1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Summit Appliance ARS49ML Pharma-Vac Performance Series Refrigerator. Please read this manual thoroughly before operating the appliance and retain it for future reference.
The ARS49ML is a 49 cu.ft. upright pharmacy all-refrigerator designed for demanding life science, vaccine, laboratory, and medical cold storage applications, ensuring precise temperature control and stability.
2. Safety Information
WARNING: To reduce the risk of fire, electric shock, or injury when using your appliance, follow these basic precautions:
- Read all instructions before using the appliance.
- Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
- This appliance must be properly installed and located in accordance with the Installation Instructions before it is used.
- Connect to a properly grounded outlet only. See 'Grounding Instructions' in the installation section.
- Never unplug your appliance by pulling on the power cord. Always grasp the plug firmly and pull straight out from the outlet.
- Unplug your appliance before cleaning or making any repairs.
- Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
- Do not damage the refrigerant circuit.
- Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer.
- Ensure proper ventilation around the unit.
3. Product Overview
The Summit Appliance ARS49ML features a robust stainless steel exterior and interior, designed for durability and easy cleaning. It includes a sophisticated digital temperature controller and optimized forced air cooling for superior performance.




4. Installation
4.1 Location
Choose a location with a strong, level floor capable of supporting the refrigerator's weight (410 lbs. empty, plus contents). Ensure adequate air circulation around the unit. Avoid direct sunlight or heat sources. Maintain at least 4 inches of clearance from walls at the back and sides for proper ventilation.
4.2 Leveling
The refrigerator is equipped with wheels for easy movement. Once in its final position, ensure the unit is level to prevent door misalignment and ensure proper operation. Use a level and adjust the leveling feet (if present, or use shims under wheels if necessary) until the appliance is stable and level.
4.3 Electrical Connection
Before plugging in the appliance, ensure the electrical supply matches the specifications: 115V AC/60Hz, 7.5 Amps. The appliance must be properly grounded to reduce the risk of electrical shock. Do not use extension cords or ungrounded adapters.
4.4 Initial Startup
After installation, allow the refrigerator to stand upright for at least 2-4 hours before plugging it in. This allows the refrigerant to settle. Once plugged in, allow the unit to operate empty for several hours (e.g., 24 hours) to reach its stable operating temperature before loading products.
5. Operation
5.1 Digital Temperature Controller
The ARS49ML features an intelligent microprocessor digital temperature controller. The operating control range is adjustable from +2°C to +10°C (+35.6°F to +50°F).
- Temperature Display: The digital display shows the current internal temperature. It can be viewed in Celsius or Fahrenheit to the nearest degree.
- Min/Max Temperature: The controller tracks and displays the minimum and maximum temperatures recorded, updated in 15-minute increments. Consult the controller's specific instructions for accessing min/max readings.
- Temperature Probe: A separate temperature probe provides continuous product readout for improved accuracy. An additional sensor reads interior air temperature for superior control.
5.2 Temperature Adjustment
Refer to the specific instructions provided with the digital controller for detailed steps on how to adjust the set temperature. Generally, this involves pressing a 'SET' button and using arrow keys to increase or decrease the desired temperature.
5.3 Alarms
The unit is equipped with audible and visual alarms for high/low temperature excursions. If an alarm sounds, check the temperature display and take appropriate action to correct the issue. Consult the controller's manual for alarm silencing and reset procedures.
5.4 Forced Air Cooling
The optimized forced air cooling system ensures excellent temperature stability and uniformity throughout the cabinet. This system also facilitates rapid temperature recovery after door openings and product loading, minimizing temperature fluctuations.

5.5 Loading Products
When loading products, distribute them evenly on the wire shelves to allow for proper air circulation. Avoid blocking the air vents. The adjustable shelves allow for flexible storage configurations.


6. Maintenance
6.1 Cleaning
Regular cleaning of your refrigerator will help maintain its appearance and efficiency. Always unplug the unit before cleaning.
- Interior: Clean the interior surfaces and wire shelves with a mild detergent and warm water solution. Rinse thoroughly and dry with a soft cloth. Do not use abrasive cleaners or sharp objects.
- Exterior: Wipe down the stainless steel exterior with a soft cloth and a stainless steel cleaner or mild soap and water. Avoid harsh chemicals that can damage the finish.
- Condenser Coils: Periodically clean the condenser coils (located at the bottom/rear of the unit) to ensure efficient operation. Use a vacuum cleaner or brush to remove dust and debris.
6.2 Defrosting
The ARS49ML features an automatic defrost system. This means that frost buildup on the evaporator coils is periodically melted and drained, eliminating the need for manual defrosting. Ensure the drain pan is clear and not obstructed.
7. Troubleshooting
Before contacting customer service, please check the following common issues:
| Problem | Possible Cause | Solution |
|---|---|---|
| Refrigerator does not operate | Not plugged in; Circuit breaker tripped/fuse blown; Power switch off | Ensure plug is secure; Reset breaker/replace fuse; Turn power switch on |
| Temperature is too warm | Door left open; Door gasket faulty; Excessive door openings; Unit overloaded; Poor ventilation; Set temperature too high | Close door fully; Check/replace gasket; Reduce door openings; Do not overload; Ensure proper clearance; Adjust set temperature lower |
| Excessive noise | Unit not level; Objects vibrating against unit; Fan obstruction | Level the unit; Remove vibrating objects; Check for fan obstruction |
| Alarm sounding | High/low temperature excursion; Door ajar | Check temperature and product integrity; Ensure door is fully closed; Consult controller manual for alarm reset |
8. Specifications
| Feature | Specification |
|---|---|
| Model | ARS49ML |
| Brand | Accucold (Summit Appliance) |
| Capacity | 49 cu.ft. |
| Dimensions (H x W x D) | 83.75" x 55.25" x 31" |
| Depth with Handle | 32.75" |
| Depth with door at 90° | 56.5" |
| Interior Dimensions (H x W x D) | 51.5" x 50.5" x 27" |
| Weight (Net/Shipping) | 410 lbs. / 430 lbs. |
| Defrost Type | Automatic |
| Door/Cabinet Material | Stainless Steel |
| Electrical (Voltage/Frequency/Amps) | 115V AC / 60Hz / 7.5A |
| Thermostat Type | Digital |
| Refrigerant Type | R290a |
| Shelf Type / Quantity | Wire / 8 (Adjustable) |
| Safety Certifications | UL, ULC, ETL-S |
| Wheels | 4 |
9. Warranty and Customer Support
For warranty information and customer support, please refer to the documentation provided with your purchase or visit the official Accucold/Summit Appliance website. For immediate assistance, you may contact the seller, VetSupplyOnline, through the Amazon platform. Please retain your proof of purchase for any warranty claims.
Returns: This product is eligible for 30-day easy returns as per Amazon's policy.