RENOGY RNG-DCC1212-60-JP

Renogy DC-DC 12V 60A Battery Charger Instruction Manual

Model: RNG-DCC1212-60-JP

1. Safety Information

Please read all instructions and warnings in this manual carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury. Keep this manual for future reference.

  • Always wear appropriate personal protective equipment, including eye protection, when working with batteries and electrical systems.
  • Ensure all connections are tight and secure to prevent loose connections that can cause excessive heat and damage.
  • Do not operate the charger in wet or damp conditions.
  • Ensure adequate ventilation around the charger to prevent overheating.
  • Disconnect all power sources before performing any maintenance or troubleshooting.
  • Do not attempt to disassemble or repair the charger yourself. Contact qualified service personnel.

2. Product Overview

2.1 Key Features

  • Versatile Battery Compatibility: The Renogy DC-DC charger is compatible with multiple alternator types and sub-battery types, including AGM, flooded, gel, and lithium-ion batteries.
  • Smart 3-Stage Charging: This battery charger charges the sub-battery from the starter battery using a 3-stage charging process (bulk, boost, float), ensuring optimal and automatic 100% charge.
  • Main Battery Over-Discharge Protection: The DC-DC battery charger identifies whether the generator is running, preventing over-discharge of the starter battery and protecting the main battery.
  • Enhanced Safety: Provides over-voltage protection, over-temperature protection, and reverse polarity protection, ensuring safe operation. It also isolates input and output to prevent voltage transmission errors and protect the house battery from overcharging.
  • Durable Design: Features a compact and robust construction for reliable performance.

2.2 Product Dimensions

Renogy DC-DC Charger with dimensions: 31.1 cm length, 17.5 cm width, 6.8 cm height

The image above shows the Renogy DC-DC Charger with its dimensions: 31.1 cm length, 17.5 cm width, and 6.8 cm height.

2.3 Parts Description

Diagram of Renogy DC-DC Charger ports and indicators

This diagram illustrates the various ports and indicators on the Renogy DC-DC Charger.

#MarkDescription
1Input (+)Main Battery Positive
2Input (-)Main Battery Negative
3Power IndicatorPower Indicator LED
4Error IndicatorError Indicator LED
5S1 S2 S3 S4 S5Battery Type Setting Switch (DIP Switches)
6RJ11Temperature Sensor Connection Port
7D+Signal Line Connection Port
8LCCurrent Limit Port
9Output (+)Sub-battery Positive
10Output (-)Sub-battery Negative

3. Setup and Installation

3.1 Connection Diagram

Wiring diagram for Renogy DC-DC Charger connecting to main and sub-batteries in an RV

This diagram illustrates the wiring connections for the DC-DC Charger in a typical RV setup, connecting to both the main (starter) battery and the sub-battery (house battery).

  • DC-DC Charger ↔ Main Battery Wiring
  • DC-DC Charger ↔ Sub-battery Wiring
  • DC-DC Charger D+ Port ↔ Alternator D+ Terminal Wiring

Note: All wiring requires separate purchase. Cables are not included with this product; please prepare them separately if needed.

3.2 DIP Switch Settings

DIP switch settings for Renogy DC-DC Charger to adjust battery type and charging voltage

The image shows the DIP switches used to configure the charger. By operating the 5 switches (S1-S5), you can adjust the battery type and charging voltage.

  • S1 and S2: Set Absorption Voltage
  • S3 and S4: Set Float Charge Voltage
  • S5: Set Charging Mode

3.3 Cable Size Selection

Table showing recommended cable sizes and fuse ratings for different DC-DC charger models

Refer to this table for recommended cable sizes and fuse ratings based on your specific DC-DC charger model and cable length.

ModelCableMinimum Cable SizeFuse
DCC-1212-20Main Battery0.61m 5.5sq2.44m 5.5sq4.88m 8.0sq9.75m 22sq30A
Sub-battery0.61m 3.5sq2.44m 3.5sq4.88m 5.5sq9.75m 14sq25A
DCC-1212-40Main Battery0.61m 14sq2.44m 14sq4.88m 22sq9.75m 38sq60A
Sub-battery0.61m 8.0sq2.44m 8.0sq4.88m 14sq9.75m 22sq50A
DCC-1212-60Main Battery0.61m 22sq2.44m 22sq90A
Sub-battery0.61m 14sq2.44m 14sq4.8m 22sq75A
D+/LC0.75~1.2SQ

3.4 D+ and LC Ports

Close-up of D+ and LC ports on Renogy DC-DC Charger

The image highlights the D+ and LC ports on the charger.

  • D+ Port: Connects to the alternator's D+ terminal for smart alternator detection.
  • LC Port: By connecting to the LC port, the charging current can be limited by half. (Recommended cable size: 0.75~1.2SQ)

4. Operation

4.1 3-Stage Charging Process

Graph illustrating the 3-stage charging process: Bulk, Absorption, and Float

The graph above illustrates the 3-stage charging process (Bulk, Absorption, Float) that fully charges the battery.

  • Bulk: Charges the battery at the maximum current until it reaches a set voltage.
  • Absorption: Charges at a constant voltage, reducing current as the battery approaches full charge.
  • Float: Maintains the battery at a constant, lower voltage to prevent self-discharge.

4.2 LED Indicators

The charger features LED indicators to communicate the charging status and battery type. Refer to the tables below for detailed explanations.

Battery Type Indicator
ColorStatusDescription
GreenONSLA (Default)
YellowONGEL
RedONFLD (Flooded)
BlueONLI (Lithium)
WhiteONUser (Requires BT-2 Module and Renogy DC Home App)
Service Battery Indicator
ColorStatusDescription
GreenONBattery Full
YellowONBattery voltage normal
RedONBattery undervoltage
RedSlow FlashingBattery over discharged
RedFast FlashingBattery over voltage/over temperature

Note: The Charging Indicator may change under the following conditions:

  1. Red to Yellow: When the voltage reaches 12.2V under voltage recovery.
  2. Yellow to Red: When the voltage drops to 12.0V under voltage warning.
  3. Yellow to Green: A. When it reaches constant voltage charging state, the charging current is smaller than 3A, lasts for 30 seconds; B. When the charging current is higher than 3A, it keeps charging until it reaches constant voltage state and the current drops below 3A, lasts 30 seconds.
Alternator/Charging Indicator
ColorStatusDescription
GreenONAlternator is charging the service battery
RedSlow FlashingPV is charging the starting battery
OFFNot charging

4.3 Alternator Type and Starting Battery Voltage

Alternator TypeStarting Battery Voltage
Cut-inCut-off
Traditional Alternator>13.2V, for 15 seconds<12.7V
Smart Alternator>12.0V, for 15 seconds<11.5V

4.4 Charging Current Distribution (Solar + Alternator)

ModelRBC30DISRBC50DIS
Only Solar30A50A
Only Alt30A50A
Solar + ALT15A + 15A25A + 25A

When using both solar and alternator inputs, the current is split. For example, the RBC30DIS model will provide 15A from solar and 15A from the alternator, totaling 30A.

5. Maintenance

Regular maintenance ensures optimal performance and longevity of your Renogy DC-DC Charger.

  • Periodically check all wiring connections for tightness and corrosion. Clean any corroded terminals.
  • Inspect the charger for any physical damage or signs of overheating.
  • Ensure the area around the charger is free from dust and debris to maintain proper ventilation.
  • Verify that the battery type settings are correct for your installed batteries.

6. Troubleshooting

If you encounter issues with your DC-DC Charger, refer to the following basic troubleshooting steps:

  • No Power/LEDs Off: Check all battery connections and fuses. Ensure the starter battery voltage is above the cut-in threshold.
  • Error Indicator On: Refer to the LED Indicators section (4.2) for the specific error type (over-voltage, over-temperature, reverse polarity, etc.) and take corrective action.
  • Battery Not Charging: Verify that the correct battery type is selected using the DIP switches. Check solar panel connections and output, and ensure the alternator is functioning correctly.
  • Reduced Charging Current: Ensure the LC port is not connected if full current is desired. Check cable sizes against recommendations in section 3.3.

For persistent issues, please contact Renogy customer support.

7. Specifications

SpecificationValue
BrandRENOGY
ColorBlack
Product Dimensions (D x W x H)17.5 x 31.1 x 6.8 cm
Output Voltage12 Volts
Compliance StandardsCE, RoHS
Rated Current60 Amps
Manufacturer Model NumberRNG-DCC1212-60-JP
GTIN (Global Trade Identification Number)00810009715924
UPC810009715924
Product TypeDC-DC Charger
Included ComponentsJapanese Instruction Manual, DC-DC Charger Unit

8. Official Product Video

This video provides a visual guide on how to install and connect the Renogy DC-DC MPPT Charger, demonstrating connections to a starter battery, a lithium house battery, and a solar panel. It also covers setting battery types and understanding LED indicators for charging status.

9. Warranty and Support

This product comes with a 1-year manufacturer's warranty.

For any questions or support regarding your Renogy DC-DC Charger, please contact our customer service team:

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.