiX device being used alongside a large material mixer, demonstrating its integration into professional mixing workflows.
Manual Mode
For continuous flow or to override programmed settings, press the 'man' button. The device will dispense water as long as the 'Play/Pause' button is held down. Release the button to stop the flow.
Maintenance
Cleaning
- After each use, rinse the device with clean water to remove any material residue.
- Wipe the exterior with a damp cloth. Do not use abrasive cleaners or solvents.
- Ensure the display and buttons are free from dirt and debris.
Storage
- Store the AQiX device in its sturdy hard shell case to protect it from damage.
- Keep the device in a dry, frost-free environment.
- For long-term storage, remove the AA batteries to prevent leakage.
Troubleshooting
- Device does not power on: Check if the AA batteries are correctly installed and have sufficient charge. Replace if necessary.
- Inaccurate water measurement: Ensure the device is properly connected to the water supply and there are no blockages in the flow path. Verify that the water pressure is within the recommended operating range.
- Water leakage: Inspect all hose connections for tightness. Check the quick connect adapter for proper seating and any damage.
- Water flow stops prematurely or does not start: Ensure the set volume is not zero. Check for kinks in the hose or insufficient water pressure.
Specifications
| Feature | Detail |
|---|---|
| Product Dimensions | 12"L x 11"W x 6"H (12 x 11 x 6 inches) |
| Item Model Number | AQiX |
| Batteries | 2 AA batteries (included) |
| Manufacturer | Collomix |
| Material | Stainless Steel |
| Item Weight | 1.5 Pounds |
| Maximum Flow Rate | 10.5 Gallons Per Minute |
| Maximum Lifting Height | 1 Meter |
| Voltage | 12 Volts (DC) |
Warranty and Support
For warranty information, technical support, or service inquiries, please contact Collomix customer service. Refer to the official Collomix website or product packaging for the most current contact details.