HEIMAN 633PHW
HEIMAN Interconnected Wireless Smoke Detector User Manual
Model: 633PHW
Introduction
This user manual provides detailed instructions for the installation, operation, and maintenance of your HEIMAN Interconnected Wireless Smoke Detector. This device is designed to provide early warning of smoke and fire, enhancing the safety of your home or property. Please read this manual thoroughly before use and retain it for future reference.

Image: HEIMAN Interconnected Wireless Smoke Detector. This image shows the top view of a single white, circular smoke detector with a central test button and a red LED indicator.
Safety Information
Always adhere to the following safety guidelines:
- Do not paint the smoke detector. Paint can clog the sensing chambers and prevent the alarm from operating correctly.
- Do not install in areas with high humidity, excessive dust, or near sources of combustion (e.g., kitchens, garages, bathrooms) to avoid false alarms.
- Test the smoke detector weekly to ensure proper function.
- Never ignore a smoke alarm. Investigate the cause and take appropriate action immediately.
- Keep the device clean and free from obstructions.
Product Overview
The HEIMAN Interconnected Wireless Smoke Detector features advanced photoelectric sensing technology and a 10-year sealed lithium battery for long-lasting, reliable protection. It is designed for easy installation and can wirelessly interconnect with up to 40 other compatible HEIMAN smoke detectors, ensuring that when one alarm sounds, all connected alarms will also sound.

Image: Internal view of the smoke detector with a 10-year battery icon. This image displays the internal circuitry of the smoke detector, highlighting its photoelectric sensor and the inclusion of a 10-year lithium battery.
Key Features:
- Photoelectric Sensor: Provides high-precision response to dangerous smoke.
- 10-Year Battery Life: Reduces the need for frequent battery replacements.
- Wireless Interconnection: Connects up to 40 units for comprehensive coverage.
- 85dB Alarm: Loud alarm sound to alert occupants.
- Test/Silence Button: Allows for easy testing and temporary silencing of nuisance alarms.
- LED Indicator: Provides visual status of the detector.

Image: Sensitive and Intelligent 360-degree smoke perception. This image shows the smoke detector mounted on a ceiling, with a subtle smoke effect around it, illustrating its 360-degree smoke detection capability.
Setup
1. Unpacking
Carefully remove the smoke detector and all accessories from the packaging. Verify that all components are present: smoke detector unit, mounting bracket, screws, and anchors.
2. Battery Activation
The smoke detector comes with a pre-installed 10-year lithium battery. To activate the battery, simply remove the battery isolation tab (if present) or twist the detector onto its mounting bracket. The detector will emit a short beep to indicate activation.
3. Mounting Location
Choose a central location on the ceiling or high on a wall, away from corners, vents, and direct sunlight. For optimal protection, install smoke detectors in every sleeping area and on every level of your home, including the basement.
4. Mounting the Detector
Use the provided screws and anchors to securely attach the mounting bracket to the chosen location. Once the bracket is installed, align the smoke detector with the bracket and twist it clockwise until it locks into place. Ensure it is firmly attached.
5. Wireless Interconnection
To interconnect multiple HEIMAN smoke detectors:
- On each detector, locate the DIP switches (usually inside the battery compartment or on the back).
- Set the DIP switches on all detectors you wish to interconnect to the same ID. There are 16 possible ID groups. Only detectors with matching IDs will form a connection group.
- Once the DIP switches are set, activate each detector by installing it on its mounting bracket.
- Test the interconnection by pressing the test button on one detector. All interconnected detectors should sound the alarm.
A maximum of 40 wireless smoke detectors can be interconnected. The wireless transmission range is over 150 meters in open air.

Image: Diagram illustrating the wireless interconnection of five smoke detectors. Blue dashed lines indicate the wireless communication between units.

Image: Cross-section diagram of a house with red dots indicating the placement of interconnected smoke alarms. This visual demonstrates how multiple alarms throughout a home can create a comprehensive safety network.
Operating
1. Testing the Alarm
Press and hold the large central test/silence button on the detector. The alarm will sound, and the LED indicator will flash rapidly. If interconnected, all linked alarms should also sound. Release the button to stop the test. Test your smoke detector weekly.
2. Silence Function
In case of a nuisance alarm (e.g., from cooking fumes), press the test/silence button to temporarily silence the alarm for approximately 10 minutes. The alarm will automatically reset after this period if the smoke has cleared. If smoke is still present, the alarm will reactivate.
3. LED Indicator Meanings
- Green LED (flashing every 60 seconds): Normal operation.
- Red LED (flashing rapidly with alarm): Smoke detected.
- Red LED (flashing every 60 seconds with a chirp): Low battery warning.
- Red LED (flashing every 60 seconds with a different chirp): Malfunction/fault.

Image: Close-up of the smoke detector's front face, pointing out the test button, LED indicator, and the 85dB alarm sound feature.
Maintenance
1. Cleaning
Clean your smoke detector at least once a month. Use a soft brush attachment on your vacuum cleaner to remove dust and debris from the vents. Do not use cleaning solvents or spray chemicals directly on the detector.
2. Battery Status
The detector features a 10-year sealed battery. When the battery is low, the detector will chirp approximately once every 60 seconds, accompanied by a red LED flash. Replace the entire unit when the low battery warning sounds, as the battery is not user-replaceable.
3. Regular Testing
Test your smoke detector weekly by pressing the test button. This ensures the alarm and its electronic components are functioning correctly.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Alarm chirps every 60 seconds | Low battery. | Replace the entire smoke detector unit. |
| False alarms | Cooking fumes, steam, dust, high humidity, or improper placement. | Press the silence button. Relocate the detector if false alarms persist due to environmental factors. Clean the detector. |
| Alarm does not sound during test | Battery not activated, unit malfunction, or end of life. | Ensure battery is activated. If not, replace the unit. |
| Interconnected alarms do not all sound | DIP switches not set to the same ID, or range issues. | Verify all interconnected detectors have the same DIP switch ID. Ensure detectors are within wireless range (150m open air). |
Specifications
| Feature | Specification |
|---|---|
| Model Number | 633PHW |
| Sensor Type | Photoelectric |
| Power Source | 1 CR123A Lithium Battery (sealed, 10-year life) |
| Alarm Loudness | 85 dB at 3 meters |
| Interconnection | Wireless, up to 40 units |
| Wireless Range | Over 150 meters (open air) |
| Operating Temperature | 00C to 400C (320F to 1040F) |
| Operating Humidity | Up to 95% RH (non-condensing) |
| Dimensions (L x W x H) | 15 x 15 x 5 cm |
| Certification | EN14604 |
| Material | ABS |