Beurer PO 45 (Model 45434)

Download PDF
Contents

Beurer PO 45 Pulse Oximeter User Manual

Model: PO 45 (Model 45434)

Brand: Beurer

Introduction

The Beurer PO 45 Pulse Oximeter is a compact and reliable device designed for convenient self-monitoring of arterial oxygen saturation (SpO2), heart rate (pulse), and perfusion index (PI). It provides accurate and painless measurements, making it suitable for home use, travel, and high-altitude sports. This manual provides essential information for the safe and effective operation of your device.

Beurer PO 45 Pulse Oximeter

Image: The Beurer PO 45 Pulse Oximeter, a compact device for measuring blood oxygen saturation and pulse rate.

Key Features

  • Determination of arterial oxygen saturation (SpO2), heart rate (pulse), and perfusion index (PI).
  • Easy and painless measurement.
  • Indication of unstable measurements for reliable readings.
  • Small and lightweight, ideal for home and travel.
  • Easy-to-read color display with seven viewing perspectives.
  • Adjustable display brightness.
  • Graphical pulse display.
  • Includes wrist strap and belt pouch.

What's in the Box

  • 1 x Beurer PO 45 Pulse Oximeter
  • 2 x AAA Batteries
  • 1 x Wrist Strap
  • 1 x Belt Pouch

Setup

Inserting Batteries

  1. Open the battery compartment cover on the back of the device.
  2. Insert the two AAA batteries, ensuring correct polarity (+/-).
  3. Close the battery compartment cover securely.

Initial Power On

Press the power button to turn on the device. The display will light up.

Operating Instructions

Taking a Measurement

  1. Ensure your finger is clean and free of nail polish, artificial nails, or other cosmetics.
  2. Open the clamp of the pulse oximeter.
  3. Insert one finger (preferably the index finger) into the opening until it touches the stop.
  4. Release the clamp. Ensure the device is securely placed on your finger.
  5. Press the power button to start the measurement.
  6. Keep your hand still during the measurement. Movement can affect accuracy.
  7. The SpO2, pulse rate, and perfusion index (PI) values will appear on the display within a few seconds.
Finger placement for measurement

Image: Proper finger placement for an easy and painless measurement with the pulse oximeter.

Display showing SpO2, Pulse, and PI

Image: The device display showing the determined arterial oxygen saturation (SpO2), heart rate (pulse), and perfusion index (PI).

Understanding the Display

The color display shows your SpO2 percentage, pulse rate in beats per minute (bpm), and a graphical representation of your pulse. The display brightness can be adjusted, and there are seven viewing perspectives available for optimal readability.

Graphical pulse display

Image: A close-up of the pulse oximeter display, highlighting the graphical pulse visualization.

Interpreting Readings

Oxygen Saturation (SpO2): This indicates the percentage of hemoglobin in arterial blood that is loaded with oxygen. Normal SpO2 values for healthy individuals typically range from 94% to 99%. Lower values may indicate respiratory issues.

Heart Rate (Pulse): This is the number of heartbeats per minute.

Perfusion Index (PI): This provides information about the blood flow in your finger. A very low PI value might affect measurement accuracy.

If the measurement is unstable, a question mark symbol will appear on the screen. In such cases, reposition your finger and repeat the measurement to ensure reliable readings.

Unstable measurement symbol

Image: The display showing a symbol indicating an unstable measurement, prompting the user to re-measure.

Usage for High-Altitude Sports

The Beurer PO 45 is suitable for monitoring oxygen saturation during high-altitude activities such as mountaineering, skiing, or sports aviation, where oxygen levels can be lower.

Pulse oximeter used in high-altitude sports

Image: The Beurer PO 45 Pulse Oximeter shown in the context of high-altitude sports, such as hiking and skiing.

Maintenance

Cleaning

Clean the device with a soft, dry cloth. Do not use abrasive cleaners or immerse the device in water.

Storage

Store the pulse oximeter in a cool, dry place, away from direct sunlight and extreme temperatures. If not in use for an extended period, remove the batteries.

Battery Replacement

When the battery indicator appears on the display, replace both AAA batteries with new ones. Follow the battery insertion steps outlined in the Setup section.

Troubleshooting

ProblemPossible CauseSolution
No display/Device does not turn onBatteries are dead or incorrectly inserted.Check battery polarity or replace batteries.
Unstable or inaccurate readingsFinger not properly inserted, movement during measurement, nail polish/cosmetics, cold fingers.Ensure proper finger placement, remain still, remove nail polish/cosmetics, warm hands if cold.
"?" symbol on displayMeasurement is unstable.Reposition finger and repeat measurement.

Specifications

ParameterValue
Model Number45434
Dimensions (L x W x H)12 x 8.3 x 5.8 cm
Weight (without batteries)30 g
Power Supply2 x 1.5V AAA batteries
SpO2 Measurement Range70 - 100%
Pulse Measurement Range30 - 250 beats/minute
PI Measurement Range0.3 - 20%
SpO2 Accuracy± 2% (70-100%)
Pulse Accuracy± 2 beats/minute (30-250 bpm)
Automatic Shut-offYes

Warranty and Support

For warranty information and customer support, please refer to the official Beurer website or contact Beurer customer service directly. Keep your purchase receipt as proof of purchase.

Manufacturer: Beurer

© 2025 Beurer. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.