BERNSTEIN R18W

BERNSTEIN R18W White Steel Bathroom Towel Radiator User Manual

Model: R18W (1200x500mm)

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your BERNSTEIN R18W White Steel Bathroom Towel Radiator. Please read these instructions carefully before installation and retain them for future reference. This radiator is designed for use with standard central heating systems and can also be adapted for electric operation (electric heating element not included).

2. Safety Instructions

3. Package Contents

Please check that all components are present and undamaged before proceeding with installation.

Note: A connection kit (valves, electric heating element) is not included and must be purchased separately if required.

4. Product Overview

The BERNSTEIN R18W is a modern white steel towel radiator designed for bathrooms. It features a rectangular shape with horizontal tubes and vertical D-profiles, providing both efficient heating and a stylish appearance.

BERNSTEIN R18W towel radiator installed in a modern bathroom

Image 1: BERNSTEIN R18W towel radiator in a bathroom setting.

BERNSTEIN R18W towel radiator, front view with 1200x500mm dimensions

Image 2: Front view of the BERNSTEIN R18W radiator, highlighting its 1200x500mm dimensions.

The radiator is finished in White RAL9016 and includes a straight towel rail for added functionality.

Close-up of the straight towel rail accessory and a towel hanging on a radiator

Image 3: The included straight towel rail accessory and an example of a towel on a radiator.

5. Installation

5.1 Pre-Installation Checks

5.2 Wall Mounting

  1. Refer to the technical drawing for precise dimensions and mounting point locations.
  2. Mark the drilling points on the wall using the provided mounting brackets as a template.
  3. Drill holes and insert appropriate wall plugs (ensure they are suitable for your wall type).
  4. Secure the mounting brackets to the wall.
  5. Carefully lift the radiator and position it onto the secured brackets.
  6. Tighten any retaining screws on the brackets to firmly hold the radiator in place.
Technical drawing showing dimensions and connection points for the BERNSTEIN R18W radiator

Image 4: Technical drawing with detailed dimensions and connection options.

5.3 Plumbing Connections

The radiator offers both lateral and central connection options with G1/2" connectors. Connect the radiator to your central heating system using appropriate valves (not included). Ensure all connections are sealed properly to prevent leaks.

Close-up of the top connection point of the radiator

Image 5: Close-up view of the top connection point.

Close-up of the bottom connection points of the radiator

Image 6: Close-up view of the bottom connection points.

5.4 Filling and Bleeding

  1. Once plumbing connections are secure, slowly fill the central heating system.
  2. Open the air vent plug at the top of the radiator using a radiator key to release trapped air.
  3. Close the air vent plug once water starts to emerge steadily.
  4. Check all connections for leaks.

6. Operation

6.1 Central Heating Operation

The BERNSTEIN R18W radiator operates as part of your existing central heating system. Adjust the heat output using the radiator valves (not included) or your central heating thermostat.

6.2 Electric Operation (Optional)

This radiator can be converted for electric-only operation by installing a suitable electric heating element (not included) and filling it with a heat transfer fluid. This modification must be carried out by a qualified electrician and plumber, adhering to all electrical safety standards.

7. Maintenance

7.1 Cleaning

Clean the radiator regularly with a soft, damp cloth. For stubborn marks, a mild soap solution can be used. Rinse thoroughly and dry immediately. Avoid abrasive cleaners, scouring pads, or chemical solvents as these can damage the finish.

7.2 Bleeding the Radiator

If the top of the radiator feels cold while the bottom is hot, it indicates trapped air. Bleed the radiator as described in Section 5.4 to ensure efficient operation.

7.3 Annual Checks

Periodically check all connections for any signs of leaks or corrosion. Ensure mounting brackets remain secure.

8. Troubleshooting

ProblemPossible CauseSolution
Radiator not heating up fully (cold at top)Trapped airBleed the radiator using the air vent plug.
Radiator not heating at allValves closed, central heating system off, or system faultCheck radiator valves are open. Ensure central heating system is operational. Consult a heating engineer if system fault is suspected.
Water leaking from connectionsLoose connections or faulty sealsTighten connections (do not overtighten). Replace seals if necessary. Consult a plumber.

9. Specifications

BrandBERNSTEIN
ModelR18W
Dimensions (Height x Width)1200mm x 500mm
MaterialSteel
FinishWhite RAL9016
Horizontal TubesØ 22 mm, straight
Vertical ProfilesD-profiles: 30 x 40 mm
Connection OptionsLateral or central, G1/2" connectors
Installation MethodWall Mount
CertificationsCE certified
Included AccessoriesStraight towel rail, wall mounting kit, air vent plug, blanking plug
Connection KitNot included

10. Warranty and Support

For warranty information and customer support, please refer to the documentation provided at the point of purchase or visit the official BERNSTEIN website. Keep your proof of purchase for any warranty claims.

Related Documents - R18W

Preview Bernstein BS6002 Wall-Mounted Washbasin Installation Guide
Comprehensive instructions for the safe and correct installation of the Bernstein BS6002 wall-mounted washbasin. Includes required tools, parts list, and step-by-step mounting procedures.
Preview BERNSTEIN BS Rimless Wall Niche Installation Guide
Step-by-step assembly instructions and installation guide for the BERNSTEIN BS rimless wall niche. Learn about dimensions, mounting, tiling, and product features.
Preview Bernstein NT36 Washbasin Assembly Instructions
Comprehensive assembly instructions for the Bernstein NT36 washbasin, detailing dimensions, required tools, and step-by-step installation procedures. This guide is presented in English for clarity.
Preview Bernstein HT01 Digital Thermostat Installation and Operation Manual
This manual provides detailed instructions for the installation, setup, and operation of the Bernstein HT01 digital thermostat for underfloor heating systems. It covers technical specifications, sensor selection, programming modes, mounting procedures, electrical connections, and safety information.
Preview BERNSTEIN Dusch Pro+ Shower Toilet Operator's Manual
Comprehensive operator's manual for the BERNSTEIN Dusch Pro+ Shower Toilet. This guide provides detailed information on installation, operation, features like rear wash and lady wash, remote control functions, safety precautions, technical specifications, and troubleshooting tips for the BERNSTEIN Dusch Pro+ smart toilet.
Preview HT07 Programming Heating Thermostat User Manual | Bernstein
Comprehensive user manual for the HT07 Programming Heating Thermostat by Bernstein. Learn about installation, operation, system settings, and troubleshooting for energy-efficient heating control.