1. Product Overview
The Solight GSM Socket DY10GSM is a remote-controlled power outlet designed to manage electrical appliances in your home or office. It allows you to switch power on or off using SMS commands or a dedicated mobile application. Beyond simple remote control, the unit integrates a temperature sensor for thermostat functions and provides an alarm in case of power outages or significant temperature deviations. This device can be expanded to control multiple outlets.
2. Key Features
- Remote Control: Manage connected appliances via SMS or mobile application.
- Temperature Sensor: Monitors ambient temperature.
- Thermostat Function: Automatically controls power based on set temperature ranges.
- Power Outage Alarm: Notifies you of power failures.
- Expandability: Supports up to four additional DY10S sockets for controlling up to five outputs individually with one SIM card.
- Scheduling: Program power on/off times.
- High Power Capacity: Supports appliances up to 16A or 3600W.
3. Package Contents
- 1x Solight GSM Remote Controlled Power Socket DY10GSM
- 1x User Manual
4. Safety Information
- Read all instructions before use.
- Do not disassemble or modify the device.
- Ensure the device is connected to a properly grounded power outlet.
- Do not exceed the maximum load of 16A / 3600W.
- Keep away from water and high humidity.
- This device is for indoor use only.
- Unplug the device from the power source before cleaning.
5. Setup
5.1 Inserting the SIM Card
- Locate the SIM card slot on the side of the DY10GSM unit.
- Ensure the device is unplugged from the power outlet.
- Insert a standard size (2FF) activated GSM SIM card into the slot, ensuring correct orientation. The SIM card should not have a PIN code enabled.
- Close the SIM card slot cover securely.
5.2 Initial Power-Up
- Plug the DY10GSM unit into a standard electrical wall outlet.
- The power indicator light (usually green) will illuminate.
- The GSM signal indicator light (usually blue) will flash as it searches for a network. Once connected, it will either glow steadily or flash slowly, depending on the model's specific indication for network connection.
Figure 1: Front view of the Solight DY10GSM socket, showing the power and signal indicator lights.
5.3 Pairing and Configuration
The first phone number to send an SMS command to the DY10GSM will automatically be registered as the administrator number. This number has full control over the device.
- Administrator Registration: Send any valid command (e.g., 'STATUS') via SMS to the SIM card number in the DY10GSM. The device will reply, confirming your number as the administrator.
- Mobile Application: Download the official Solight mobile application (if available) from your smartphone's app store. Follow the in-app instructions to add and configure your DY10GSM device.
6. Operating Instructions
6.1 Remote Control via SMS
Send the following commands via SMS to the SIM card number in the DY10GSM:
- Turn ON: Send 'ON'
- Turn OFF: Send 'OFF'
- Check Status: Send 'STATUS' (provides current power state, temperature, and signal strength).
- Set Thermostat: Send 'TEMP_ON_X_Y' to turn on when temperature is below X and off when above Y. (e.g., 'TEMP_ON_18_22' for 18-22°C).
- Disable Thermostat: Send 'TEMP_OFF'
- Set Schedule: Refer to the full SMS command list in the detailed manual for complex scheduling commands.
6.2 Remote Control via Mobile Application
Once the mobile application is installed and your device is added, you can control the socket through its intuitive interface. The app typically offers:
- One-touch ON/OFF control.
- Real-time temperature display.
- Thermostat settings and scheduling.
- Power outage notifications.
- Management of additional DY10S sockets.
6.3 Power Outage Alarm
The DY10GSM will send an SMS notification to the administrator number if it detects a power failure. It will also send a notification when power is restored.
6.4 Expanding with DY10S Sockets
The DY10GSM can control up to four additional DY10S sockets. These expansion sockets are controlled via the main DY10GSM unit. Refer to the DY10S manual for specific pairing and control instructions, typically involving SMS commands from the DY10GSM administrator phone to assign and control each DY10S unit.
Figure 2: Back view of the Solight DY10GSM socket, illustrating the electrical plug for connection to a wall outlet.
7. Maintenance
- Cleaning: Disconnect the device from power before cleaning. Use a soft, dry cloth. Do not use liquid or aerosol cleaners.
- Storage: Store the device in a cool, dry place when not in use.
- SIM Card: Periodically check the SIM card's credit balance to ensure continuous operation, especially for SMS-based commands and notifications.
8. Troubleshooting
- Device not responding to SMS:
- Check if the SIM card has sufficient credit.
- Ensure the SIM card does not have a PIN code enabled.
- Verify GSM signal strength (blue indicator light).
- Confirm you are sending commands from the registered administrator number.
- Check for correct SMS command syntax.
- Power indicator not on:
- Ensure the wall outlet has power.
- Check if the device is properly plugged in.
- Temperature readings are inaccurate:
- Ensure the device is not placed near heat sources or in direct sunlight.
- Allow time for the sensor to stabilize after initial power-up.
9. Specifications
| Model: | DY10GSM |
| Article Number: | 260849 |
| Brand: | Solight |
| Max Load: | 16A / 3600W |
| Control Method: | SMS, Mobile Application |
| Features: | Temperature Sensor, Thermostat, Power Outage Alarm, Scheduling |
10. Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official Solight website. Keep your proof of purchase for any warranty claims.