1. Introduction
The Parkside PTIA 1 Infrared Thermometer is a non-contact device designed for quick and accurate surface temperature measurement. It is an ideal tool for identifying thermal bridges and areas at risk of mold formation in various environments. This manual provides essential information for the safe and effective operation of your device.
Key features include an 8-point laser for precise measurement area indication, a color display with a signal for temperature differences, and a wide measurement range from -50 °C to +380 °C. The device also offers simple and reference measurement modes, a battery change indicator, and an automatic shutdown function to conserve power.
Image 1.1: The Parkside PTIA 1 Infrared Thermometer, a non-contact temperature measurement device.
2. Safety Instructions
Please read and understand all safety instructions before using the device. Failure to follow these instructions may result in injury or damage to the device.
- Laser Safety: This device uses a Class 2 laser. Do not stare directly into the laser beam or point it at people or animals. Avoid direct eye exposure.
- Operating Environment: Do not use the device in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust.
- Temperature Limits: Do not expose the device to extreme temperatures outside its operating range or to high humidity.
- Battery Handling: Ensure correct battery polarity. Do not mix old and new batteries or different types of batteries. Remove batteries if the device will not be used for an extended period. Dispose of batteries responsibly.
- Maintenance: Do not attempt to modify or repair the device yourself. Refer all servicing to qualified personnel.
- Children: Keep the device out of reach of children.
3. Product Overview and Components
Familiarize yourself with the main parts of your infrared thermometer:
- Infrared Sensor: Detects surface temperature.
- Laser Pointer: Indicates the center of the measurement area.
- Display: Shows temperature readings, measurement units, and mode indicators.
- Measurement Trigger: Activates the measurement.
- Mode Buttons: For selecting measurement modes (e.g., simple, reference).
- Unit Selection Button: To switch between Celsius (°C) and Fahrenheit (°F).
- Battery Compartment: Located in the handle.
Included Components:
- Parkside PTIA 1 Infrared Thermometer
- 2 x AA Batteries
- 1 x 9V Battery
- User Manual
Image 3.1: Front view of the thermometer, showing the display and buttons.
4. Setup
4.1 Battery Installation
- Locate the battery compartment cover on the handle of the device.
- Open the cover by sliding or unlatching it.
- Insert the 2 AA batteries and 1 9V battery, ensuring correct polarity (+ and -) as indicated inside the compartment.
- Close the battery compartment cover securely.
4.2 Initial Power-On and Unit Selection
- Press the measurement trigger to turn on the device. The display will illuminate.
- To switch between Celsius (°C) and Fahrenheit (°F), press the dedicated unit selection button (usually labeled °C/°F or similar) located near the display.
- The device is now ready for use.
5. Operating Instructions
5.1 Taking a Measurement
- Point the infrared sensor towards the surface you wish to measure.
- Press and hold the measurement trigger. The 8-point laser will activate, indicating the approximate measurement area.
- The temperature reading will appear on the display. Release the trigger to hold the reading.
- The device has an optics ratio of 12:1, meaning that at a distance of 12 units, the measurement spot diameter is 1 unit. For example, at 12 meters, the spot diameter is 1 meter. Ensure you are at an appropriate distance for accurate readings.
Image 5.1: Measuring a window frame, showing the 8-point laser indicating the measurement area.
5.2 Measurement Modes
The PTIA 1 offers different operating modes:
- Simple Measurement: This is the default mode for quick, direct temperature readings of a surface.
- Reference Measurement: In this mode, you can set a reference temperature. The device will then display color indications and signals to highlight differences between the measured value and the set reference value, which is useful for identifying anomalies like thermal bridges. Consult the on-screen prompts or specific mode button for activation.
Image 5.2: The thermometer in use, measuring the temperature of a fireplace.
Image 5.3: The thermometer measuring the surface temperature of a stovetop.
5.3 Automatic Shutdown
To conserve battery life, the device will automatically shut down after approximately 60 seconds of inactivity.
6. Maintenance
6.1 Cleaning the Device
- Wipe the device with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Ensure the infrared lens is clean and free of dust or debris for accurate measurements. Use a soft, lint-free cloth specifically designed for optics.
- Do not immerse the device in water or any other liquid.
6.2 Battery Replacement
When the battery change indicator appears on the display, replace the batteries as described in the 'Battery Installation' section (4.1). Always replace all batteries at the same time with new ones of the same type.
6.3 Storage
Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for an extended period, remove the batteries to prevent leakage.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not turn on. | Batteries are dead or incorrectly installed. | Check battery polarity and replace batteries if necessary. |
| Inaccurate readings. | Infrared lens is dirty; distance to spot ratio is incorrect; emissivity setting (if applicable, not explicitly mentioned for this model) is wrong; object is too small. | Clean the lens. Ensure correct measurement distance. Measure larger objects. |
| Laser not visible. | Laser function is off or obstructed. | Ensure the laser is enabled (if there's a toggle). Check for obstructions. |
| Display shows 'Lo' or 'Hi'. | Temperature is outside the measurement range. | The device cannot measure temperatures below -50°C or above +380°C. |
8. Specifications
| Feature | Specification |
|---|---|
| Model | PTIA 1 |
| Measurement Range | -50 °C to +380 °C (-58 °F to +716 °F) |
| Measurement Units | °C / °F (selectable) |
| Optics (Distance to Spot Ratio) | 12:1 |
| Laser | 8-point laser for measurement area indication |
| Display Type | Color display |
| Special Features | Contactless, High accuracy, Quick read system |
| Operating Modes | Simple measurement / Reference measurement |
| Automatic Shutdown | Approx. 60 seconds of inactivity |
| Power Source | Battery operated |
| Batteries | 2 x AA batteries (included), 1 x 9V battery (included) |
| Manufacturer | Lidl |
| Package Dimensions | 21.3 x 13.3 x 5.3 cm |
| Package Weight | 333 g |
9. Warranty and Support
Warranty Information: Specific warranty terms and conditions may vary by region and retailer. Please refer to the warranty documentation provided with your purchase or contact your point of sale for detailed information regarding the warranty period and coverage.
Customer Support: For technical assistance, troubleshooting beyond this manual, or inquiries about your Parkside PTIA 1 Infrared Thermometer, please contact the retailer where the product was purchased or the manufacturer's customer service department. Contact details can typically be found on the product packaging or the manufacturer's official website.