Introduction
Welcome to your new Gevril Yorkville Swiss Automatic Watch, Model 48601. This manual provides essential information for the proper setup, operation, and maintenance of your timepiece. Adhering to these instructions will help ensure the longevity and optimal performance of your watch.
The Gevril Yorkville collection is renowned for its blend of classic design and Swiss automatic movement, offering reliability and precision. Your watch is a testament to fine Swiss watchmaking.

Image: Front view of the Gevril Yorkville 48601 watch, showcasing its blue dial, prominent markers, and stainless steel bracelet.
Key Features
- 43mm Stainless Steel Case: A robust and confident case size, crafted from high-quality stainless steel.
- Unique Blue/Black Dial: Features a distinctive dial color that enhances readability and aesthetic appeal.
- 316L Stainless Steel Construction: Ensures durability and corrosion resistance for both the case and bracelet.
- Swiss Automatic Movement (Sellita SW200): A reliable and precise self-winding mechanical movement, eliminating the need for a battery.
- Diver's Watch: Designed with features suitable for diving, indicating enhanced water resistance.
- Date Display: Conveniently located at the 3 o'clock position.
- Prominent Time Markers: Large, luminous markers ensure excellent visibility in various lighting conditions.
Initial Setup
Winding the Watch
Your Gevril Yorkville watch is equipped with a Swiss automatic movement, which is powered by the natural motion of your wrist. If the watch has stopped or is running low on power, it needs to be manually wound to initiate operation.
- Unscrew the Crown: Locate the crown on the right side of the watch case. If it is a screw-down crown, turn it counter-clockwise until it springs free.
- Pull to Position 1: Gently pull the crown out to position 1 (the first click).
- Manual Winding: Turn the crown clockwise approximately 30-40 times. This action will fully wind the mainspring, providing sufficient power reserve.
- Secure the Crown: Push the crown back into position 0 and screw it down tightly by turning it clockwise. This ensures the watch's water resistance.
Note: The watch will continue to run as long as it is worn regularly. If unworn, it typically has a power reserve of approximately 38-42 hours.
Setting the Time
- Unscrew and Pull Crown: Unscrew the crown (if applicable) and pull it out to position 2 (the second click). The second hand will stop.
- Set Time: Turn the crown clockwise or counter-clockwise to set the desired time. To avoid confusion between AM/PM for the date change, it is recommended to advance the hands past 12 o'clock until the date changes, then set the correct time.
- Secure the Crown: Once the time is set, push the crown back into position 0 and screw it down securely to maintain water resistance.

Image: Side view of the Gevril Yorkville 48601 watch, highlighting the screw-down crown mechanism.
Operation
Setting the Date
The date display is conveniently located at the 3 o'clock position on your watch.
- Unscrew and Pull Crown: Unscrew the crown (if applicable) and gently pull it out to position 1 (the first click).
- Adjust Date: Turn the crown counter-clockwise to adjust the date.
- Secure the Crown: Once the correct date is displayed, push the crown back into position 0 and screw it down securely.
Important: Avoid setting the date between 9 PM and 3 AM. During this period, the watch's internal date change mechanism is engaged, and manual adjustment can cause damage. If you need to set the date during these hours, first set the time outside this window (e.g., to 6 AM), then set the date, and finally reset the time to the current time.
Using the Unidirectional Bezel
Your Gevril Yorkville watch features a unidirectional rotating bezel, a common tool for timing events, particularly useful for divers.
- Align Marker: Rotate the bezel counter-clockwise to align the triangle marker (or zero marker) with the minute hand.
- Read Elapsed Time: As time passes, the minute hand will indicate the elapsed time on the bezel's scale.
- Safety Feature: The unidirectional design ensures that if the bezel is accidentally bumped, it will only rotate in a direction that indicates a longer elapsed time, preventing underestimation of timed durations.
Care and Maintenance
Cleaning
To maintain the aesthetic appeal and hygiene of your watch, clean the case and bracelet regularly. Use a soft, damp cloth for general cleaning. For stainless steel bracelets, a soft brush with mild soap and water can be used, followed by thorough rinsing with clean water and careful drying with a soft cloth.
Water Resistance
The Gevril Yorkville 48601 is designed as a diver's watch, offering enhanced water resistance. To ensure this protection, always make sure the crown is screwed down tightly after any adjustments. Avoid operating the crown or any other pushers (if present) while the watch is submerged in water or wet, as this can compromise the water resistance.
Storage
When not wearing your watch, store it in a cool, dry place, away from direct sunlight, extreme temperatures, and strong magnetic fields. For extended periods of non-wear, consider using a watch winder to keep the automatic movement running and lubricated, reducing the need for frequent manual winding.
Service
For optimal performance and longevity, it is recommended to have your automatic watch serviced by an authorized Gevril service center every 3-5 years. Regular servicing ensures the movement remains clean, lubricated, and accurate.
Troubleshooting
Watch Not Running or Stopping
- Solution: Your automatic watch requires motion to power its movement. If it has stopped, it likely needs to be manually wound. Refer to the "Winding the Watch" section. Ensure it is worn regularly or kept on a watch winder to maintain its power reserve.
Date Not Changing Correctly
- Solution: Check if the date was set during the prohibited hours (9 PM - 3 AM). If so, carefully reset the time and date following the instructions in the "Setting the Date" section. Ensure the crown is fully pulled out to position 1 for date adjustment.
Condensation Under Crystal
- Solution: Small amounts of condensation that disappear quickly are usually not a concern. However, persistent condensation indicates a potential breach in water resistance. Contact Gevril customer support or an authorized service center immediately to prevent further damage.
For any issues not covered in this section, please contact Gevril customer support for assistance.
Product Specifications
| Feature | Detail |
|---|---|
| Model Number | 48601 |
| Movement | Swiss Automatic (Sellita SW200) |
| Case Material | 316L Stainless Steel |
| Case Diameter | 43mm |
| Dial Color | Blue/Black |
| Water Resistance | Diver's (200 Meters / 660 Feet) |
| Date Display | Yes, at 3 o'clock |
| Bezel | Unidirectional Rotating |
| Manufacturer | Gevril |
| Date First Available | March 4, 2021 |
| Package Dimensions | 8.03 x 6.38 x 5.31 inches |
| Item Weight | 3.15 Pounds |

Image: Rear view of the Gevril Yorkville 48601 watch, displaying the transparent case back that reveals the intricate Swiss automatic movement.
Warranty and Customer Support
Warranty Information
Gevril watches typically come with a manufacturer's warranty covering defects in materials and workmanship. Please refer to the warranty card included with your purchase for specific terms, conditions, and duration. It is important to retain your proof of purchase for any warranty claims.
Customer Support
For service, repairs, or any questions regarding your Gevril Yorkville watch, please visit the official Gevril website or contact an authorized Gevril service center. Their expert team can provide specialized assistance.
You can also visit the Gevril Store on Amazon for additional product information and resources.

