Introduction

Thank you for choosing the COLZER CD190S Commercial Dehumidifier. This powerful unit is designed to efficiently remove excess moisture from large areas up to 7,000 square feet, making it ideal for basements, building sites, warehouses, and water damage restoration. Featuring a robust compressor, built-in pump, and continuous drainage capability, the CD190S ensures a drier, healthier environment. Please read this manual thoroughly before operation to ensure proper use, maintenance, and safety.

Important Safety Instructions

WARNING: To reduce the risk of fire, electric shock, or injury, always follow basic safety precautions when operating this appliance.

  • Read all instructions before using the dehumidifier.
  • Ensure the power supply matches the voltage requirements of the unit.
  • Do not operate the unit with a damaged cord or plug.
  • Do not block air inlets or outlets. Maintain adequate clearance around the unit.
  • Always unplug the dehumidifier before cleaning or performing any maintenance.
  • Do not use the dehumidifier in areas where flammable liquids or gases are stored.
  • Keep children and pets away from the unit during operation.
  • Place the unit on a stable, level surface to prevent tipping.
  • Do not immerse the unit in water or other liquids.

Key Features

  • High Capacity: Removes up to 180 Pints (90 PPD AHAM) of moisture per day, covering areas up to 7,000 sq. ft.
  • Built-in Pump: Features an integrated heavy-duty pump for continuous drainage, eliminating the need for manual emptying.
  • Continuous Drainage: Comes with a 10 ft long drain hose for automatic and effortless water removal.
  • Easy Portability: Equipped with a rigid handle and 10-inch semi-pneumatic wheels for convenient movement across various surfaces.
  • User-Friendly Control Panel: Intuitive digital display for humidity setting, timer, auto defrost, and pump drain control.
  • Auto Defrost: Automatically prevents frost buildup on coils in low-temperature environments.
  • Auto Restart: The unit restarts automatically to previous settings after a power outage.
  • Durable Construction: Built with a robust plastic and metal casing for commercial use.
COLZER CD190S Commercial Dehumidifier with airflow illustration

Image: The COLZER CD190S Commercial Dehumidifier illustrating its powerful airflow and moisture removal capabilities.

Technical Specifications

AttributeDetail
Model NameCD190S
BrandCOLZER
Moisture Removal Capacity (Saturation)180 Pints/Day
Moisture Removal Capacity (AHAM)90 Pints/Day
Coverage AreaUp to 7,000 Sq. Ft
Airflow Rate324 CFM / 550 CMH
Power Source120V, 60Hz
Rated Power1150W, 10.3A
Drainage TypeBuilt-in Pump, Continuous Drainage
Pump Drain Height16 ft
Drain Hose Length10 ft
Power Cord Length8.6 ft
Product Dimensions (L x W x H)19.6 x 21.2 x 32.6 inches
Item Weight102.6 pounds
MaterialPlastic, Metal
ColorGreen
COLZER CD190S Dehumidifier with dimensions and performance specifications

Image: Detailed dimensions and performance specifications of the COLZER CD190S Dehumidifier.

Setup Guide

1. Unpacking and Placement

  1. Carefully remove the dehumidifier from its packaging. It is recommended to have two people for lifting due to its weight (102.6 lbs).
  2. Place the unit upright on a stable, level surface.
  3. Allow the unit to stand upright for at least 24 hours before plugging it in. This allows the refrigerant to settle.
  4. Ensure there is at least 12 inches (30 cm) of space around all sides of the unit for proper airflow.
COLZER CD190S Commercial Dehumidifier

Image: The COLZER CD190S Commercial Dehumidifier, ready for placement.

2. Power Connection

  • Unwind the 8.6 ft power cord from the cable management arm located at the back of the unit.
  • Plug the power cord into a grounded 120V, 60Hz electrical outlet.
COLZER CD190S Dehumidifier showing handle, wheels, and power cord winder

Image: The back of the dehumidifier showing the power cord winder and cable management arm.

3. Drainage Setup

The CD190S features a built-in pump for continuous drainage. This eliminates the need to manually empty a water tank.

  • Locate the drain hose connection point on the unit.
  • Connect the provided 10 ft drain hose to the unit's drainage outlet. Ensure a secure connection to prevent leaks.
  • Route the other end of the drain hose to a suitable drainage location, such as a floor drain, sink, or out a window. The built-in pump can lift water up to 16 feet vertically.
  • Ensure the hose is not kinked or obstructed, which could prevent proper drainage.
Diagram of COLZER CD190S Dehumidifier with built-in pump and drain hose

Image: Diagram illustrating the built-in heavy-duty pump and its drainage capabilities, including vertical drain height and hose length.

Video: This video demonstrates the features and operation of the COLZER Commercial Dehumidifier, including its setup and automatic drainage system.

Operating Instructions

Control Panel Overview

COLZER CD190S Dehumidifier control panel

Image: Close-up view of the easy-to-operate control panel with various function icons.

  • Power Button: Turns the unit ON or OFF.
  • Humidity Reading: The digital display shows the current ambient humidity level.
  • Up/Down Buttons: Used to adjust the desired humidity set-point (10-98% RH) or timer settings.
  • Timer Button: Press and hold for 3 seconds to enter timer setting mode (1-24 hours).
  • Pump Button: Manually activates the pump drain function.
  • Defrost Indicator: Illuminates when the auto defrost function is active.
  • Running Indicator: Illuminates when the dehumidifier is actively running.

Starting Operation

  1. Press the Power button to turn on the dehumidifier. The display will show the current room humidity.
  2. Use the Up or Down buttons to set your desired humidity level. The unit will operate until the set humidity is reached, then cycle off. It will restart when the humidity rises above the set level.
  3. For continuous operation, set the humidity level to 10% RH.

Timer Function

  1. To set a timer for automatic shut-off or turn-on, press and hold the Timer button for 3 seconds.
  2. Use the Up or Down buttons to select the desired number of hours (1-24).
  3. The timer indicator will illuminate, and the unit will automatically turn off or on after the set time.

Pump Drain Operation

The built-in pump automatically drains collected water. If you need to manually activate the pump, press the Pump button. The pump indicator will illuminate.

Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your COLZER dehumidifier.

1. Cleaning the Air Filter

  • The air filter should be cleaned every two weeks or more frequently depending on usage and air quality.
  • Turn off the dehumidifier and unplug it from the power outlet.
  • Locate the air filter on the back or side of the unit. Gently pull it out.
  • Wash the filter with warm, soapy water. Rinse thoroughly and allow it to air dry completely before reinserting. Do not use a dishwasher.
  • Reinsert the dry filter back into the unit.
COLZER CD190S Dehumidifier showing removable high-airflow filter

Image: Illustration of how to remove and clean the high-airflow filter.

2. Cleaning the Exterior

  • Wipe the exterior of the unit with a soft, damp cloth.
  • Do not use harsh chemicals, abrasive cleaners, or solvents, as these may damage the surface.

3. Long-Term Storage

  • If storing the unit for an extended period, ensure it is completely dry inside and out.
  • Clean the air filter and replace it.
  • Wrap the power cord neatly around the cable management arm.
  • Store the unit in an upright position in a cool, dry place, away from direct sunlight and extreme temperatures.

Troubleshooting Guide

ProblemPossible CauseSolution
Dehumidifier does not turn on.No power supply; Power cord not plugged in; Power outage.Check power outlet; Ensure power cord is securely plugged in; Wait for power to restore.
Unit is running but not collecting water.Humidity level is already low; Air filter is clogged; Room temperature is too low (below 41°F/5°C); Unit is in defrost mode.Check current humidity reading; Clean the air filter; Ensure room temperature is within operating range; Wait for defrost cycle to complete.
Water is leaking from the unit.Drain hose is kinked or blocked; Drain hose connection is loose.Straighten the drain hose and clear any obstructions; Securely reattach the drain hose to the unit.
Unit is making unusual noise.Unit is not on a level surface; Fan obstruction; Internal component issue.Place unit on a level surface; Check for and remove any obstructions from fan; If noise persists, contact customer support.
Dehumidification efficiency is low.Air filter is dirty; Room size exceeds capacity; Doors/windows are open; Air circulation is poor.Clean the air filter; Ensure unit is suitable for room size; Close doors and windows; Improve air circulation.

If the problem persists after trying these solutions, please contact COLZER customer support for assistance.

Warranty and Customer Support

COLZER is committed to providing high-quality products and excellent customer service. Your COLZER CD190S Commercial Dehumidifier comes with a manufacturer's warranty. Please refer to the warranty card included with your product for specific terms and conditions, including coverage period and limitations.

For technical assistance, troubleshooting beyond this guide, or warranty claims, please contact COLZER customer support:

Please have your model number (CD190S) and purchase date ready when contacting support.