boreal MBRS18-W200

boreal BRISA 18,000 BTU 1.5 Tons Dual Zone Wall Mount Ductless Mini Split System User Manual

Model: MBRS18-W200

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your boreal BRISA 18,000 BTU 1.5 Tons Dual Zone Wall Mount Ductless Mini Split System. Please read this manual thoroughly before installing or operating the unit and retain it for future reference. Proper installation and maintenance are crucial for optimal performance and longevity of the system.

2. Safety Information

Important: Installation of this air conditioning system must be performed by a state-licensed HVAC contractor. Improper installation can lead to electric shock, fire, water leakage, or other serious hazards, and will void the product warranty.

3. Product Overview

The boreal BRISA Dual Zone Mini Split System provides efficient heating and cooling for two separate areas. The system consists of an outdoor condenser unit, two indoor wall-mounted air handlers, and a wireless remote control for each indoor unit.

System Components

boreal BRISA Dual Zone Mini Split System with outdoor condenser, two indoor units, and remote control

Figure 3.1: Complete boreal BRISA Dual Zone Mini Split System, showing the outdoor condenser, two indoor wall-mounted units, and a remote control.

boreal BRISA Outdoor Condenser Unit

Figure 3.2: The outdoor condenser unit, responsible for heat exchange with the outside air.

boreal BRISA Indoor Wall Mounted Air Handler Unit

Figure 3.3: An indoor wall-mounted air handler unit, which distributes conditioned air within the room.

boreal BRISA Wireless Remote Control

Figure 3.4: The wireless remote control for operating the indoor air handler unit.

The system utilizes inverter technology for energy efficiency and precise temperature control. It operates on 230V power.

4. Setup and Installation

As stated in the safety information, professional installation by a state-licensed HVAC contractor is mandatory for this system. This ensures compliance with local codes, proper refrigerant handling, electrical connections, and warranty validity.

Components Required (Not Included)

Installation accessories including lineset, surge protector, and condenser pad

Figure 4.1: Example of additional components often required for mini-split installation, such as lineset, surge protector, and a condenser pad.

Your HVAC contractor will ensure all necessary components are correctly sized and installed according to manufacturer specifications and local building codes.

5. Operating Instructions

Each indoor unit is controlled by its dedicated wireless remote control. Ensure the remote has fresh batteries and is pointed towards the indoor unit when transmitting commands.

Remote Control Functions

boreal BRISA Wireless Remote Control with labeled buttons

Figure 5.1: Wireless remote control for the boreal BRISA system. Key buttons include ON/OFF, Mode, Fan, Temp, and various function buttons.

6. Maintenance

Regular maintenance ensures optimal performance, energy efficiency, and extends the lifespan of your mini-split system. Always disconnect power to the unit before performing any maintenance.

Indoor Unit Maintenance

Outdoor Unit Maintenance

For detailed annual inspections and maintenance, it is recommended to schedule service with a licensed HVAC professional.

7. Troubleshooting

Before contacting service, review the following common issues and solutions:

ProblemPossible CauseSolution
Unit does not turn on.No power, remote control batteries dead, circuit breaker tripped.Check power supply, replace remote batteries, reset circuit breaker.
Insufficient cooling/heating.Dirty air filters, blocked outdoor unit, wrong mode selected, temperature setting too high/low.Clean air filters, clear obstructions from outdoor unit, select correct mode, adjust temperature.
Water leakage from indoor unit.Clogged drain line, improper installation.Check and clear drain line. If issue persists, contact HVAC technician.
Unusual noise.Loose parts, fan obstruction, refrigerant issues.Turn off unit and inspect for loose parts or obstructions. If noise continues, contact HVAC technician.

If troubleshooting steps do not resolve the issue, contact a licensed HVAC professional for assistance. Do not attempt to repair the unit yourself, as this can be dangerous and may void the warranty.

8. Specifications

Key technical specifications for the boreal BRISA 18,000 BTU 1.5 Tons Dual Zone Mini Split System (Model: MBRS18-W200).

FeatureValue
Brandboreal
Model NumberMBRS18-W200
Cooling Power18,000 British Thermal Units (BTU)
Tonnage1.5 Tons
Voltage230 Volts
SEER (Seasonal Energy Efficiency Ratio)22
EER (Energy Efficiency Ratio)12.50
HSPF (Heating Seasonal Performance Factor)11
Room Coverage600 - 1,000 sqft
RefrigerantR 410A
Special FeatureRemote Controlled
Form FactorMini-Split

Unit Dimensions

Table of Boreal Brisa Multi Indoor and Outdoor Unit Measurements

Figure 8.1: Dimensions (Width x Height x Depth) for various BTU indoor and outdoor units in the Boreal Brisa Multi series. For this 18,000 BTU system, refer to the 9,000 BTU entries for indoor units and the 18,000 BTU entry for the outdoor unit.

Note: The 18,000 BTU dual zone system typically uses two 9,000 BTU indoor units with an 18,000 BTU outdoor unit. Refer to the specific BTU ratings for your indoor units for exact dimensions.

9. Warranty and Support

Manufacturer's Warranty: The boreal BRISA system comes with a warranty of three (3) years on all parts and five (5) years on the compressor.

Warranty Eligibility: To be eligible for the manufacturer's warranty, installation must be performed by a state-licensed HVAC contractor. Proof of professional installation may be required for warranty claims.

For technical support, warranty claims, or to locate a licensed service provider, please refer to the contact information provided with your purchase documentation or visit the official boreal website.

Related Documents - MBRS18-W200

Preview BOREAL Kula R32 Split Air Conditioner Owner's Manual | Installation & Operation Guide
Comprehensive Owner's Manual for the BOREAL Kula R32 Split Air Conditioner. Includes installation, operation, safety precautions, maintenance, and troubleshooting guides for indoor units.
Preview BOREAL Split Air Conditioner INVERTER Owner's Manual
Comprehensive owner's manual for BOREAL Split Air Conditioner INVERTER models, covering installation, operation, safety precautions, maintenance, and troubleshooting.
Preview Boreal Split Air Conditioner INVERTER Owner's Manual
This owner's manual provides essential information for the safe operation, maintenance, and installation of the Boreal Split Air Conditioner INVERTER. It includes precautions, parts identification, operating guides, and troubleshooting tips.
Preview BOREAL Multi-Zone R32 Outdoor Unit Owner's Manual
This owner's manual from BOREAL details the installation, operation, maintenance, and safety of the Multi-Zone R32 outdoor unit air conditioner. Includes model information and troubleshooting.
Preview BOREAL brisa R32 Owner's Manual - Installation and Safety Guide
This owner's manual provides essential information for the BOREAL brisa R32 air conditioner outdoor unit, covering installation procedures, critical safety warnings, operational guidelines, and maintenance tips. It is designed for safe and efficient use of the product.
Preview Boreal Heat Pumps Exploded View and Parts List
Exploded view and parts list for Boreal Heat Pumps Ener Maxx R32 series, including outdoor and indoor units. Detailed part numbers and descriptions for models ENX24HPJ1320A, ENX36HPJ1320A, ENX48HPJ1320A, ENX60HPJ1320A, ENX24HPJ132AH, ENX36HPJ132AH, ENX48HPJ132AH, and ENX60HPJ132AH.