1. Introduction
The Garosa DC4-40V QF-C04 Counter Module is a compact and reliable 4-digit digital display counter designed for various industrial and scientific applications. It features a counting range from 0 to 9999 and includes a memory function to retain data even after power loss. This module operates within a wide voltage range of DC 4-40V, making it versatile for different power supply setups.

Figure 1: Front view of the Garosa QF-C04 Counter Module. This image displays the module's green circuit board with a prominent 4-digit seven-segment display. Text on the board indicates "QF-C01 COUTER" and "Input: DC4V-40V".
2. Safety Information
Please read and understand all safety instructions before installing or operating the module. Failure to follow these instructions may result in electric shock, fire, or damage to the product.
- Ensure the power supply voltage is within the specified DC 4-40V range.
- Disconnect power before making any wiring connections or disconnections.
- Avoid touching exposed circuit components when the module is powered.
- Install the module in a dry environment, away from moisture and extreme temperatures.
- Do not attempt to modify or repair the module yourself. Refer to qualified personnel for service.
3. Product Features
The QF-C04 Counter Module offers the following key features:
- 4-Digit Digital Display: Clear and easy-to-read display with a counting range of 0-9999.
- Memory Function: Retains the last counted value even after power is turned off, ensuring data integrity.
- Wide Voltage Operation: Compatible with DC 4-40V power sources.
- Accumulated +1 Function: Increments the count by one with each input signal.
- Clear Function: Resets the counter to zero.
- Durable Construction: Manufactured with high-quality electronic components for long-term reliability.
4. Specifications
| Parameter | Value |
|---|---|
| Working Voltage | DC 4-40V |
| Display Type | 4-digit Digital Display |
| Counting Range | 0-9999 |
| Memory Function | Yes (Power-off data memory) |
| Inputs | +1 (Increment), Clear (Reset) |
| Dimensions (Approx.) | 65mm x 29mm x 20mm (Length x Width x Height) |

Figure 2: Dimensions of the QF-C04 Counter Module. This image shows the module with measurements indicating its length (65mm), width (29mm), and height (20mm).
5. Setup and Wiring
Follow these steps to properly set up and wire your QF-C04 Counter Module:
- Power Connection:
Connect your DC 4-40V power supply to the V+ and GND terminals on the module. Ensure correct polarity (V+ for positive, GND for negative).
- Increment Input (+1):
The "+1" terminal is used to increment the counter. Connect a momentary switch or a sensor module output to this terminal. Each time the "+1" input receives a signal (e.g., a pulse from a button press or sensor trigger), the counter will increase by one.
- Clear Input (CLR):
The "CLR" terminal is used to reset the counter to zero. Connect a momentary switch to this terminal. When the "CLR" input is activated, the display will reset to 0000.

Figure 3: Wiring diagram for the QF-C04 Counter Module. This image highlights the input terminals for power (V+, GND), increment (+1), and clear (CLR), along with voltage and input type descriptions.
Note: Always double-check your wiring connections before applying power to prevent damage to the module or connected devices.
6. Operating Instructions
Operating the QF-C04 Counter Module is straightforward:
- Power On: Once correctly wired, apply DC 4-40V power. The module will display the last saved count (due to its memory function) or 0000 if it's the first use or after a manual clear.
- Incrementing the Count: Activate the "+1" input (e.g., press the connected button or trigger the sensor). The displayed count will increase by one. The counter can count up to 9999.
- Clearing the Count: Activate the "CLR" input (e.g., press the connected button). The displayed count will reset to 0000.
- Memory Function: The module automatically saves the current count. If power is removed and then reapplied, the module will resume counting from the last saved value.
7. Maintenance
The Garosa QF-C04 Counter Module requires minimal maintenance to ensure long-term performance:
- Cleaning: Use a soft, dry cloth to gently wipe the module. Do not use abrasive cleaners or solvents.
- Environment: Keep the module in a clean, dry, and dust-free environment. Avoid exposure to direct sunlight, high humidity, or corrosive substances.
- Inspection: Periodically inspect wiring connections to ensure they are secure and free from damage.
8. Troubleshooting
If you encounter issues with your QF-C04 Counter Module, refer to the following troubleshooting guide:
| Problem | Possible Cause | Solution |
|---|---|---|
| Display is blank | No power or incorrect power connection. | Check power supply (DC 4-40V) and ensure V+ and GND are correctly wired. |
| Counter does not increment | Faulty "+1" input connection or switch/sensor. | Verify the connection to the "+1" terminal. Test the switch or sensor independently. |
| Counter does not clear | Faulty "CLR" input connection or switch. | Verify the connection to the "CLR" terminal. Test the clear switch independently. |
| Incorrect count | Interference or rapid/bouncing input signals. | Ensure input signals are clean. Consider adding debouncing circuitry if using mechanical switches. |
9. Warranty Information
Garosa products are manufactured to high-quality standards. This product comes with a standard manufacturer's warranty against defects in materials and workmanship. Please refer to your purchase documentation or contact your retailer for specific warranty terms and conditions.
The warranty does not cover damage caused by improper installation, misuse, unauthorized modification, or external factors such as power surges or environmental conditions.
10. Customer Support
For technical assistance, troubleshooting not covered in this manual, or warranty inquiries, please contact Garosa customer support through the retailer where you purchased the product or visit the official Garosa website for contact information.
When contacting support, please have your product model (QF-C04) and purchase details readily available.