TEMPO 620K-G

TEMPO 620K-G Security and Alarm Tone and Probe Kit

Instruction Manual

1. Introduction

The TEMPO 620K-G Security and Alarm Tone and Probe Kit is a professional tool designed for the security and alarm industry. This kit facilitates reliable testing and identification of wires, cables, and intermittent failures within alarm circuits. It is engineered for efficiency, allowing for convenient one-person operation.

2. Product Overview and Components

The 620K-G kit includes a tone generator, a tone probe, and a carrying case, providing a comprehensive solution for circuit testing and wire tracing.

TEMPO 620K-G Security and Alarm Tone and Probe Kit components

Figure 1: The TEMPO 620K-G kit, showing the tone generator, tone probe, and carrying case.

Labeled components of the TEMPO 620K-G kit

Figure 2: Detailed view of the kit components, including the tone generator, tone probe, and carrying case, with key features highlighted.

2.1. What's in the Box

  • TEMPO 620 Tone Generator / Continuity Tester
  • TEMPO 200EP Tone Probe
  • Carrying Case
  • 1 x 9V Battery (pre-installed or included separately)

3. Key Features

  • Reliable Security Testing: Specifically designed for security and alarm applications, ensuring accurate testing and identification of issues in alarm circuits.
  • One-Person Operation: Features a high-volume audible indicator on the probe, enabling efficient testing and troubleshooting by a single technician.
  • Intermittent Fault Finding: A special latching feature assists in locating intermittent circuit faults, streamlining the identification and resolution of complex issues.
  • Secure and Convenient: The tone generator includes a magnetic backing for easy attachment to metal surfaces, such as alarm panel doors, ensuring stable placement during use.
  • Connection Versatility: Supports connections to either Normally Open (N.O.) or Normally Closed (N.C.) circuits.
  • Loop Pair Verification: Allows for verification of loop pairs.
  • Distinct Audible Tone: Provides a clear audible tone when an alarm condition occurs, aiding in quick diagnosis.
  • Switch Function Confirmation: Quickly confirms the proper function of switches.

4. Setup

4.1. Battery Installation

The TEMPO 620K-G requires one 9V battery for operation, which is included with the kit. To install or replace the battery:

  1. Locate the battery compartment on the back of the tone generator.
  2. Open the battery compartment cover.
  3. Connect a new 9V battery to the battery clip, observing correct polarity.
  4. Place the battery into the compartment and close the cover securely.

5. Operating Instructions

5.1. Tone Generation and Wire Tracing

To trace wires or cables using the tone generator and probe:

  1. Connect the tone generator to the wire or cable to be traced. Use the alligator clips for bare wires or the RJ11/RJ45 connector for modular jacks.
  2. Set the tone generator's slide switch to the 'TONE' position.
  3. Activate the tone probe and sweep it along the suspected path of the wire. The probe will emit an audible tone that increases in volume as it approaches the toned wire.
Technician using the tone probe to identify wires in a bundle

Figure 3: The tone probe in use, helping to identify specific wires within a larger bundle.

5.2. Continuity and Discontinuity Testing

The tone generator can also be used to test for continuity or discontinuity in circuits:

  1. Connect the tone generator across the two points of the circuit you wish to test.
  2. Set the slide switch to 'N.O.' (Normally Open) or 'N.C.' (Normally Closed) depending on the circuit type.
  3. If the circuit is continuous (closed for N.O., open for N.C.), the tone generator will emit a distinct audible tone.

5.3. Locating Intermittent Faults (Latching Feature)

The latching feature is crucial for identifying intermittent faults:

  1. Connect the tone generator to the circuit.
  2. Set the slide switch to 'N.O. LATCH' or 'N.C. LATCH'.
  3. The device will monitor the circuit. If an intermittent fault occurs (e.g., a momentary open in a normally closed circuit), the tone generator will latch onto that condition and continue to emit a tone, even if the fault clears.
  4. Press the 'RESET' button to clear the latched condition.
Close-up of the 6-position slide switch on the tone generator

Figure 4: The 6-position slide switch on the tone generator, used to select between OFF, TONE, N.O., N.O. LATCH, N.C., and N.C. LATCH modes.

5.4. Loop Pair Verification

The 620K-G supports loop pair verification to confirm circuit integrity:

  1. Connect the tone generator to one end of the loop pair.
  2. Use the appropriate setting (N.O. or N.C.) to test the continuity of the loop.
  3. A distinct tone indicates a complete and functional loop.

6. Maintenance

To ensure the longevity and optimal performance of your TEMPO 620K-G kit, follow these maintenance guidelines:

  • Cleaning: Wipe the devices with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Storage: Store the kit in its carrying case in a cool, dry place when not in use. Remove batteries if the device will not be used for an extended period to prevent leakage.
  • Battery Replacement: Replace the 9V battery when the audible tone becomes weak or the device fails to power on.

7. Troubleshooting

ProblemPossible CauseSolution
No tone from probeTone generator not powered on or battery low. Incorrect setting on tone generator. No connection to wire.Ensure tone generator is ON and set to 'TONE'. Replace 9V battery. Verify secure connection to the wire.
Weak or distorted toneLow battery in tone generator or probe. Interference from other electrical sources.Replace 9V battery in both units. Move away from strong electrical fields.
Latching feature not workingIncorrect mode selected. Fault not occurring or too brief.Ensure 'N.O. LATCH' or 'N.C. LATCH' is selected. Verify the fault condition.
Inaccurate continuity testPoor connection. Incorrect N.O./N.C. setting.Ensure solid connection points. Select the correct N.O. or N.C. mode for the circuit type.

8. Specifications

  • Model Number: 620K-G
  • Power Source: 9V Battery (included)
  • Item Weight: Approximately 16 ounces (0.45 kg)
  • Package Dimensions: 12.24 x 5.39 x 2.72 inches (31.1 x 13.7 x 6.9 cm)
  • Manufacturer: Tempo Communications
  • Date First Available: August 27, 2020

9. Warranty and Support

Tempo Communications products are designed for durability and reliability. For specific warranty information or technical support, please refer to the official Tempo Communications website or contact their customer service directly. Keep your purchase receipt for warranty claims.

For further assistance, please visit the Tempo Communications Store on Amazon.

Related Documents - 620K-G

Preview Tempo 200EP Inductive Amplifier User Manual
User manual for the Tempo 200EP Inductive Amplifier by Tempo. This guide covers safe operation, maintenance, features, and specifications for identifying and tracing wires and cables using the device with a tone generator.
Preview Tempo 200EP Inductive Amplifier Instruction Manual
This manual provides instructions for the safe operation and maintenance of the Tempo 200EP Inductive Amplifier, designed for identifying and tracing wires and cables.
Preview Roadmaps That Matter: A Guide to Strategic Planning and Execution
Learn how to create actionable roadmaps that align strategy with execution. This guide covers common challenges, best practices, and tools for effective roadmapping, from balancing priorities to measuring success.
Preview Tempo HP-3017 Wireless Headphones Instruction Manual
Get detailed instructions for your Tempo HP-3017 Wireless Headphones. This manual covers pairing, charging, specifications, safety, and troubleshooting for your Bluetooth audio experience.
Preview Tempo 11' Simple Gable Roof Shelter Specifications
Detailed specifications and dimensions for the Tempo 11' Simple Gable Roof Shelter, including height, width, and roof pitch measurements for various models.
Preview Tempo Mini Single-Slope Shelter Dimensions and Specifications
Comprehensive dimensions and specifications for Tempo Mini Single-Slope shelters, detailing measurements A, B, C, D, and E for various sizes. Essential information for selecting the right shelter.