This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of the Danfoss Cartridge Pressure Switch, model 2UA305W I/20 061F8333. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and to prevent potential hazards.
Safety Information
WARNING:
- Always disconnect power before installing or servicing the pressure switch.
- Installation and maintenance should only be performed by qualified personnel.
- Ensure the pressure switch is compatible with the system's operating pressure and fluid type.
- Do not exceed the maximum rated pressure or electrical load.
- Refer to local codes and regulations for proper installation procedures.
Product Overview
The Danfoss Cartridge Pressure Switch is designed for reliable pressure monitoring and control in various industrial and scientific applications. It features a 1/4 inch flare female connection and is built for durability and precision.

Figure 1: Danfoss Cartridge Pressure Switch (Model 2UA305W I/20 061F8333). This image shows the compact design of the pressure switch, featuring a brass 1/4 inch flare female connector on one end and black electrical wires extending from the other, secured with a red band.
Key Components:
- Pressure Port: 1/4 inch Flare Female connection for system integration.
- Electrical Connections: Wires for connecting to control circuits.
- Switch Mechanism: Internal components responsible for pressure sensing and switching action.
Setup and Installation
- Preparation:
- Ensure the system is depressurized and power is disconnected.
- Verify that the pressure switch specifications match the system requirements.
- Mounting:
- Mount the pressure switch in a location free from excessive vibration and extreme temperatures.
- The mounting type is Surface Mount. Secure the switch firmly using appropriate fasteners (not included).
- Pressure Connection:
- Connect the 1/4 inch flare female port of the switch to the system's pressure line.
- Use appropriate sealing methods (e.g., thread sealant or PTFE tape) to ensure a leak-free connection. Do not overtighten.
- Electrical Connection:
- Connect the electrical wires to the control circuit according to the system's wiring diagram.
- The connector type is Molex. Ensure all connections are secure and insulated.
- Confirm correct polarity and voltage.
- System Check:
- Once all connections are made, slowly repressurize the system and check for leaks.
- Restore power and verify the switch's operation.
Operating Instructions
The Danfoss Cartridge Pressure Switch operates automatically based on the system's pressure. It is designed to open or close an electrical circuit when a predefined pressure threshold is reached.
- Automatic Operation: The switch will activate or deactivate connected equipment (e.g., pumps, compressors) when the system pressure crosses its set point.
- Monitoring: Regularly monitor the system pressure to ensure it remains within safe operating limits and that the switch is functioning as expected.
- Control Method: The control method is Touch, implying it is designed to respond to pressure changes rather than manual input for its primary function.
Maintenance
The Danfoss Cartridge Pressure Switch is designed for minimal maintenance. However, periodic checks are recommended to ensure continued reliable operation.
- Visual Inspection: Periodically inspect the switch for any signs of physical damage, corrosion, or loose connections.
- Leak Checks: Regularly check the pressure connection for any leaks.
- Functional Test: If possible and safe, periodically test the switch's operation by simulating pressure changes to confirm it activates at the correct set points.
- Cleaning: Keep the exterior of the switch clean and free from dust and debris. Do not use harsh chemicals.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Switch does not activate/deactivate. | Incorrect wiring, no power, pressure outside operating range, faulty switch. | Check wiring connections. Verify power supply. Confirm system pressure is within the switch's range. Test switch functionality; replace if faulty. |
| Pressure leaks at connection. | Improper sealing, loose connection, damaged threads. | Depressurize system. Reapply thread sealant or PTFE tape. Tighten connection appropriately. Inspect threads for damage. |
| Erratic switch behavior. | Vibration, pressure fluctuations, electrical interference. | Ensure stable mounting. Investigate system for pressure instability. Check for proper electrical shielding. |
Specifications
| Feature | Detail |
|---|---|
| Model Number | 2UA305W I/20 061F8333 |
| Brand | Danfoss |
| Switch Type | Pressure Switch |
| Connector Type | Molex |
| Mounting Type | Surface Mount |
| Actuator Type | Push Button (Note: This refers to the internal sensing mechanism, not external user interaction.) |
| Control Method | Touch (Note: This refers to the pressure sensing mechanism.) |
| Unit Count | 1.0 Count |
| Connectivity Protocol | X-10 (Note: This may refer to a specific communication standard if integrated into a smart system.) |
| Weight | 0.73 LBR (approx. 0.33 kg) |
| UPC-EAN | 5702428262569 |
Warranty and Support
For warranty information and technical support, please refer to the official Danfoss website or contact your authorized Danfoss distributor. Keep your purchase receipt for warranty claims.
Danfoss Official Website: www.danfoss.com