Introduction
This manual provides essential information for the safe and efficient use of the Jiayin JYPC-2 Electromagnetic Solenoid Water Pump. This pump is designed for various applications requiring precise fluid delivery, such as electric irons, steam mops, garment steamers, and coffee machines. Please read these instructions thoroughly before installation, operation, or maintenance to ensure proper function and safety.
Safety Information
- Electrical Hazard: This pump operates on AC 110V-120V. Ensure power is disconnected before any installation, maintenance, or troubleshooting. Only qualified personnel should perform electrical connections.
- Liquid Compatibility: Use only with water or non-corrosive liquids as specified. Using incompatible liquids may damage the pump and void the warranty.
- Temperature Limits: Adhere to the specified ambient temperature (Ta 70°C / 158°F) and medium temperature (Tf 60°C / 140°F) to prevent overheating and damage.
- Proper Installation: Ensure the pump is securely mounted and all connections are tight to prevent leaks and ensure stable operation.
- Ventilation: Ensure adequate ventilation around the pump to prevent heat buildup.
- Children and Pets: Keep the pump and associated equipment out of reach of children and pets.
Product Overview
The Jiayin JYPC-2 is a compact electromagnetic solenoid pump designed for reliable and consistent fluid transfer. Its robust construction ensures durability and performance in various household and commercial appliances.

Figure 1: Overall view of the JYPC-2 pump with integrated technical data and dimensional drawings.
Key Features:
- No rust, no clogging, ensuring clear fluid path.
- Operates on AC 110V - 120V, 60Hz, 16W.
- Flow rate of 90cc/min (with a tolerance of ±10%).
- Suitable for water or non-corrosive liquids.
- Designed for ambient temperatures up to 70°C (158°F) and medium temperatures up to 60°C (140°F).
Specifications

Figure 2: Detailed dimensions of the JYPC-2 pump.
| Parameter | Value |
|---|---|
| Brand | Jiayin |
| Model | JYPC-2 |
| Type | Miniature Electromagnetic Pump |
| Voltage | AC 110V-120V |
| Frequency | 60Hz |
| Power | 16W |
| Flow Rate | 90cc/min (±10%) |
| Working Pressure | 0-3 bar |
| Ambient Temperature (Ta) | Up to 70°C (158°F) |
| Medium Temperature (Tf) | Up to 60°C (140°F) |
| Weight | 116g / 4.1oz (approx. 3.21 ounces) |
| Material | Plastic |
| Product Dimensions (L x W x H) | 3.1" x 1.5" x 1.3" (approx. 78.5mm x 38mm x 33mm) |
| Driving Method | Magnetic Force |
| Working Medium | Water or non-corrosive liquid |
Setup and Installation
Proper installation is crucial for the safe and efficient operation of the JYPC-2 pump. If you are unsure about any steps, consult a qualified technician.

Figure 3: Detailed view of the JYPC-2 pump, highlighting connections.
- Disconnect Power: Always ensure the power supply to the appliance or system is completely disconnected before beginning installation.
- Identify Connections: Locate the fluid inlet and outlet ports on the pump. The pump typically has a designated inlet and outlet, often indicated by arrows or specific hose barb sizes. The electrical terminals are clearly visible on the coil housing.
- Mounting: Securely mount the pump in the intended location. Ensure it is stable and free from excessive vibration. The pump's metal chassis may require specific grounding, depending on the application.
- Fluid Connections: Connect the appropriate hoses to the inlet and outlet ports. Ensure all hose clamps or connectors are tight to prevent leaks. The flow test method specifies a 13.8-inch silicon tube with an outer diameter of 0.28 inches and an inner diameter of 0.14 inches for the water inlet port.
- Electrical Wiring: Connect the pump's electrical terminals to the appliance's power supply (AC 110V-120V, 60Hz). Pay close attention to polarity if specified by the appliance manufacturer. Ensure all electrical connections are secure and insulated.
- System Integration: Integrate the pump into the overall fluid system of the appliance (e.g., coffee machine, steam mop). Ensure there are no kinks in the tubing and that the fluid path is clear.
- Initial Check: Before restoring power, double-check all connections (fluid and electrical) for security and correctness.
Operation
The JYPC-2 pump operates automatically when power is supplied, initiating fluid transfer based on the appliance's control system. It is designed for intermittent or continuous duty as required by the application.
- Power On: Once installed and connected, restore power to the appliance. The pump will activate according to the appliance's operational cycle.
- Fluid Supply: Ensure a continuous and adequate supply of the specified working medium (water or non-corrosive liquid) to the pump's inlet. Running the pump dry can cause damage.
- Monitoring: During initial operation, observe the pump for any unusual noises, leaks, or signs of malfunction. The pump is designed to operate with minimal noise (38 dB).
- Flow Rate: The pump is rated for a flow rate of 90cc/min. Actual flow may vary slightly depending on system pressure and fluid viscosity.
Maintenance
The Jiayin JYPC-2 pump is designed for low maintenance. Regular checks can help ensure its longevity and optimal performance.
- Regular Inspection: Periodically inspect the pump and all connections for any signs of wear, damage, or leaks.
- Cleanliness: Ensure the pump and surrounding area are kept clean and free from debris that could obstruct airflow or contaminate the fluid system.
- Fluid Quality: Use clean, filtered water or specified non-corrosive liquids to prevent internal clogging or damage to pump components. The pump is designed to prevent rust and clogging.
- Storage: If the pump is to be stored for an extended period, ensure it is drained of any liquid and stored in a dry, temperate environment.
Troubleshooting
Before attempting any troubleshooting, ensure the power supply is disconnected. If the issue persists after following these steps, contact customer support or a qualified technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not operate / No flow |
|
|
| Reduced flow rate |
|
|
| Loud or unusual noise |
|
|
| Leaks |
|
|
Warranty Information
Specific warranty terms for the Jiayin JYPC-2 pump are typically provided by the seller or manufacturer at the time of purchase. Please refer to your purchase documentation or contact the retailer for detailed warranty coverage and procedures. Generally, warranties cover defects in materials and workmanship under normal use.
Note: Unauthorized modifications, improper installation, or use with incompatible liquids may void the product warranty.
Customer Support
For technical assistance, replacement parts, or further inquiries regarding your Jiayin JYPC-2 pump, please contact the retailer from whom you purchased the product. You may also visit the official Jiayin website for additional resources or contact information.
When contacting support, please have the following information ready:
- Product Model: JYPC-2
- Date of Purchase
- Description of the issue