ResMed AirFit P10 Frame System

ResMed AirFit P10 Frame System User Manual

For the ResMed AirFit P10 Nasal Pillows CPAP Mask

Introduction

This manual provides essential information for the proper use, care, and maintenance of your ResMed AirFit P10 Frame System. The AirFit P10 Frame System is designed to be lightweight and easy to use, providing quiet comfort and stability for CPAP therapy. This set includes the frame system with a short tube and nasal pillows cushion. Headgear is not included with this frame system.

A prescription is required for the complete CPAP system.

Product Overview

The ResMed AirFit P10 Frame System consists of the mask frame, short tube, and nasal pillows cushion. These components work together to deliver air pressure for your CPAP therapy.

ResMed AirFit P10 Frame System components including nasal pillows, short tube, and frame, without headgear.

Image: The ResMed AirFit P10 Frame System, showing the nasal pillows cushion, short tube, and the frame without headgear. It highlights its small, lightweight, and easy-to-use design.

The nasal pillows cushion is designed to sit comfortably at the entrance of your nostrils, providing a seal without covering your entire nose or mouth. The short tube connects the nasal pillows to your main CPAP tubing.

Setup

To set up your AirFit P10 Frame System:

  1. Identify Components: Ensure you have the nasal pillows cushion, the mask frame, and the short tube.
  2. Attach Nasal Pillows: Gently push the nasal pillows cushion onto the frame until it clicks securely into place. Ensure the 'L' and 'R' indicators on the pillows align with the corresponding sides of the frame.
  3. Connect Short Tube: Attach the short tube to the swivel connector on the mask frame.
  4. Check Size: Verify that the nasal pillows cushion size is appropriate for your nostrils. The correct size should provide a comfortable seal without feeling too tight or too loose.
A hand holding the ResMed AirFit P10 nasal pillows cushion, with an arrow pointing to the 'L' size indicator.

Image: A close-up of a hand holding the nasal pillows cushion, indicating where to check the size marking (L for Large) on the frame system.

Once assembled, connect the short tube to your CPAP machine's main air tubing. If you are using a headgear (sold separately), attach it to the frame system according to its specific instructions.

Operating

To use your ResMed AirFit P10 Frame System:

  1. Position the Mask: Place the nasal pillows into your nostrils. If using headgear, adjust it to ensure a secure but comfortable fit. The mask should feel stable without excessive pressure.
  2. Start CPAP Therapy: Turn on your CPAP machine. You should feel a gentle flow of air through the nasal pillows.
  3. Check for Leaks: While lying down, check for any air leaks around the nasal pillows. Minor leaks are normal, but significant leaks can reduce therapy effectiveness. Adjust the mask position or headgear if necessary.
  4. Comfort: Ensure the mask is comfortable and does not cause any skin irritation or pressure points.

Maintenance

Regular cleaning and replacement of your AirFit P10 Frame System components are crucial for hygiene and effective therapy. We recommend replacing your frame system every three months or sooner if signs of wear appear.

Daily Care:

  • Replace at signs of deterioration.
  • If required, wipe the outside of the foam with CPAP wipes or similar alcohol-free wipes.
  • Lay flat on a towel to air dry.

Important Cleaning Restrictions:

  • Do not expose to direct sunlight.
  • Do not put in a dishwasher or washing machine.
  • Do not use alcohol or bleach to clean.
A checklist of daily care instructions for the AirFit frame system, with green checkmarks for recommended actions and red X marks for actions to avoid.

Image: A visual guide for daily care of the AirFit frame system, detailing what to do (replace, wipe, air dry) and what not to do (direct sunlight, dishwasher, alcohol/bleach).

Troubleshooting

If you experience issues with your AirFit P10 Frame System, consider the following:

Signs it might be time to replace your frame system:

  • You are experiencing excessive leaks.
  • Your therapy feels less effective than usual.
  • Your frame system starts to show wear and tear.
A graphic showing the AirFit P10 frame system with a text overlay recommending replacement every three months and listing signs of wear.

Image: A visual reminder to replace the frame system every three months, accompanied by a list of indicators such as excessive leaks, reduced therapy effectiveness, or visible wear and tear.

If issues persist after checking these points, consult your healthcare provider or CPAP equipment supplier.

Specifications

FeatureDetail
Product Dimensions7 x 4.5 x 1.6 inches
Product Weight3.53 ounces
ManufacturerResMed
ASINB08MKYZQYL

Warranty and Support

For warranty information and customer support, please refer to the documentation provided with your original CPAP system or visit the official ResMed website. ResMed is dedicated to helping individuals with sleep apnea, COPD, and related issues improve their lives.

ResMed company logo, featuring a stylized wave pattern in blue and red dots above the 'ResMed' text.

Image: The ResMed company logo.

Related Documents - AirFit P10 Frame System

Preview ResMed AirFit P10 Nasal Pillows System User Guide
User guide for the ResMed AirFit P10 Nasal Pillows System, providing instructions on fitting, use, cleaning, and troubleshooting for CPAP therapy.
Preview ResMed AirFit P10 Nasal Pillows System Assembly and Disassembly Guide
A guide detailing the disassembly and reassembly steps for the ResMed AirFit P10 Nasal Pillows System, including instructions for attaching pillows and headgear.
Preview ResMed AirFit N30i & P30i Frame Fitting Instructions Guide
Learn how to correctly fit your ResMed AirFit N30i nasal mask or AirFit P30i nasal pillow mask frame using this simple measurement guide. Find the right size for optimal comfort and therapy.
Preview ResMed AirFit P10 & AirFit P10 for Her CPAP Nasal Pillow Mask Guide
Comprehensive guide to the ResMed AirFit P10 and AirFit P10 for Her nasal pillow CPAP masks. Features, components, fitting instructions, and ordering information for optimal sleep apnea therapy.
Preview ResMed AirFit P10 Nasal Pillows System Fitting Guide and Product Information
A comprehensive guide to fitting, using, and understanding the ResMed AirFit P10 nasal pillows mask, highlighting its quiet operation, comfort, and ease of use for CPAP therapy.
Preview ResMed AirFit N30i/P30i CPAP Mask Frame Fitting Guide
ResMed AirFit N30i and P30i CPAP mask frame fitting instructions. Learn how to measure your face to select the correct mask frame size using a simple guide.