1. Introduction

The Walfront ZT5566 is a high-accuracy digital multimeter designed for a wide range of electrical measurements. Featuring an auto-ranging 19999 count display, it provides precise readings for AC/DC voltage, current, resistance, capacitance, frequency, diode, and continuity tests. This multifunctional device also includes integrated Bluetooth audio, a clock, an alarm clock, and ambient temperature display, making it a versatile tool for professionals and hobbyists alike.

This manual provides detailed instructions on the proper use, setup, operation, and maintenance of your ZT5566 Digital Multimeter to ensure safe and accurate performance.

2. Safety Information

Always observe basic safety precautions when using this multimeter to prevent personal injury or damage to the meter or equipment under test. Read the following safety information carefully before use.

3. Package Contents

Verify that all items listed below are included in your package:

4. Product Overview

The ZT5566 Digital Multimeter features a robust design with a clear LCD display and intuitive controls for various measurement functions.

Walfront ZT5566 Digital Multimeter with test leads and USB cable

Figure 4.1: Walfront ZT5566 Digital Multimeter and Accessories. This image shows the main unit, two test leads (red and black), and a USB charging cable, providing a complete view of the product and its essential components.

Close-up of ZT5566 Multimeter front panel

Figure 4.2: Front Panel of the ZT5566 Multimeter. This close-up view highlights the large digital display, function buttons (V~Hz, mV~Hz, Ω, Diode/Continuity, Hold, Max/Min, Rel), and input jacks (VΩHz, COM, mA, A) for connecting test leads.

The device is equipped with a large LCD display for clear readings, function buttons for mode selection, and input terminals for test leads. It also features a circular display for clock/temperature and a speaker for audio output.

USB charging port on the back of the ZT5566 Multimeter

Figure 4.3: USB Charging Port. This image shows the micro-USB charging port located on the side/back of the multimeter, used for recharging the internal battery.

5. Setup

5.1 Battery Installation

The ZT5566 Multimeter requires 2 x AA batteries (not included) for operation. Ensure correct polarity when inserting batteries. The device also has a built-in rechargeable battery (4000mAH) that can be charged via the USB charging cable provided.

  1. Locate the battery compartment on the back of the multimeter.
  2. Open the battery cover.
  3. Insert 2 x AA batteries, observing the polarity markings (+ and -).
  4. Close the battery cover securely.
  5. For charging the internal battery, connect the USB charging cable to the multimeter's USB port and a suitable USB power source.

5.2 Connecting Test Leads

Always connect the black test lead to the 'COM' (Common) input jack. Connect the red test lead to the appropriate input jack based on the measurement you intend to perform:

Caution: Ensure test leads are correctly inserted into the appropriate jacks for the selected function to prevent damage to the meter or circuit.

6. Operating Instructions

The ZT5566 features an auto-ranging display and is designed for ease of use. The LCD display provides clear readings, and the backlight brightness is adjustable for optimal visibility.

ZT5566 Multimeter demonstrating various functions

Figure 6.1: Multimeter Functionality Overview. This image illustrates the multimeter performing various measurements including Frequency, Resistance, Capacitance, and Buzzer (Continuity) tests, showing the display for each function.

6.1 Basic Measurements

To perform a measurement, turn on the multimeter. The device will automatically select the appropriate range for most measurements (Auto Range). Select the desired function using the mode buttons.

Icons representing various multimeter functions

Figure 6.2: Full-Featured Icons. This graphic displays icons for all major functions: Voltage, Current, Resistance, Capacitance, Diode, Buzzer, Frequency, Music, Temperature, Time, and Alarm Clock, indicating the comprehensive capabilities of the device.

6.2 Special Features

Person using ZT5566 Multimeter while listening to music

Figure 6.3: Multimeter in Use with Music Playback. This image shows a user performing a measurement with the multimeter, while the device simultaneously plays music, illustrating its dual functionality for work and entertainment.

ZT5566 Multimeter connected wirelessly to a smartphone

Figure 6.4: Wireless Connection Feature. This image depicts the ZT5566 Multimeter alongside a smartphone, emphasizing its wireless connectivity for features like Bluetooth audio, enhancing user convenience.

7. Specifications

ParameterValue / Range
ModelZT5566
Display19999 Count, Auto Range
Working Power Supply2 x AA Batteries (Not Included)
Internal Battery TypeLithium Battery
Internal Battery Capacity4000mAH
DC Voltage (V)1.9999 V / 19.999 V / 199.99 V / 1000.0 V
DC Voltage (mV)19.999mV / 199.99mV
AC Voltage (V)1.9999 V / 19.999 V / 199.99 V / 750.0 V
AC Voltage (mV)19.999mV / 199.99mV
DC Current (A)1.9999A / 19.999A
DC Current (mA)19.999mA / 199.99mA
AC Current (A)1.9999A / 19.999A
AC Current (mA)19.999mA / 199.99mA
Resistance (Ω)199.99Ω / 1.9999kΩ / 19.999kΩ / 199.99kΩ / 1.9999MΩ / 19.999MΩ / 199.99MΩ
Capacitance (F)9.999nF / 99.99nF / 999.9nF / 9.999µF / 99.99µF / 999.9µF / 9.999mF
Frequency (Hz)99.99Hz / 999.9Hz / 9.999kHz / 99.99kHz / 999.9kHz / 6.000MHz
Bluetooth VersionV5.0
Bluetooth Distance≤10m / 32.8ft
Nominal Power (Audio)2x4 W RMS
Frequency Range (Audio)100Hz-18KHz
Distortion (Audio)≤1%
Signal to Noise Ratio (Audio)≥76dB
Work Environment Temperature0-40℃
Work Environment Humidity<75%
Storage Environment Temperature10-60℃
Storage Environment Humidity<80%

8. Maintenance

8.1 Cleaning

To clean the multimeter, wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the device is powered off and test leads are disconnected before cleaning.

8.2 Battery Replacement / Charging

If the display indicates low battery for the AA batteries, replace them as described in Section 5.1. For the internal rechargeable battery, connect the USB charging cable when the battery indicator shows low power.

8.3 Storage

When not in use for extended periods, remove the AA batteries to prevent leakage. Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures.

9. Troubleshooting

If you encounter issues with your ZT5566 Multimeter, refer to the following common troubleshooting tips:

If the problem persists after attempting these steps, please contact customer support.

10. Warranty and Support

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official Walfront website. Keep your purchase receipt as proof of purchase for any warranty claims.

Related Documents - ZT5566

Preview 部品/規格/技術ノート - 農業向けアクティブ・デバイス
Interface誌掲載の部品/規格/技術ノート。農業における害獣・人検出センサー(焦電、ドップラー、超音波)やアクティブ・デバイスに関する技術情報と製品仕様を解説。