1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the Visionis VIS-3002 FPC-5674 Access Control Keypad System. This standalone indoor access control system features a digital touch keypad, a mini controller, Wiegand 26 compatibility, and supports EM cards and key fobs for up to 1000 users. Please read this manual thoroughly before installation and use to ensure proper functionality and safety.
2. Package Contents
Verify that all items listed below are included in your package:
- (1) VIS-3002 Access Control Indoor Only Digital Touch Keypad + Reader Standalone
- (1) VIS-MINI-CNTRL: 1 Door Controller for Access Control Systems
- (10) VS-VIS-KEYTAG: Access Control Proximity Contactless Smart Entry Keyfobs (26 bit, 125khz)
- (1) VISCP200: 12V 2Amp Power Supply Transformer (UL Listed)
- Mounting Screws and Wall Anchors
- Screwdriver
- Wiring Harness
- Diode IN4004 (for relay circuit protection)
- Master Add Card
- Master Delete Card

Figure 2.1: Visionis VIS-3002 Kit Contents, including the mini controller, remote control, Master Add Card, Master Delete Card, Diode IN4004, self-tapping screws, wall anchors, and screwdriver.

Figure 2.2: Visionis VIS-3002 Keypad System components including keypad, mini controller, power supply, and key fobs.
3. Features
- User Capacity: Supports up to 1000 users.
- Access Modes: PIN code, proximity card, and/or proximity key tag.
- Mini Controller (VIS-MINI-CNTRL): Provides enhanced security by storing credentials internally, preventing tampering with the external keypad.
- Wiegand 26 Input/Output: Compatible with various Wiegand readers.
- Anti-Tamper Alarm: Activates if the keypad is illegally removed.
- Backlight Keypad: Easy to operate in low-light conditions.
- Card Support: 125KHz for EM cards and 13.56MHz for MFR cards.
- External Wired Doorbell Support: Allows connection of an external doorbell.
- Fast Reading: Searching time less than 0.1s after reading a card.
- Microprocessor: Built-in USA Atmel microprocessor for high security and reliability.
Video 3.1: Official product overview video for the Visionis VIS-3002 Access Control Keypad System, demonstrating its features and components.

Figure 3.2: Illustration of access methods for the Visionis VIS-3002 keypad: card, PIN code, and NFC phone access.
4. Specifications
| Specification | Detail |
|---|---|
| Model | VIS-3002 FPC-5674 |
| Brand | Visionis |
| Power Source | Corded Electric (12V 2Amp) |
| Connectivity Technology | Wired |
| Control Method | Touch |
| User Capacity | 1000 Users |
| Wiegand Interface | Wiegand 26 |
| Card Frequency | 125KHz (EM cards), 13.56MHz (MFR cards) |
| Operating Temperature | -45°C ~ 55°C (-49°F ~ 131°F) |
| Operating Humidity | 0% ~ 95% |
| Keypad Dimensions (H x W x D) | 116mm (4.56in) x 71mm (2.79in) x 22mm (0.86in) |
| Mini Controller Dimensions (L x W x H) | 65mm (2.56in) x 54mm (2.13in) x 19mm (0.75in) |

Figure 4.1: Dimensions of the Visionis VIS-3002 keypad: 116mm (4.56in) height, 71mm (2.79in) width, 22mm (0.86in) depth.

Figure 4.2: Dimensions of the Visionis VIS-MINI-CNTRL mini controller: 65mm (2.56in) length, 54mm (2.13in) width, 19mm (0.75in) height.
5. Setup and Installation
5.1 Security Considerations
For optimal security, the VIS-MINI-CNTRL mini controller should be installed inside a restricted, secure area. All user credentials are stored on the mini controller, not on the external keypad. This prevents unauthorized access even if the external keypad is tampered with or removed.

Figure 5.1: Illustration of secure installation, with the mini controller installed inside a restricted area, controlling the locking device.
5.2 Wiring the System
The VIS-3002 keypad connects to the VIS-MINI-CNTRL mini controller via a Wiegand 26 interface. The mini controller then manages the locking device (e.g., magnetic lock, electric strike) and other peripherals like an exit button or doorbell.
- Connect the keypad's Wiegand output (D0, D1) to the mini controller's Wiegand input.
- Connect the 12V DC power supply to the mini controller.
- Wire the locking device to the NO (Normally Open) or NC (Normally Closed) terminals on the mini controller, as required by your lock type. Ensure the Diode IN4004 is installed across the lock terminals for relay protection.
- Connect an exit button to the 'OPEN' terminal and GND on the mini controller.
- Connect an external doorbell to the appropriate terminals if desired.

Figure 5.2: Diagram showing the Visionis VIS-MINI-CNTRL mini controller connected to various Wiegand readers, illustrating its versatility.

Figure 5.3: Internal board view and side view of the Visionis VIS-MINI-CNTRL mini controller, showing connection points.

Figure 5.4: The 12V 2Amp power supply transformer included with the Visionis VIS-3002 system.
6. Operation
6.1 Adding Users
Use the Master Add Card to enroll new proximity cards or key fobs. Follow the specific programming instructions provided with your mini controller for adding user PINs.
6.2 Gaining Access
Users can gain access using one of the following methods:
- PIN Code: Enter your assigned PIN code on the keypad.
- Proximity Card/Key Fob: Present your registered card or key fob to the keypad reader.
- Card + PIN: For enhanced security, some configurations may require both a card/key fob and a PIN code.
The keypad features a backlight for easy visibility and operation at night.
6.3 Exiting
To exit, press the connected exit button or use the remote control if configured.
7. Maintenance
- Cleaning: Wipe the keypad surface with a soft, dry cloth. Avoid abrasive cleaners or solvents.
- Connection Check: Periodically inspect all wiring connections to ensure they are secure and free from corrosion.
- Firmware Updates: Check the Visionis website for any available firmware updates for your system.
8. Troubleshooting
- No Power: Ensure the 12V 2Amp power supply is correctly connected and receiving power. Check all wiring.
- Keypad Unresponsive: Verify power supply. If the keypad is completely unresponsive, check for loose connections or damage.
- Access Denied: Ensure the card/key fob is correctly enrolled. Verify the PIN code is correct. Check if the user capacity has been reached.
- Anti-Tamper Alarm: If the alarm sounds, it indicates the keypad has been illegally removed or tampered with. Re-secure the keypad and reset the system if necessary.
- Door Not Unlocking: Check the wiring to the locking device and ensure it is receiving power from the mini controller. Verify the lock type (NO/NC) matches the controller's configuration.
For further assistance, please contact Visionis customer support.
9. Warranty and Support
Visionis products are designed for reliability and performance. For warranty information and technical support, please refer to the official Visionis website or contact their customer service department. Keep your purchase receipt as proof of purchase for warranty claims.