1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Mapei Thermo Basic Non-Programmable Floor Heating Thermostat (Model 2855401). This thermostat is designed to provide precise and consistent temperature control for electric radiant floor heating systems, enhancing comfort in your living or commercial space. Its non-programmable functionality ensures straightforward and hassle-free temperature management.

Mapei Thermo Basic Non-Programmable Floor Heating Thermostat

Figure 1: Front view of the Mapei Thermo Basic Non-Programmable Floor Heating Thermostat. The display shows "11:15" and "84°F", indicating the current time and temperature. Below the display, the "nVent NUHEAT" logo is visible, along with a square button.

2. Important Safety Information

WARNING: Electrical shock hazard. Installation must be performed by a qualified electrician in accordance with local and national electrical codes. Failure to follow these instructions may result in serious injury or death.

3. Key Features

4. Technical Specifications

AttributeDetail
BrandMapei
Model Number2855401 (Item model number: 94554-01)
Controller TypeNon-Programmable Thermostat
Voltage Compatibility120 V, 240 V
Special FeatureBuilt-in GFCI
ColorWhite
Specific UsesFloor Heating
Temperature Control TypeManual
Included ComponentsTemperature Sensor
Item Weight1 Pound (approx. 0.45 kg)
MaterialMetal, Plastic
Display TypeLED or LCD (Backlit)
Control TypeButton Control
Mounting TypeWall Mount
Dimensions6 x 3.5 x 2.75 inches (Package Dimensions)
ManufacturernVent

5. Installation

Installation of the Mapei Thermo Basic thermostat involves working with electrical wiring. For safety and proper functionality, it is strongly recommended that installation be performed by a qualified and licensed electrician in accordance with all local and national electrical codes.

5.1 Pre-Installation Checklist

5.2 Wiring Instructions

  1. Turn off power at the circuit breaker.
  2. Carefully remove the existing thermostat (if applicable) or the cover plate from the electrical box.
  3. Connect the thermostat wires to the appropriate electrical supply and floor heating cable wires. Refer to the wiring diagram provided with your specific product packaging for detailed connections. Ensure proper grounding.
  4. Install the included floor temperature sensor cable into the floor according to the floor heating system manufacturer's instructions. Connect the sensor wires to the designated terminals on the thermostat.
  5. Mount the thermostat securely into the electrical box.
  6. Restore power at the circuit breaker.

Note: Specific wiring diagrams and detailed installation steps are typically included in the product packaging. Always consult those instructions for your exact model.

6. Initial Setup

After successful installation and power restoration, the thermostat will power on.

  1. Initial Display: The display will typically show the current time and the measured floor temperature.
  2. Set Time (if applicable): If the thermostat has a clock display, use the designated buttons (usually up/down arrows or a menu button) to set the current time. Refer to the quick start guide in the product packaging for specific button functions.
  3. GFCI Test: Press the "TEST" button on the GFCI. The GFCI should trip, and the display may show an error code or turn off. Press the "RESET" button to restore power. If the GFCI does not trip or reset, consult the troubleshooting section or a qualified electrician.

7. Operation

The Mapei Thermo Basic is a non-programmable thermostat, meaning it maintains a set temperature manually adjusted by the user.

7.1 Setting the Temperature

7.2 GFCI Test and Reset

8. Maintenance

The Mapei Thermo Basic thermostat requires minimal maintenance.

9. Troubleshooting

If you encounter issues with your Mapei Thermo Basic thermostat, refer to the following common problems and solutions.

ProblemPossible CauseSolution
Thermostat display is blank.No power to the thermostat; tripped circuit breaker; loose wiring connection.Check the circuit breaker and reset if tripped. Ensure all wiring connections are secure (consult a qualified electrician).
Floor heating system is not heating.GFCI tripped; setpoint temperature is too low; heating cable issue.Press the GFCI RESET button. Increase the setpoint temperature. If the issue persists, consult a qualified electrician or the heating cable manufacturer.
GFCI trips frequently.Ground fault in the heating system; faulty GFCI.This indicates a serious electrical issue. Immediately contact a qualified electrician to diagnose and repair the fault. Do not attempt to bypass the GFCI.
Incorrect temperature reading.Faulty floor sensor; sensor not properly installed.Ensure the floor sensor is correctly installed and connected. If the problem persists, the sensor may need replacement (contact support).

For issues not listed above or if troubleshooting steps do not resolve the problem, please contact Mapei customer support or a qualified professional.

10. Warranty Information

The Mapei Thermo Basic Non-Programmable Floor Heating Thermostat is backed by a manufacturer's limited three-year warranty. This warranty is valid from the date of purchase and covers defects in materials and workmanship under normal use.

For full details regarding warranty terms, conditions, and claim procedures, please refer to the warranty documentation included with your product packaging or visit the official Mapei website. Keep your proof of purchase for warranty claims.

11. Customer Support

If you require further assistance with your Mapei Thermo Basic thermostat, including technical support, troubleshooting beyond this manual, or warranty inquiries, please contact Mapei customer service.

You can typically find contact information (phone number, email, or support portal) on the official Mapei website or within the product packaging.

Online Resources: For additional information and resources, you may visit the Mapei Store on Amazon or the official Mapei website.

Related Documents - 2855401

Preview Mapei Mapelastic AquaDefense Zero: Flexible Waterproofing Membrane for Interior & Exterior Surfaces
Discover Mapei Mapelastic AquaDefense Zero, a ready-to-use, quick-drying, flexible liquid membrane for waterproofing bathrooms, balconies, and more. Learn about its features, application, and technical specifications.
Preview MAPEI Ultrabond Eco VS60: Multifunktioneller Dispersionsklebstoff für Boden- und Wandbeläge
Technisches Datenblatt für MAPEI Ultrabond Eco VS60, ein Dispersionsklebstoff mit hoher Anfangshaftung für PVC-, Textil-, Linoleum- und Designbeläge an Böden und Wänden. Enthält Anwendungs-, technische und Sicherheitshinweise.
Preview MAPEI Flexcolor 4 LVT: Ready-to-Use Grout for Luxury Vinyl Tile
Technical data sheet for MAPEI Flexcolor 4 LVT, a ready-to-use grout formulated with fine aggregate for luxury vinyl tile (LVT) and luxury vinyl plank (LVP) installations. Details features, benefits, application, limitations, and technical specifications.
Preview MAPEI Megalite S2 Quick: High-Performance Flexible Tile Adhesive - Technical Data
Technical data sheet for MAPEI Megalite S2 Quick, a one-component, flexible, lightweight, rapid-hardening cementitious tile adhesive with long open time and very low VOC emissions. Suitable for various tile types and substrates.
Preview Ultrabond ECO 904 Stair-Nose Adhesive Technical Data Sheet
Technical data sheet for MAPEI Ultrabond ECO 904, a water-based adhesive for bonding stair nosings to wood and concrete substrates. Includes features, application, performance properties, and contact information.
Preview MAPEI Ultrabond ECO 903: High-Performance Tongue and Groove Flooring Adhesive
Technical data sheet for MAPEI Ultrabond ECO 903, a high-performance, solvent-free acrylic latex adhesive for bonding floating wood and laminate flooring with tongue-and-groove joints. Includes application, limitations, properties, and coverage.