Parkside PTIA 1

Parkside PTIA 1 Infrared Thermometer User Manual

Model: PTIA 1 | Brand: Parkside

1. Introduction

The Parkside PTIA 1 Infrared Thermometer is a non-contact device designed for quick and accurate surface temperature measurement. It is an ideal tool for identifying thermal bridges and areas at risk of mold formation in various environments. This manual provides essential information for the safe and effective operation of your device.

Key features include an 8-point laser for precise measurement area indication, a color display with a signal for temperature differences, and a wide measurement range from -50 °C to +380 °C. The device also offers simple and reference measurement modes, a battery change indicator, and an automatic shutdown function to conserve power.

Parkside PTIA 1 Infrared Thermometer

Image 1.1: The Parkside PTIA 1 Infrared Thermometer, a non-contact temperature measurement device.

2. Safety Instructions

Please read and understand all safety instructions before using the device. Failure to follow these instructions may result in injury or damage to the device.

  • Laser Safety: This device uses a Class 2 laser. Do not stare directly into the laser beam or point it at people or animals. Avoid direct eye exposure.
  • Operating Environment: Do not use the device in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust.
  • Temperature Limits: Do not expose the device to extreme temperatures outside its operating range or to high humidity.
  • Battery Handling: Ensure correct battery polarity. Do not mix old and new batteries or different types of batteries. Remove batteries if the device will not be used for an extended period. Dispose of batteries responsibly.
  • Maintenance: Do not attempt to modify or repair the device yourself. Refer all servicing to qualified personnel.
  • Children: Keep the device out of reach of children.

3. Product Overview and Components

Familiarize yourself with the main parts of your infrared thermometer:

  • Infrared Sensor: Detects surface temperature.
  • Laser Pointer: Indicates the center of the measurement area.
  • Display: Shows temperature readings, measurement units, and mode indicators.
  • Measurement Trigger: Activates the measurement.
  • Mode Buttons: For selecting measurement modes (e.g., simple, reference).
  • Unit Selection Button: To switch between Celsius (°C) and Fahrenheit (°F).
  • Battery Compartment: Located in the handle.

Included Components:

  • Parkside PTIA 1 Infrared Thermometer
  • 2 x AA Batteries
  • 1 x 9V Battery
  • User Manual
Front view of Parkside PTIA 1 Infrared Thermometer

Image 3.1: Front view of the thermometer, showing the display and buttons.

4. Setup

4.1 Battery Installation

  1. Locate the battery compartment cover on the handle of the device.
  2. Open the cover by sliding or unlatching it.
  3. Insert the 2 AA batteries and 1 9V battery, ensuring correct polarity (+ and -) as indicated inside the compartment.
  4. Close the battery compartment cover securely.

4.2 Initial Power-On and Unit Selection

  1. Press the measurement trigger to turn on the device. The display will illuminate.
  2. To switch between Celsius (°C) and Fahrenheit (°F), press the dedicated unit selection button (usually labeled °C/°F or similar) located near the display.
  3. The device is now ready for use.

5. Operating Instructions

5.1 Taking a Measurement

  1. Point the infrared sensor towards the surface you wish to measure.
  2. Press and hold the measurement trigger. The 8-point laser will activate, indicating the approximate measurement area.
  3. The temperature reading will appear on the display. Release the trigger to hold the reading.
  4. The device has an optics ratio of 12:1, meaning that at a distance of 12 units, the measurement spot diameter is 1 unit. For example, at 12 meters, the spot diameter is 1 meter. Ensure you are at an appropriate distance for accurate readings.
Thermometer measuring a window frame with laser points visible

Image 5.1: Measuring a window frame, showing the 8-point laser indicating the measurement area.

5.2 Measurement Modes

The PTIA 1 offers different operating modes:

  • Simple Measurement: This is the default mode for quick, direct temperature readings of a surface.
  • Reference Measurement: In this mode, you can set a reference temperature. The device will then display color indications and signals to highlight differences between the measured value and the set reference value, which is useful for identifying anomalies like thermal bridges. Consult the on-screen prompts or specific mode button for activation.
Thermometer measuring a fireplace

Image 5.2: The thermometer in use, measuring the temperature of a fireplace.

Thermometer measuring a stovetop

Image 5.3: The thermometer measuring the surface temperature of a stovetop.

5.3 Automatic Shutdown

To conserve battery life, the device will automatically shut down after approximately 60 seconds of inactivity.

6. Maintenance

6.1 Cleaning the Device

  • Wipe the device with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Ensure the infrared lens is clean and free of dust or debris for accurate measurements. Use a soft, lint-free cloth specifically designed for optics.
  • Do not immerse the device in water or any other liquid.

6.2 Battery Replacement

When the battery change indicator appears on the display, replace the batteries as described in the 'Battery Installation' section (4.1). Always replace all batteries at the same time with new ones of the same type.

6.3 Storage

Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for an extended period, remove the batteries to prevent leakage.

7. Troubleshooting

Problem Possible Cause Solution
Device does not turn on. Batteries are dead or incorrectly installed. Check battery polarity and replace batteries if necessary.
Inaccurate readings. Infrared lens is dirty; distance to spot ratio is incorrect; emissivity setting (if applicable, not explicitly mentioned for this model) is wrong; object is too small. Clean the lens. Ensure correct measurement distance. Measure larger objects.
Laser not visible. Laser function is off or obstructed. Ensure the laser is enabled (if there's a toggle). Check for obstructions.
Display shows 'Lo' or 'Hi'. Temperature is outside the measurement range. The device cannot measure temperatures below -50°C or above +380°C.

8. Specifications

Feature Specification
Model PTIA 1
Measurement Range -50 °C to +380 °C (-58 °F to +716 °F)
Measurement Units °C / °F (selectable)
Optics (Distance to Spot Ratio) 12:1
Laser 8-point laser for measurement area indication
Display Type Color display
Special Features Contactless, High accuracy, Quick read system
Operating Modes Simple measurement / Reference measurement
Automatic Shutdown Approx. 60 seconds of inactivity
Power Source Battery operated
Batteries 2 x AA batteries (included), 1 x 9V battery (included)
Manufacturer Lidl
Package Dimensions 21.3 x 13.3 x 5.3 cm
Package Weight 333 g

9. Warranty and Support

Warranty Information: Specific warranty terms and conditions may vary by region and retailer. Please refer to the warranty documentation provided with your purchase or contact your point of sale for detailed information regarding the warranty period and coverage.

Customer Support: For technical assistance, troubleshooting beyond this manual, or inquiries about your Parkside PTIA 1 Infrared Thermometer, please contact the retailer where the product was purchased or the manufacturer's customer service department. Contact details can typically be found on the product packaging or the manufacturer's official website.

Related Documents - PTIA 1

Preview Parkside PTIA 1 Infrared Thermometer - User Manual and Safety Guide
Comprehensive user manual and safety guide for the Parkside PTIA 1 Infrared Thermometer. Learn about its features, intended use, operation, and safety precautions for accurate non-contact temperature measurements.
Preview PARKSIDE PBHITM A1 Infrared Thermometer User Manual
Comprehensive user manual for the PARKSIDE PBHITM A1 Infrared Thermometer, covering operation, safety instructions, technical specifications, and maintenance.
Preview Parkside PTI 380 C3 Infrared Thermometer: Operation and Safety Manual
User manual and safety instructions for the Parkside PTI 380 C3 Infrared Thermometer. Learn about its features, operation, technical specifications, and safety precautions for accurate temperature measurement.
Preview Manual de Usuario Batería Parkside PAPK 12 B1 4 Ah
Instrucciones detalladas y directrices de seguridad para la batería recargable Parkside PAPK 12 B1 4 Ah, incluyendo información sobre carga, mantenimiento y garantía.
Preview PARKSIDE PSSFS 3 A2 Non-Contact Voltage Detector User Manual
Detailed user manual for the PARKSIDE PSSFS 3 A2 Non-Contact Voltage Detector. Includes operation, safety instructions, technical data, and warranty information.
Preview Parkside PWBKA 4 A1 Thermal Imaging Camera User Manual
Comprehensive user manual for the Parkside PWBKA 4 A1 Thermal Imaging Camera, covering setup, operation, safety guidelines, and technical specifications. Learn how to use your thermal imaging camera effectively for various applications.