HBM Machines 7900 ATS Diesel Power Generator
HBM 7900 ATS Diesel Power Generator
User Manual
Model: 7900 ATS | Brand: HBM Machines
1. Introduction
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your HBM 7900 ATS Diesel Power Generator. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.
The HBM 7900 ATS Diesel Power Generator is a professional, powerful, and reliable silent diesel generator designed for various applications, including home, office, or construction site backup power. It features an electric start, automatic voltage regulation (AVR), and multiple output options.
2. Product Overview
2.1 Generator Components

Figure 2.1: Front-side view of the HBM 7900 ATS Diesel Power Generator, showing the main housing and control panel.

Figure 2.2: Side view of the generator with the access panel open, revealing the internal battery and engine components.
2.2 Control Panel

Figure 2.3: Detailed view of the control panel, featuring the digital display, starter switch, emergency stop, low oil pressure alarm, pre-heater, and various AC outlets (400V, 230V).
The control panel includes:
- Digital Panel: Displays operational parameters such as voltage, frequency, and hours.
- DC 12V 8.3A Output: For charging 12V batteries.
- Fuses: DC 12V 10A fuse for protection.
- Voltage Selector Switch: To select between 400V and 230V output.
- AC SW (Circuit Breakers): Overload protection for AC outputs.
- Starter Switch (OFF/ON/START): For electric starting the engine.
- Emergency Stop Button: Immediately shuts down the generator in an emergency.
- Low Oil Pressure Alarm: Indicator light for low oil level.
- Pre-Heater Button: Assists starting in cold weather.
- AC400V Outlet (PCE5p 16A): Three-phase power output.
- AC230V Outlet (32A): Single-phase power output.
3. Safety Instructions
WARNING: Failure to follow these safety instructions could result in serious injury or death.
3.1 General Safety
- Always operate the generator in a well-ventilated area to prevent carbon monoxide poisoning. Never operate indoors.
- Keep children and pets away from the generator during operation.
- Ensure the generator is placed on a level, stable surface.
- Do not operate the generator in rain or wet conditions.
- Wear appropriate personal protective equipment (PPE) such as gloves and eye protection.
3.2 Electrical Safety
- Never connect the generator directly to a building's electrical system without a proper transfer switch installed by a qualified electrician. Backfeeding can cause electrocution.
- Ensure all electrical connections are secure and free from damage.
- Do not overload the generator. Refer to the specifications for maximum load capacity.
- Use only approved extension cords that are rated for outdoor use and the appropriate amperage.
3.3 Fuel Safety
- Diesel fuel is highly flammable. Store fuel in approved containers in a cool, well-ventilated area, away from ignition sources.
- Never refuel the generator while it is running or hot. Allow the engine to cool down completely.
- Avoid spilling fuel. If spills occur, clean them up immediately.
- Do not smoke near the generator or fuel storage area.
4. Setup
4.1 Unpacking and Placement
- Carefully remove the generator from its packaging. Inspect for any shipping damage.
- Place the generator on a firm, level surface outdoors, at least 1 meter (3 feet) away from buildings and other equipment. Ensure adequate ventilation.
- Lock the wheels (if applicable) or ensure the generator cannot move during operation.
4.2 Initial Checks
- Check Engine Oil Level: The generator is shipped without engine oil. Fill with 15W-40 diesel engine oil to the upper mark on the dipstick. The oil capacity is 1650 ML.
- Check Fuel Level: Fill the fuel tank with clean diesel fuel. The fuel tank capacity is 12 liters. Do not overfill.
- Check Air Filter: Ensure the air filter is clean and properly installed.
- Battery Connection: Connect the battery terminals (if not already connected) ensuring correct polarity (red to positive, black to negative).
5. Operating Instructions
5.1 Starting the Generator (Electric Start)
- Ensure all loads are disconnected from the generator outlets.
- Turn the main circuit breaker (AC SW) to the 'OFF' position.
- If operating in cold weather, press and hold the Pre-Heater Button for 5-10 seconds.
- Insert the key into the Starter Switch and turn it to the 'ON' position.
- Turn the key further to the 'START' position and hold until the engine starts. Do not crank for more than 5 seconds at a time. If the engine does not start, wait 10 seconds before trying again.
- Once the engine starts, release the key, and it will return to the 'ON' position.
- Allow the engine to warm up for a few minutes before connecting any loads.
5.2 Connecting Electrical Loads
- After the generator has warmed up, select the desired voltage (400V or 230V) using the Voltage Selector Switch.
- Plug your electrical devices into the appropriate outlets (AC400V or AC230V).
- Turn the main circuit breaker (AC SW) to the 'ON' position.
- Connect loads one by one, starting with the largest load. Do not exceed the generator's rated output.
5.3 Stopping the Generator
- Disconnect all electrical loads from the generator outlets.
- Turn the main circuit breaker (AC SW) to the 'OFF' position.
- Allow the generator to run for a few minutes without load to cool down.
- Turn the Starter Switch key to the 'OFF' position.
- In an emergency, press the Emergency Stop Button to immediately shut down the engine.
6. Maintenance
Regular maintenance is crucial for the longevity and reliable operation of your generator.
6.1 Maintenance Schedule
| Item | Before Each Use | Every 50 Hours / Monthly | Every 200 Hours / 6 Months |
|---|---|---|---|
| Engine Oil Level | Check | Change | - |
| Fuel Level | Check | - | - |
| Air Filter | Check | Clean | Replace |
| Fuel Filter | - | - | Replace |
| Battery | Check terminals | Check charge | - |
6.2 Oil Change Procedure
- Run the engine for a few minutes to warm the oil.
- Shut down the engine and disconnect the spark plug wire (if applicable) or battery to prevent accidental starting.
- Place a suitable container under the oil drain plug.
- Remove the oil drain plug and allow the oil to drain completely.
- Reinstall the drain plug and refill with 1650 ML of fresh 15W-40 diesel engine oil.
- Check the oil level with the dipstick; do not overfill.
6.3 Storage
For long-term storage (more than 30 days):
- Drain the fuel tank or add a fuel stabilizer.
- Change the engine oil.
- Clean the air filter.
- Store the generator in a clean, dry, well-ventilated area.
- Disconnect the battery and store it in a cool, dry place, ensuring it is fully charged.
7. Troubleshooting
This section provides solutions to common operational issues. For problems not listed here, contact qualified service personnel.
| Problem | Possible Cause | Solution |
|---|---|---|
| Engine does not start | No fuel Low oil level Dead battery Faulty starter switch | Add diesel fuel Add engine oil Charge/replace battery Contact service |
| No power output | Circuit breaker tripped Overload Faulty outlet AVR malfunction | Reset circuit breaker Reduce load Contact service Contact service |
| Engine runs rough | Dirty air filter Contaminated fuel Low oil level | Clean/replace air filter Drain and refill fuel Check and add oil |
| Low oil alarm activates | Low oil level | Check oil level and add oil (engine will stop automatically) |
8. Specifications
| Feature | Specification |
|---|---|
| Model | 7900 ATS Diesel Power Generator |
| Engine Type | 4-stroke Diesel, 452CC (13 HP, Type D500E) |
| Cooling System | Air-cooled |
| Starting System | Electric Start |
| Rated Power (400V) | 6.3 kVA |
| Max Power (400V) | 7.0 kVA |
| Rated Power (230V) | 5.0 kVA |
| Max Power (230V) | 5.5 kVA |
| Output Voltage | 1 x 400V (PCE5p 16A), 1 x 230V (32A), 1 x 12V (8.3A) DC |
| Frequency | 50 Hz |
| Engine Speed | 3000 min-1 (RPM) |
| Fuel Type | Diesel |
| Fuel Tank Capacity | 12 Liters |
| Oil Type | 15W-40 |
| Oil Capacity | 1650 ML |
| Operating Capacity | Approx. 13 hours (at rated load) |
| Noise Level | 96 dB |
| Dimensions (L x W x H) | 92 x 52 x 76 cm |
| Weight | 152 kg |
| Special Features | Automatic Voltage Regulator (AVR), Low Oil Level Alarm with Auto Stop, Overload Protection, Direct Injection |
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your authorized HBM Machines dealer or the point of purchase. Keep your purchase receipt as proof of purchase for warranty claims.
Always refer to the official HBM Machines website or contact customer service for the most up-to-date warranty terms and conditions.
Ask a question about this manual